Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 31 of the 32 references it cites were found in a registry or an index.

Unsupervised Brain Computer Interface Based on Intersubject Information and Online Adaptation

Lu, Shijian, Guan, Cuntai, Zhang, Haihong · 2009 · IEEE Transactions on Neural Systems and Rehabilitation Engineering

Abstract

Conventional brain computer interfaces rely on a guided calibration procedure to address the problem of considerable variations in electroencephalography (EEG) across human subjects. This calibration, however, implies inconvenience to the end users. In this paper, we propose an online-adaptive-learning method to address this problem for P300-based brain computer interfaces. By automatically capturing subject-specific EEG characteristics during online operation, this method allows a new user to start operating a P300-based brain-computer interface without guided (supervised) calibration. The basic principle is to first learn a generic model termed subject-independent model offline from EEG of a pool of subjects to capture common P300 characteristics. For a new user, a new model termed subject-specific model is then adapted online based on EEG recorded from the new subject and the corresponding labels predicted by either the subject-independent model or the adapted subject-specific model, depending on a confidence score. To verify the proposed method, a study involving 10 healthy subjects is carried out and positive results are obtained. For instance, after 2-4 min online adaptation (spelling of 10-20 characters), the accuracy of the adapted model converges to that of a fully trained supervised subject-specific model.

Overview

Integrity signals

Registry

Crossref · 10.1109/tnsre.2009.2015197

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 32 references

Cited by

See all 122

Metadata

Authors
Lu, S., Guan, C., & Zhang, H.
Affiliations
Institute for Infocomm Research (SG)
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2009-04
Volume
17
Issue
2
Pages
135-145
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2141333870
Cited by
122
References
32
Citations by year
2025: 1 · 2023: 3 · 2022: 1 · 2021: 6 · 2020: 16 · 2019: 6 · 2018: 8 · 2017: 5 · 2016: 10 · 2015: 13 · 2014: 14 · 2013: 14 · 2012: 6
FWCI
4.03
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
  • Physical Sciences › Computer Science › Human-Computer Interaction › Gaze Tracking and Assistive Technology
  • Physical Sciences › Computer Science › Artificial Intelligence › Emotion and Mood Recognition
Keywords
brain-computer interface, P300, unsupervised calibration, online adaptation, subject-specific modeling, EEG
MeSH terms
Algorithms, Brain, Calibration, Data Collection, Electroencephalography, Humans, Online Systems, Reference Values, User-Computer Interface, Reproducibility of Results, Models, Statistical, Event-Related Potentials, P300

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Unsupervised Brain Computer Interface Based on Intersubject Information and Online Adaptation. https://app.cochat.ai/papers/10.1109/tnsre.2009.2015197
The paper
Lu, S., Guan, C., & Zhang, H. (2009). Unsupervised Brain Computer Interface Based on Intersubject Information and Online Adaptation. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2009.2015197

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.