Unsupervised MRI Reconstruction via Zero-Shot Learned Adversarial Transformers
Open accessThe DOI matches its Crossref record; 91 of the 91 references it cites were found in a registry or an index.
Abstract
Supervised reconstruction models are characteristically trained on matched pairs of undersampled and fully-sampled data to capture an MRI prior, along with supervision regarding the imaging operator to enforce data consistency. To reduce supervision requirements, the recent deep image prior framework instead conjoins untrained MRI priors with the imaging operator during inference. Yet, canonical convolutional architectures are suboptimal in capturing long-range relationships, and priors based on randomly initialized networks may yield suboptimal performance. To address these limitations, here we introduce a novel unsupervised MRI reconstruction method based on zero-Shot Learned Adversarial TransformERs (SLATER). SLATER embodies a deep adversarial network with cross-attention transformers to map noise and latent variables onto coil-combined MR images. During pre-training, this unconditional network learns a high-quality MRI prior in an unsupervised generative modeling task. During inference, a zero-shot reconstruction is then performed by incorporating the imaging operator and optimizing the prior to maximize consistency to undersampled data. Comprehensive experiments on brain MRI datasets clearly demonstrate the superior performance of SLATER against state-of-the-art unsupervised methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Swin Transformer: Hierarchical Vision Transformer using Shifted Windows
Liu, Z., Lin, Y., Cao, Y., Hu, H., Wei, Y., Zhang, Z., Lin, S., & Guo, B. (2021) · 2021 IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv48922.2021.00986 · Cited by 35,534 · cited 1×
“Self-attention transformers that compute interactions among all image pixels are prohibitive at relatively high spatial resolutions [36], [76], [77].”
BackgroundGenerative adversarial networks
Goodfellow, I., Pouget-Abadie, J., Mirza, M., Xu, B., Warde-Farley, D., Ozair, S., Courville, A., & Bengio, Y. (2020) · Communications of the ACM · doi:10.1145/3422622 · Cited by 18,384
A Style-Based Generator Architecture for Generative Adversarial Networks
Karras, T., Laine, S., & Aila, T. (2019) · 2019 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2019.00453 · Cited by 11,714 · cited 1×
“architecture that allows improved control of image features across the network [64], [65].”
BackgroundPattern Recognition and Machine Learning
(2006) · doi:10.1007/978-0-387-45528-0 · Cited by 9,824
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952 · cited 2×
“The regularization term can be designed based on sparsity priors [3], [4], structured low-rank priors [71], [72], or network priors [6].”
BackgroundMethodAnalyzing and Improving the Image Quality of StyleGAN
Karras, T., Laine, S., Aittala, M., Hellsten, J., Lehtinen, J., & Aila, T. (2020) · 2020 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr42600.2020.00813 · Cited by 6,332
Analyzing and Improving the Image Quality of StyleGAN
Karras, T., Laine, S., Aittala, M., Hellsten, J., Lehtinen, J., & Aila, T. (2019) · arXiv · doi:10.48550/arxiv.1912.04958 · Cited by 6,332
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251 · cited 1×
“images from available k-space data [1]–[4].”
