CoChat

3D APA-Net: 3D Adversarial Pyramid Anisotropic Convolutional Network for Prostate Segmentation in MR Images

Jia, Haozhe, Xia, Yong, Song, Yang, Zhang, Donghao, Huang, Heng, Zhang, Yanning, Cai, Weidong · 2020 · IEEE Transactions on Medical Imaging
Cited by 114

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Accurate and reliable segmentation of the prostate gland using magnetic resonance (MR) imaging has critical importance for the diagnosis and treatment of prostate diseases, especially prostate cancer. Although many automated segmentation approaches, including those based on deep learning have been proposed, the segmentation performance still has room for improvement due to the large variability in image appearance, imaging interference, and anisotropic spatial resolution. In this paper, we propose the 3D adversarial pyramid anisotropic convolutional deep neural network (3D APA-Net) for prostate segmentation in MR images. This model is composed of a generator (i.e., 3D PA-Net) that performs image segmentation and a discriminator (i.e., a six-layer convolutional neural network) that differentiates between a segmentation result and its corresponding ground truth. The 3D PA-Net has an encoder-decoder architecture, which consists of a 3D ResNet encoder, an anisotropic convolutional decoder, and multi-level pyramid convolutional skip connections. The anisotropic convolutional blocks can exploit the 3D context information of the MR images with anisotropic resolution, the pyramid convolutional blocks address both voxel classification and gland localization issues, and the adversarial training regularizes 3D PA-Net and thus enables it to generate spatially consistent and continuous segmentation results. We evaluated the proposed 3D APA-Net against several state-of-the-art deep learning-based segmentation approaches on two public databases and the hybrid of the two. Our results suggest that the proposed model outperforms the compared approaches on three databases and could be used in a routine clinical workflow.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2019.2928056

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 114

Metadata

Authors
Jia, H., Xia, Y., Song, Y., Zhang, D., Huang, H., Zhang, Y., & Cai, W.
Venue
IEEE Transactions on Medical Imaging
Published
2020-02
Volume
39
Issue
2
Pages
447-457
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W2958620810
Cited by
114
References
9
FWCI
7.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: 3D APA-Net: 3D Adversarial Pyramid Anisotropic Convolutional Network for Prostate Segmentation in MR Images. https://app.cochat.ai/papers/10.1109/tmi.2019.2928056
The paper
Jia, H., Xia, Y., Song, Y., Zhang, D., Huang, H., Zhang, Y., & Cai, W. (2020). 3D APA-Net: 3D Adversarial Pyramid Anisotropic Convolutional Network for Prostate Segmentation in MR Images. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2019.2928056

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.