Penetrating 3-D Imaging at 4- and 25-m Range Using a Submillimeter-Wave Radar
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
We show experimentally that a high-resolution imaging radar operating at 576-605 GHz is capable of detecting weapons concealed by clothing at standoff ranges of 4-25 m. We also demonstrate the critical advantage of 3-D image reconstruction for visualizing hidden objects using active-illumination coherent terahertz imaging. The present system can image a torso with <1 cm resolution at 4 m standoff in about five minutes. Greater standoff distances and much higher frame rates should be achievable by capitalizing on the bandwidth, output power, and compactness of solid state Schottky-diode based terahertz mixers and multiplied sources.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1999) · Sensor Review · doi:10.1108/sr.1999.08719bae.001 · Cited by 6,021
Standoff Detection of Weapons and Contraband in the 100 GHz to 1 THz Region
Appleby, R., & Wallace, H. B. (2007) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2007.908543 · Cited by 575
600 GHz Imaging Radar with 2 cm Range Resolution
Dengler, R. J., Cooper, K. B., Chattopadhyay, G., Mehdi, I., Schlecht, E. T., Skalare, A. J., Chen, C., & Siegel, P. H. (2007) · IEEE MTT-S International Microwave Symposium digest · doi:10.1109/mwsym.2007.380468 · Cited by 68
Self-citation
Cited by
THz Imaging Radar for Standoff Personnel Screening
Cooper, K. B., Dengler, R. J., Llombart, N., Thomas, B., Chattopadhyay, G., & Siegel, P. H. (2011) · IEEE Transactions on Terahertz Science and Technology · doi:10.1109/tthz.2011.2159556 · Cited by 840
Self-citationToward real-time terahertz imaging
Guerboukha, H., Nallappan, K., & Skorobogatiy, M. (2018) · Advances in Optics and Photonics · doi:10.1364/aop.10.000843 · Cited by 467
Capturing the human figure through a wall
Adib, F., Hsu, C.-Y., Mao, H., Katabi, D., & Durand, F. (2015) · ACM Transactions on Graphics · doi:10.1145/2816795.2818072 · Cited by 443
“The first category is high-frequency imaging radar using terahertz [Woodward et al. 2002], laser [Allen et al. 2003], or millimeter and sub-millimeter waves [Cooper et al. 2008; Dengler et al. 2007; Appleby and An-derton 2007].”
MethodTerahertz Imaging and Sensing Applications With Silicon-Based Technologies
Hillger, P., Grzyb, J., Jain, R., & Pfeiffer, U. R. (2019) · IEEE Transactions on Terahertz Science and Technology · doi:10.1109/tthz.2018.2884852 · Cited by 408
Ahmed, S. S., Schiessl, A., Gumbmann, F., Tiebout, M., Methfessel, S., & Schmidt, L.-P. (2012) · IEEE Microwave Magazine · doi:10.1109/mmm.2012.2205772 · Cited by 326
Metadata
- Authors
- Cooper, K. B., Dengler, R. J., Llombart, N., Bryllert, T., Chattopadhyay, G., Schlecht, E., Gill, J., Lee, C., Skalare, A., Mehdi, I., & Siegel, P. H.
- Venue
- IEEE Transactions on Microwave Theory and Techniques
- Published
- 2008-12
- Volume
- 56
- Issue
- 12
- Pages
- 2771-2778
- ISSN
- 0018-9480 (ISSN-L)
- 1557-9670
- OpenAlex
- W2150558863
- Cited by
- 360
- References
- 3
- FWCI
- 18.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.