Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.

SACNN: Self-Attention Convolutional Neural Network for Low-Dose CT Denoising With Self-Supervised Perceptual Loss Network

Li, Meng, Hsu, William, Xie, Xiaodong, Cong, Jason, Gao, Wen · 2020 · IEEE Transactions on Medical Imaging

Abstract

Computed tomography (CT) is a widely used screening and diagnostic tool that allows clinicians to obtain a high-resolution, volumetric image of internal structures in a non-invasive manner. Increasingly, efforts have been made to improve the image quality of low-dose CT (LDCT) to reduce the cumulative radiation exposure of patients undergoing routine screening exams. The resurgence of deep learning has yielded a new approach for noise reduction by training a deep multi-layer convolutional neural networks (CNN) to map the low-dose to normal-dose CT images. However, CNN-based methods heavily rely on convolutional kernels, which use fixed-size filters to process one local neighborhood within the receptive field at a time. As a result, they are not efficient at retrieving structural information across large regions. In this paper, we propose a novel 3D self-attention convolutional neural network for the LDCT denoising problem. Our 3D self-attention module leverages the 3D volume of CT images to capture a wide range of spatial information both within CT slices and between CT slices. With the help of the 3D self-attention module, CNNs are able to leverage pixels with stronger relationships regardless of their distance and achieve better denoising results. In addition, we propose a self-supervised learning scheme to train a domain-specific autoencoder as the perceptual loss function. We combine these two methods and demonstrate their effectiveness on both CNN-based neural networks and WGAN-based neural networks with comprehensive experiments. Tested on the AAPM-Mayo Clinic Low Dose CT Grand Challenge data set, our experiments demonstrate that self-attention (SA) module and autoencoder (AE) perceptual loss function can efficiently enhance traditional CNNs and can achieve comparable or better results than the state-of-the-art methods.

Overview

Integrity signals

Registry

Crossref · 10.1109/tmi.2020.2968472

Cites

65 of 65 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 65 references

Cited by

See all 321

Metadata

Authors
Li, M., Hsu, W., Xie, X., Cong, J., & Gao, W.
Affiliations
  • Peking University (CN)
  • University of California, Los Angeles (US)
Venue
IEEE Transactions on Medical Imaging
Published
2020-07
Volume
39
Issue
7
Pages
2289-2301
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W3002137088
Cited by
321
References
65
Citations by year
2026: 26 · 2025: 49 · 2024: 60 · 2023: 70 · 2022: 61 · 2021: 48 · 2020: 7
FWCI
18.03
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Medical Imaging (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Basic Research Program of China (2016YFB0402001)
  • Beijing Major Science and Technology Project (Z191100010618003)
  • National Natural Science Foundation of China (61520106004)
  • PKU-UCLA Joint Research Institute
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Image and Signal Denoising Methods
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Image Enhancement Techniques
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
Keywords
low-dose CT, CT image denoising, self-supervised learning, perceptual loss, autoencoder, WGAN, radiation dose reduction
MeSH terms
Attention, Humans, Image Processing, Computer-Assisted, Tomography, X-Ray Computed, Neural Networks, Computer, Signal-To-Noise Ratio

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: SACNN: Self-Attention Convolutional Neural Network for Low-Dose CT Denoising With Self-Supervised Perceptual Loss Network. https://app.cochat.ai/papers/10.1109/tmi.2020.2968472
The paper
Li, M., Hsu, W., Xie, X., Cong, J., & Gao, W. (2020). SACNN: Self-Attention Convolutional Neural Network for Low-Dose CT Denoising With Self-Supervised Perceptual Loss Network. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2020.2968472

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.