The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
DRINet for Medical Image Segmentation
Abstract
Convolutional neural networks (CNNs) have revolutionized medical image analysis over the past few years. The U-Net architecture is one of the most well-known CNN architectures for semantic segmentation and has achieved remarkable successes in many different medical image segmentation applications. The U-Net architecture consists of standard convolution layers, pooling layers, and upsampling layers. These convolution layers learn representative features of input images and construct segmentations based on the features. However, the features learned by standard convolution layers are not distinctive when the differences among different categories are subtle in terms of intensity, location, shape, and size. In this paper, we propose a novel CNN architecture, called Dense-Res-Inception Net (DRINet), which addresses this challenging problem. The proposed DRINet consists of three blocks, namely a convolutional block with dense connections, a deconvolutional block with residual inception modules, and an unpooling block. Our proposed architecture outperforms the U-Net in three different challenging applications, namely multi-class segmentation of cerebrospinal fluid on brain CT images, multi-organ segmentation on abdominal CT images, and multi-class brain tumor segmentation on MR images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
Adam: A Method for Stochastic Optimization
Kingma, D. P., & Ba, J. (2014) · arXiv · doi:10.48550/arxiv.1412.6980 · Cited by 98,946
Densely Connected Convolutional Networks
Huang, G., Liu, Z., Van Der Maaten, L., & Weinberger, K. Q. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.243 · Cited by 48,566
Going deeper with convolutions
Szegedy, C., Liu, W., Jia, Y., Sermanet, P., Reed, S., Anguelov, D., Erhan, D., Vanhoucke, V., & Rabinovich, A. (2015) · 2015 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2015.7298594 · Cited by 48,562
Batch Normalization: Accelerating Deep Network Training by Reducing Internal Covariate Shift
Ioffe, S., & Szegedy, C. (2015) · arXiv · doi:10.48550/arxiv.1502.03167 · Cited by 27,818
Chen, L.-C., Papandreou, G., Kokkinos, I., Murphy, K., & Yuille, A. L. (2016) · arXiv · doi:10.48550/arxiv.1606.00915 · Cited by 22,392
Self-citationChen, L.-C., Papandreou, G., Kokkinos, I., Murphy, K., & Yuille, A. L. (2018) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2017.2699184 · Cited by 22,392
Self-citationZhao, H., Shi, J., Qi, X., Wang, X., & Jia, J. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.660 · Cited by 16,438
3D U-Net: Learning Dense Volumetric Segmentation from Sparse Annotation
Çiçek, Ö., Abdulkadir, A., Lienkamp, S. S., Brox, T., & Ronneberger, O. (2016) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-46723-8_49 · Cited by 7,945
Cited by
U-Net and Its Variants for Medical Image Segmentation: A Review of Theory and Applications
Siddique, N., Paheding, S., Elkin, C. P., & Devabhaktuni, V. (2021) · IEEE Access · doi:10.1109/access.2021.3086020 · Cited by 1,960
DoubleU-Net: A Deep Convolutional Neural Network for Medical Image Segmentation
Jha, D., Riegler, M. A., Johansen, D., Halvorsen, P., & Johansen, H. D. (2020) · 2020 IEEE 33rd International Symposium on Computer-Based Medical Systems (CBMS) · doi:10.1109/cbms49503.2020.00111 · Cited by 819
Khened, M., Kollerathu, V. A., & Krishnamurthi, G. (2019) · Medical Image Analysis · doi:10.1016/j.media.2018.10.004 · Cited by 373
GAN Augmentation: Augmenting Training Data using Generative Adversarial Networks
Bowles, C. T., Chen, L., Guerrero, R., Bentley, P., Gunn, R. N., Hammers, A., Dickie, D. A., Hernández, M. D. C. V., Wardlaw, J. M., & Rueckert, D. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1810.10863 · Cited by 327
Self-citationDENSE-INception U-net for medical image segmentation
Zhang, Z., Wu, C., Coleman, S., & Kerr, D. (2020) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2020.105395 · Cited by 318
Metadata
- Authors
- Chen, L., Bentley, P., Mori, K., Misawa, K., Fujiwara, M., & Rueckert, D.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2018-11
- Volume
- 37
- Issue
- 11
- Pages
- 2453-2462
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2799597343
- Cited by
- 343
- References
- 41
- FWCI
- 14.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: DRINet for Medical Image Segmentation. https://app.cochat.ai/papers/10.1109/tmi.2018.2835303
- The paper
- Chen, L., Bentley, P., Mori, K., Misawa, K., Fujiwara, M., & Rueckert, D. (2018). DRINet for Medical Image Segmentation. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2018.2835303
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.