Automated Detection of DCIS in Whole-Slide H&E Stained Breast Histopathology Images
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper presents and evaluates a fully automatic method for detection of ductal carcinoma in situ (DCIS) in digitized hematoxylin and eosin (H&E) stained histopathological slides of breast tissue. The proposed method applies multi-scale superpixel classification to detect epithelial regions in whole-slide images (WSIs). Subsequently, spatial clustering is utilized to delineate regions representing meaningful structures within the tissue such as ducts and lobules. A region-based classifier employing a large set of features including statistical and structural texture features and architectural features is then trained to discriminate between DCIS and benign/normal structures. The system is evaluated on two datasets containing a total of 205 WSIs of breast tissue. Evaluation was conducted both on the slide and the lesion level using FROC analysis. The results show that to detect at least one true positive in every DCIS containing slide, the system finds 2.6 false positives per WSI. The results of the per-lesion evaluation show that it is possible to detect 80% and 83% of the DCIS lesions in an abnormal slide, at an average of 2.0 and 3.0 false positives per WSI, respectively. Collectively, the result of the experiments demonstrate the efficacy and accuracy of the proposed method as well as its potential for application in routine pathological diagnostics. To the best of our knowledge, this is the first DCIS detection algorithm working fully automatically on WSIs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Doyle, S., Agner, S., Madabhushi, A., Feldman, M., & Tomaszewski, J. (2008) · 2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro · doi:10.1109/isbi.2008.4541041 · Cited by 276
Cited by
Digital pathology and artificial intelligence
Niazi, M. K. K., Parwani, A. V., & Gurcan, M. N. (2019) · The Lancet Oncology · doi:10.1016/s1470-2045(19)30154-8 · Cited by 1,232
A review of the application of deep learning in medical image classification and segmentation
Cai, L., Gao, J., & Zhao, D. (2020) · Annals of Translational Medicine · doi:10.21037/atm.2020.02.44 · Cited by 587
Li, X., Li, C., Rahaman, M. M., Sun, H., Li, X., Wu, J., Yao, Y., & Grzegorzek, M. (2022) · Artificial Intelligence Review · doi:10.1007/s10462-021-10121-0 · Cited by 278
Deep learning in dermatology: a systematic review of current approaches, outcomes, and limitations
Jeong, H. K., Park, C., Henao, R., & Kheterpal, M. (2023) · JID Innovations · doi:10.1016/j.xjidi.2022.100150 · Cited by 134
Histopathological Whole Slide Image Analysis Using Context-Based CBIR
Zheng, Y., Jiang, Z., Zhang, H., Xie, F., Ma, Y., Shi, H., & Zhao, Y. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2796130 · Cited by 109
Metadata
- Authors
- Ehteshami Bejnordi, B., Balkenhol, M., Litjens, G., Holland, R., Bult, P., Karssemeijer, N., & van der Laak, J. A. W. M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2016-09
- Volume
- 35
- Issue
- 9
- Pages
- 2141-2150
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2313312719
- Cited by
- 87
- References
- 1
- FWCI
- 8.30
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated Detection of DCIS in Whole-Slide H&E Stained Breast Histopathology Images. https://app.cochat.ai/papers/10.1109/tmi.2016.2550620
- The paper
- Ehteshami Bejnordi, B., Balkenhol, M., Litjens, G., Holland, R., Bult, P., Karssemeijer, N., & van der Laak, J. A. W. M. (2016). Automated Detection of DCIS in Whole-Slide H&E Stained Breast Histopathology Images. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2016.2550620
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.