The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Adversarial Stain Transfer for Histopathology Image Analysis
Abstract
It is generally recognized that color information is central to the automatic and visual analysis of histopathology tissue slides. In practice, pathologists rely on color, which reflects the presence of specific tissue components, to establish a diagnosis. Similarly, automatic histopathology image analysis algorithms rely on color or intensity measures to extract tissue features. With the increasing access to digitized histopathology images, color variation and its implications have become a critical issue. These variations are the result of not only a variety of factors involved in the preparation of tissue slides but also in the digitization process itself. Consequently, different strategies have been proposed to alleviate stain-related tissue inconsistencies in automatic image analysis systems. Such techniques generally rely on collecting color statistics to perform color matching across images. In this work, we propose a different approach for stain normalization that we refer to as stain transfer. We design a discriminative image analysis model equipped with a stain normalization component that transfers stains across datasets. Our model comprises a generative network that learns data set-specific staining properties and image-specific color transformations as well as a task-specific network (e.g., classifier or segmentation network). The model is trained end-to-end using a multi-objective cost function. We evaluate the proposed approach in the context of automatic histopathology image analysis on three data sets and two different analysis tasks: tissue segmentation and classification. The proposed method achieves superior results in terms of accuracy and quality of normalized images compared to various baselines.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
A method for normalizing histology slides for quantitative analysis
Macenko, M., Niethammer, M., Marron, J. S., Borland, D., Woosley, J. T., Guan, X., Schmitt, C., & Thomas, N. E. (2009) · 2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro · doi:10.1109/isbi.2009.5193250 · Cited by 1,482
Image analysis and machine learning in digital pathology: challenges and opportunities
Madabhushi, A., & Lee, G. (2016) · Medical Image Analysis · doi:10.1016/j.media.2016.06.037 · Cited by 1,093
Deep learning as a tool for increased accuracy and efficiency of histopathological diagnosis
Litjens, G., Sánchez, C. I., Timofeeva, N., Hermsen, M., Nagtegaal, I., Kovacs, I., Hulsbergen - van de Kaa, C., Bult, P., van Ginneken, B., & van der Laak, J. (2016) · Scientific Reports · doi:10.1038/srep26286 · Cited by 1,069 · cited 1×
“Methods that ignore color information (i.e. (i) above) or rely on data augmentation for learning color-invariant features [16] (i.e. (ii )) generally favor texture-based features [6] but have the major limitation of ignoring clinically relevant information captured through colors.”
Background
Cited by
Data-efficient and weakly supervised computational pathology on whole-slide images
Lu, M. Y., Williamson, D. F. K., Chen, T. Y., Chen, R. J., Barbieri, M., & Mahmood, F. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00682-w · Cited by 2,282
Generative adversarial network in medical imaging: A review
Yi, X., Walia, E., & Babyn, P. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.101552 · Cited by 1,863
Digital pathology and artificial intelligence
Niazi, M. K. K., Parwani, A. V., & Gurcan, M. N. (2019) · The Lancet Oncology · doi:10.1016/s1470-2045(19)30154-8 · Cited by 1,232
Deep neural network models for computational histopathology: A survey
Srinidhi, C. L., Ciga, O., & Martel, A. L. (2021) · Medical Image Analysis · doi:10.1016/j.media.2020.101813 · Cited by 749
Salvi, M., Acharya, U. R., Molinari, F., & Meiburger, K. M. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.104129 · Cited by 386
Metadata
- Authors
- Bentaieb, A., & Hamarneh, G.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2018-03
- Volume
- 37
- Issue
- 3
- Pages
- 792-802
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2772926238
- Cited by
- 231
- References
- 5
- FWCI
- 11.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Adversarial Stain Transfer for Histopathology Image Analysis. https://app.cochat.ai/papers/10.1109/tmi.2017.2781228
- The paper
- Bentaieb, A., & Hamarneh, G. (2018). Adversarial Stain Transfer for Histopathology Image Analysis. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2017.2781228
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.