Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 182

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Dual Encoder-Based Dynamic-Channel Graph Convolutional Network With Edge Enhancement for Retinal Vessel Segmentation

Li, Yang, Zhang, Yue, Cui, Weigang, Lei, Baiying, Kuang, Xihe, Zhang, Teng·2022·IEEE Transactions on Medical Imaging

Abstract

Retinal vessel segmentation with deep learning technology is a crucial auxiliary method for clinicians to diagnose fundus diseases. However, the deep learning approaches inevitably lose the edge information, which contains spatial features of vessels while performing down-sampling, leading to the limited segmentation performance of fine blood vessels. Furthermore, the existing methods ignore the dynamic topological correlations among feature maps in the deep learning framework, resulting in the inefficient capture of the channel characterization. To address these limitations, we propose a novel dual encoder-based dynamic-channel graph convolutional network with edge enhancement (DE-DCGCN-EE) for retinal vessel segmentation. Specifically, we first design an edge detection-based dual encoder to preserve the edge of vessels in down-sampling. Secondly, we investigate a dynamic-channel graph convolutional network to map the image channels to the topological space and synthesize the features of each channel on the topological map, which solves the limitation of insufficient channel information utilization. Finally, we study an edge enhancement block, aiming to fuse the edge and spatial features in the dual encoder, which is beneficial to improve the accuracy of fine blood vessel segmentation. Competitive experimental results on five retinal image datasets validate the efficacy of the proposed DE-DCGCN-EE, which achieves more remarkable segmentation results against the other state-of-the-art methods, indicating its potential clinical application.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2022.3151666

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 182

Metadata

Authors
Li, Y., Zhang, Y., Cui, W., Lei, B., Kuang, X., & Zhang, T.
Venue
IEEE Transactions on Medical Imaging
Published
2022-08
Volume
41
Issue
8
Pages
1975-1989
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W4212852978
Cited by
182
References
8
FWCI
19.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dual Encoder-Based Dynamic-Channel Graph Convolutional Network With Edge Enhancement for Retinal Vessel Segmentation. https://app.cochat.ai/papers/10.1109/tmi.2022.3151666
The paper
Li, Y., Zhang, Y., Cui, W., Lei, B., Kuang, X., & Zhang, T. (2022). Dual Encoder-Based Dynamic-Channel Graph Convolutional Network With Edge Enhancement for Retinal Vessel Segmentation. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2022.3151666

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.