Attention U-Net: Learning Where to Look for the Pancreas
Oktay, O., Schlemper, J., Folgoc, L. L., Lee, M., Heinrich, M., Misawa, K., Mori, K., McDonagh, S., Hammerla, N. Y., Kainz, B., et al. (2018) · arXiv · doi:10.48550/arxiv.1804.03999 · Cited by 5,458
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
Cited by
Transformers in medical imaging: A survey
Shamshad, F., Khan, S., Zamir, S. W., Khan, M. H., Hayat, M., Khan, F. S., & Fu, H. (2023) · Medical Image Analysis · doi:10.1016/j.media.2023.102802 · Cited by 1,296
Diffusion models in medical imaging: A comprehensive survey
Kazerouni, A., Aghdam, E. K., Heidari, M., Azad, R., Fayyaz, M., Hacihaliloglu, I., & Merhof, D. (2023) · Medical Image Analysis · doi:10.1016/j.media.2023.102846 · Cited by 765
ResViT: Residual Vision Transformers for Multimodal Medical Image Synthesis
Dalmaz, O., Yurt, M., & Cukur, T. (2022) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2022.3167808 · Cited by 597
Self-citationUnsupervised Medical Image Translation With Adversarial Diffusion Models
Özbey, M., Dalmaz, O., Dar, S. U. H., Bedel, H. A., Özturk, Ş., Güngör, A., & Çukur, T. (2023) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2023.3290149 · Cited by 517
Self-citationAdvances in medical image analysis with vision Transformers: A comprehensive review
Azad, R., Kazerouni, A., Heidari, M., Aghdam, E. K., Molaei, A., Jia, Y., Jose, A., Roy, R., & Merhof, D. (2024) · Medical Image Analysis · doi:10.1016/j.media.2023.103000 · Cited by 485
Transformers in medical image analysis
He, K., Gan, C., Li, Z., Rekik, I., Yin, Z., Ji, W., Gao, Y., Wang, Q., Zhang, J., & Shen, D. (2023) · Intelligent Medicine · doi:10.1016/j.imed.2022.07.002 · Cited by 475
Soviany, P., Ionescu, R. T., Rota, P., & Sebe, N. (2022) · International Journal of Computer Vision · doi:10.1007/s11263-022-01611-x · Cited by 431
Li, J., Chen, J., Tang, Y., Wang, C., Landman, B. A., & Zhou, S. K. (2023) · Medical Image Analysis · doi:10.1016/j.media.2023.102762 · Cited by 389
Deep Learning Attention Mechanism in Medical Image Analysis: Basics and Beyonds
Li, X., Li, M., Yan, P., Li, G., Jiang, Y., Luo, H., & Yin, S. (2023) · International Journal of Network Dynamics and Intelligence · doi:10.53941/ijndi0201006 · Cited by 269
Adaptive diffusion priors for accelerated MRI reconstruction
Güngör, A., Dar, S. U., Öztürk, Ş., Korkmaz, Y., Bedel, H. A., Elmas, G., Ozbey, M., & Çukur, T. (2023) · Medical Image Analysis · doi:10.1016/j.media.2023.102872 · Cited by 246
“A common approach rests on generative adversarial networks (GANs) that indirectly characterize the data distribution (Narnhofer et al., 2019; Liu et al., 2020; Korkmaz et al., 2022; Elmas et al., 2022).”
BackgroundMethodInfluentialSelf-citationTransformers and large language models in healthcare: A review
Nerella, S., Bandyopadhyay, S., Zhang, J., Contreras, M., Siegel, S., Bumin, A., Silva, B., Sena, J., Shickel, B., Bihorac, A., et al. (2024) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2024.102900 · Cited by 197
“Korkmaz et al. proposed a MRI reconstruction model based on zero-shot learned adversarial vision Transformer named SLATER [319] to overcome the limitation of data size.”
Celard, P., Iglesias, E. L., Sorribes-Fdez, J. M., Romero, R., Vieira, A. S., & Borrajo, L. (2023) · Neural Computing and Applications · doi:10.1007/s00521-022-07953-4 · Cited by 188
Multimodal Transformer for Accelerated MR Imaging
Feng, C.-M., Yan, Y., Chen, G., Xu, Y., Hu, Y., Shao, L., & Fu, H. (2023) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2022.3180228 · Cited by 183
“used the cross attention module to capture interactions between latent variables and image features with a deep adversarial network to solve the unsupervised MRI reconstruction problem [31].”
MethodM3T: three-dimensional Medical image classifier using Multi-plane and Multi-slice Transformer
Jang, J., & Hwang, D. (2022) · 2022 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr52688.2022.02006 · Cited by 133
Metadata
- Authors
- Korkmaz, Y., Dar, S. U. H., Yurt, M., Ozbey, M., & Cukur, T.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2022-07
- Volume
- 41
- Issue
- 7
- Pages
- 1747-1763
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W3161035636
- Cited by
- 231
- References
- 91
- FWCI
- 26.90
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.