CoChat
Cited by 220

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Retinal Image Synthesis and Semi-Supervised Learning for Glaucoma Assessment

Open access
Diaz-Pinto, Andres, Colomer, Adrian, Naranjo, Valery, Morales, Sandra, Xu, Yanwu, Frangi, Alejandro F. · 2019 · IEEE Transactions on Medical Imaging

Abstract

Recent works show that generative adversarial networks (GANs) can be successfully applied to image synthesis and semi-supervised learning, where, given a small labeled database and a large unlabeled database, the goal is to train a powerful classifier. In this paper, we trained a retinal image synthesizer and a semi-supervised learning method for automatic glaucoma assessment using an adversarial model on a small glaucoma-labeled database and a large unlabeled database. Various studies have shown that glaucoma can be monitored by analyzing the optic disc and its surroundings, and for that reason, the images used in this paper were automatically cropped around the optic disc. The novelty of this paper is to propose a new retinal image synthesizer and a semi-supervised learning method for glaucoma assessment based on the deep convolutional GANs. In addition, and to the best of our knowledge, this system is trained on an unprecedented number of publicly available images (86926 images). This system, hence, is not only able to generate images synthetically but to provide labels automatically. Synthetic images were qualitatively evaluated using t-SNE plots of features associated with the images and their anatomical consistency was estimated by measuring the proportion of pixels corresponding to the anatomical structures around the optic disc. The resulting image synthesizer is able to generate realistic (cropped) retinal images, and subsequently, the glaucoma classifier is able to classify them into glaucomatous and normal with high accuracy (AUC = 0.9017). The obtained retinal image synthesizer and the glaucoma classifier could then be used to generate an unlimited number of cropped retinal images with glaucoma labels.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2019.2903434

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 220

Metadata

Authors
Diaz-Pinto, A., Colomer, A., Naranjo, V., Morales, S., Xu, Y., & Frangi, A. F.
Venue
IEEE Transactions on Medical Imaging
Published
2019-09
Volume
38
Issue
9
Pages
2211-2218
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W2921948732
Cited by
220
References
5
FWCI
14.25
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Retinal Image Synthesis and Semi-Supervised Learning for Glaucoma Assessment. https://app.cochat.ai/papers/10.1109/tmi.2019.2903434
The paper
Diaz-Pinto, A., Colomer, A., Naranjo, V., Morales, S., Xu, Y., & Frangi, A. F. (2019). Retinal Image Synthesis and Semi-Supervised Learning for Glaucoma Assessment. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2019.2903434

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.