Cited by 12EEG and Brain-Computer InterfacesEmotion and Mood RecognitionGaze Tracking and Assistive Technology

Calibration-Free Error-Related Potential Decoding With Adaptive Subject-Independent Models: A Comparative Study

Schönleitner, Florian M., Otter, Lukas, Ehrlich, Stefan K., Cheng, Gordon·2020·IEEE Transactions on Medical Robotics and Bionics

Abstract

Error-related potentials (ErrPs) provide an elegant method to improve human-machine interaction by detecting incorrect system behavior from the electroencephalogram of a human operator in real time. In this paper, we focus on adaptive subject-independent decoding models particularly suitable for ErrP classification. As individualized decoding models require a time-consuming calibration phase, such models provide a promising alternative. Based on an investigation of the characteristics of inter-subject variations in the signal and feature space, we evaluate the performance of a decoding model solely trained on prior data and the effectiveness of adapting this model to a new subject in a comparative study. Our results show that such a generalized model can decode ErrPs with an acceptable average accuracy of 72.7 ± 9.66% and that supervised adaptation can significantly improve the accuracy of the generalized model after adaptation with 85 trials by on average +3.8 ± 5.1%. We show that adaptation of subject-independent decoding models is superior to the traditional calibration procedure. Unsupervised adaptation only proved effective for some subjects and requires further attention to be practical for a broader range of subjects. Consequently, our work contributes to the development of calibration-free ErrP decoding in the broader scope of enhancing usability of ErrPs for human-machine interaction.

Integrity signals

Registry

Crossref · 10.1109/tmrb.2020.3012436

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Calibration-free cross-subject ErrP classification has been demonstrated with generalized LDA, an xDAWN+RG pipeline with a support vector machine classifier, ensemble classifiers, and online PCA-based pipelines, though without inherent interpretability.

    “Calibration-free cross-subject ErrP classification has been demonstrated with generalized LDA [16], an xDAWN+RG pipeline with a support vector machine classifier [17], ensemble classifiers [18], and online PCA-based pipelines [19], though without inherent interpretability.”
  • On HRI, Sch ̈ onleitner et al. [16] reported 72.7% balanced accuracy with generalized LDA using 27 channels; ERP-XTTN achieved 76.6% with three midline channels.

    “On HRI, Sch¨ onleitner et al. [16] reported 72.7% balanced accuracy with generalized LDA using 27 channels; ERP-XTTN achieved 76.6% with three midline channels.”
  • All results reported here use causal IIR filtering under calibration-free LOSO evaluation; many published LOSO benchmarks use acausal filtering instead, so their reported performance is not reproducible in a forward-processing pipeline.

    “All results reported here use causal IIR filtering under calibration-free LOSO evaluation; many published LOSO benchmarks use acausal filtering instead [9], [16], so their reported performance is not reproducible in a forward-processing pipeline.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Schönleitner, F. M., Otter, L., Ehrlich, S. K., & Cheng, G.
Affiliations
Technical University of Munich (DE)
Venue
IEEE Transactions on Medical Robotics and Bionics
Published
2020-08
Volume
2
Issue
3
Pages
399-409
ISSN
2576-3202 (ISSN-L)
OpenAlex
W3046817909
Cited by
12
References
4
Citations by year
2026: 1 · 2024: 3 · 2022: 2 · 2021: 3 · 2020: 3
FWCI
1.08
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Medical Robotics and Bionics (publishedVersion)
Funders
  • Elite Master Program in Neuroengineering at the Technische Universität München
  • Elite Network Bavaria
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Emotion and Mood Recognition
  • Physical Sciences › Computer Science › Human-Computer Interaction › Gaze Tracking and Assistive Technology
Keywords
error-related potentials, adaptive decoding, supervised adaptation, unsupervised adaptation, interindividual variability, EEG, human-machine interaction, brain-computer interface, error detection

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review