SMORE: A Self-Supervised Anti-Aliasing and Super-Resolution Algorithm for MRI Using Deep Learning
Open accessAbstract
High resolution magnetic resonance (MR) images are desired in many clinical and research applications. Acquiring such images with high signal-to-noise (SNR), however, can require a long scan duration, which is difficult for patient comfort, is more costly, and makes the images susceptible to motion artifacts. A very common practical compromise for both 2D and 3D MR imaging protocols is to acquire volumetric MR images with high in-plane resolution, but lower through-plane resolution. In addition to having poor resolution in one orientation, 2D MRI acquisitions will also have aliasing artifacts, which further degrade the appearance of these images. This paper presents an approach SMORE1 based on convolutional neural networks (CNNs) that restores image quality by improving resolution and reducing aliasing in MR images.2 This approach is self-supervised, which requires no external training data because the high-resolution and low-resolution data that are present in the image itself are used for training. For 3D MRI, the method consists of only one self-supervised super-resolution (SSR) deep CNN that is trained from the volumetric image data. For 2D MRI, there is a self-supervised anti-aliasing (SAA) deep CNN that precedes the SSR CNN, also trained from the volumetric image data. Both methods were evaluated on a broad collection of MR data, including filtered and downsampled images so that quantitative metrics could be computed and compared, and actual acquired low resolution images for which visual and sharpness measures could be computed and compared. The super-resolution method is shown to be visually and quantitatively superior to previously reported methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Image quality assessment: from error visibility to structural similarity
Wang, Z., Bovik, A. C., Sheikh, H. R., & Simoncelli, E. P. (2004) · IEEE Transactions on Image Processing · doi:10.1109/tip.2003.819861 · Cited by 57,892
No-Reference Image Quality Assessment in the Spatial Domain
Mittal, A., Moorthy, A. K., & Bovik, A. C. (2012) · IEEE Transactions on Image Processing · doi:10.1109/tip.2012.2214050 · Cited by 6,064
Understanding the Effective Receptive Field in Deep Convolutional Neural Networks
Luo, W., Li, Y., Urtasun, R., & Zemel, R. (2017) · arXiv · doi:10.48550/arxiv.1701.04128 · Cited by 1,575
Cited by
Real-world single image super-resolution: A brief review
Chen, H., He, X., Qing, L., Wu, Y., Ren, C., Sheriff, R. E., & Zhu, C. (2022) · Information Fusion · doi:10.1016/j.inffus.2021.09.005 · Cited by 405
MRI Super-Resolution With Partial Diffusion Models
Zhao, K., Pang, K., Hung, A. L. Y., Zheng, H., Yan, R., & Sung, K. (2025) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2024.3483109 · Cited by 36
Metadata
- Authors
- Zhao, C., Dewey, B. E., Pham, D. L., Calabresi, P. A., Reich, D. S., & Prince, J. L.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2021-03
- Volume
- 40
- Issue
- 3
- Pages
- 805-817
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W3101204238
- Cited by
- 196
- References
- 3
- FWCI
- 8.18
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: SMORE: A Self-Supervised Anti-Aliasing and Super-Resolution Algorithm for MRI Using Deep Learning. https://app.cochat.ai/papers/10.1109/tmi.2020.3037187
- The paper
- Zhao, C., Dewey, B. E., Pham, D. L., Calabresi, P. A., Reich, D. S., & Prince, J. L. (2021). SMORE: A Self-Supervised Anti-Aliasing and Super-Resolution Algorithm for MRI Using Deep Learning. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2020.3037187
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.