CoChat

Viral Pneumonia Screening on Chest X-Rays Using Confidence-Aware Anomaly Detection

Open access

The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.

Abstract

Clusters of viral pneumonia occurrences over a short period may be a harbinger of an outbreak or pandemic. Rapid and accurate detection of viral pneumonia using chest X-rays can be of significant value for large-scale screening and epidemic prevention, particularly when other more sophisticated imaging modalities are not readily accessible. However, the emergence of novel mutated viruses causes a substantial dataset shift, which can greatly limit the performance of classification-based approaches. In this paper, we formulate the task of differentiating viral pneumonia from non-viral pneumonia and healthy controls into a one-class classification-based anomaly detection problem. We therefore propose the confidence-aware anomaly detection (CAAD) model, which consists of a shared feature extractor, an anomaly detection module, and a confidence prediction module. If the anomaly score produced by the anomaly detection module is large enough, or the confidence score estimated by the confidence prediction module is small enough, the input will be accepted as an anomaly case (i.e., viral pneumonia). The major advantage of our approach over binary classification is that we avoid modeling individual viral pneumonia classes explicitly and treat all known viral pneumonia cases as anomalies to improve the one-class model. The proposed model outperforms binary classification models on the clinical X-VIRAL dataset that contains 5,977 viral pneumonia (no COVID-19) cases, 37,393 non-viral pneumonia or healthy cases. Moreover, when directly testing on the X-COVID dataset that contains 106 COVID-19 cases and 107 normal controls without any fine-tuning, our model achieves an AUC of 83.61% and sensitivity of 71.70%, which is comparable to the performance of radiologists reported in the literature.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2020.3040950

Cites

58 of 58 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 58 references

Research works printed but not linked: 1

  1. russell, 2020, Chest X-ray findings in 636 ambulatory patients with COVID-19 presenting to an urgent care center: A normal chest X-ray is no guarantee, J Urgent Care Med, 14, 8

Cited by

See all 717

Metadata

Authors
Zhang, J., Xie, Y., Pang, G., Liao, Z., Verjans, J., Li, W., Sun, Z., He, J., Li, Y., Shen, C., & Xia, Y.
Affiliations
  • Northwestern Polytechnical University (CN)
  • The University of Adelaide (AU)
  • Nanjing Drum Tower Hospital (CN)
Venue
IEEE Transactions on Medical Imaging
Published
2021-03
Volume
40
Issue
3
Pages
879-890
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W3108656121
Cited by
389
References
56
Citations by year
2026: 19 · 2025: 50 · 2024: 66 · 2023: 84 · 2022: 89 · 2021: 74
FWCI
30.91
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Medical Imaging (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • Singapore Management University Institutional Knowledge (InK) (Singapore Management University) (submittedVersion, other-oa)
  • Adelaide Research & Scholarship (AR&S) (University of Adelaide) (submittedVersion)
Funders
  • National Natural Science Foundation of China (61771397)
  • Science and Technology Innovation Committee of Shenzhen Municipality, China (JCYJ20180306171334997)
  • Innovation Foundation for Doctor Dissertation of Northwestern Polytechnical University (CX202010)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › COVID-19 diagnosis using AI
  • Physical Sciences › Computer Science › Artificial Intelligence › Anomaly Detection Techniques and Applications
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
Keywords
viral pneumonia, chest radiography, anomaly detection, one-class classification, COVID-19 detection, distribution shift
MeSH terms
Deep Learning, COVID-19, SARS-CoV-2, Humans, Pneumonia, Viral, Radiographic Image Interpretation, Computer-Assisted, Tomography, X-Ray Computed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Viral Pneumonia Screening on Chest X-Rays Using Confidence-Aware Anomaly Detection. https://app.cochat.ai/papers/10.1109/tmi.2020.3040950
The paper
Zhang, J., Xie, Y., Pang, G., Liao, Z., Verjans, J., Li, W., Sun, Z., He, J., Li, Y., Shen, C., & Xia, Y. (2021). Viral Pneumonia Screening on Chest X-Rays Using Confidence-Aware Anomaly Detection. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2020.3040950

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.