CoChat

Federated Learning of Generative Image Priors for MRI Reconstruction

Open access
Elmas, Gokberk, Dar, Salman U. H., Korkmaz, Yilmaz, Ceyani, Emir, Susam, Burak, Ozbey, Muzaffer, Avestimehr, Salman, Çukur, Tolga · 2023 · IEEE Transactions on Medical Imaging
Cited by 115

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

Multi-institutional efforts can facilitate training of deep MRI reconstruction models, albeit privacy risks arise during cross-site sharing of imaging data. Federated learning (FL) has recently been introduced to address privacy concerns by enabling distributed training without transfer of imaging data. Existing FL methods employ conditional reconstruction models to map from undersampled to fully-sampled acquisitions via explicit knowledge of the accelerated imaging operator. Since conditional models generalize poorly across different acceleration rates or sampling densities, imaging operators must be fixed between training and testing, and they are typically matched across sites. To improve patient privacy, performance and flexibility in multi-site collaborations, here we introduce Federated learning of Generative IMage Priors (FedGIMP) for MRI reconstruction. FedGIMP leverages a two-stage approach: cross-site learning of a generative MRI prior, and prior adaptation following injection of the imaging operator. The global MRI prior is learned via an unconditional adversarial model that synthesizes high-quality MR images based on latent variables. A novel mapper subnetwork produces site-specific latents to maintain specificity in the prior. During inference, the prior is first combined with subject-specific imaging operators to enable reconstruction, and it is then adapted to individual cross-sections by minimizing a data-consistency loss. Comprehensive experiments on multi-institutional datasets clearly demonstrate enhanced performance of FedGIMP against both centralized and FL methods based on conditional models.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2022.3220757

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 115

Metadata

Authors
Elmas, G., Dar, S. U. H., Korkmaz, Y., Ceyani, E., Susam, B., Ozbey, M., Avestimehr, S., & Çukur, T.
Venue
IEEE Transactions on Medical Imaging
Published
2023-07
Volume
42
Issue
7
Pages
1996-2009
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W4308637617
Cited by
115
References
17
FWCI
12.49
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Federated Learning of Generative Image Priors for MRI Reconstruction. https://app.cochat.ai/papers/10.1109/tmi.2022.3220757
The paper
Elmas, G., Dar, S. U. H., Korkmaz, Y., Ceyani, E., Susam, B., Ozbey, M., Avestimehr, S., & Çukur, T. (2023). Federated Learning of Generative Image Priors for MRI Reconstruction. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2022.3220757

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.