Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 196

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

SMORE: A Self-Supervised Anti-Aliasing and Super-Resolution Algorithm for MRI Using Deep Learning

Open access
Zhao, Can, Dewey, Blake E., Pham, Dzung L., Calabresi, Peter A., Reich, Daniel S., Prince, Jerry L. · 2021 · IEEE Transactions on Medical Imaging

Abstract

High resolution magnetic resonance (MR) images are desired in many clinical and research applications. Acquiring such images with high signal-to-noise (SNR), however, can require a long scan duration, which is difficult for patient comfort, is more costly, and makes the images susceptible to motion artifacts. A very common practical compromise for both 2D and 3D MR imaging protocols is to acquire volumetric MR images with high in-plane resolution, but lower through-plane resolution. In addition to having poor resolution in one orientation, 2D MRI acquisitions will also have aliasing artifacts, which further degrade the appearance of these images. This paper presents an approach SMORE1 based on convolutional neural networks (CNNs) that restores image quality by improving resolution and reducing aliasing in MR images.2 This approach is self-supervised, which requires no external training data because the high-resolution and low-resolution data that are present in the image itself are used for training. For 3D MRI, the method consists of only one self-supervised super-resolution (SSR) deep CNN that is trained from the volumetric image data. For 2D MRI, there is a self-supervised anti-aliasing (SAA) deep CNN that precedes the SSR CNN, also trained from the volumetric image data. Both methods were evaluated on a broad collection of MR data, including filtered and downsampled images so that quantitative metrics could be computed and compared, and actual acquired low resolution images for which visual and sharpness measures could be computed and compared. The super-resolution method is shown to be visually and quantitatively superior to previously reported methods.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2020.3037187

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 196

Metadata

Authors
Zhao, C., Dewey, B. E., Pham, D. L., Calabresi, P. A., Reich, D. S., & Prince, J. L.
Venue
IEEE Transactions on Medical Imaging
Published
2021-03
Volume
40
Issue
3
Pages
805-817
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W3101204238
Cited by
196
References
3
FWCI
8.18
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: SMORE: A Self-Supervised Anti-Aliasing and Super-Resolution Algorithm for MRI Using Deep Learning. https://app.cochat.ai/papers/10.1109/tmi.2020.3037187
The paper
Zhao, C., Dewey, B. E., Pham, D. L., Calabresi, P. A., Reich, D. S., & Prince, J. L. (2021). SMORE: A Self-Supervised Anti-Aliasing and Super-Resolution Algorithm for MRI Using Deep Learning. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2020.3037187

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.