Assessment of Heart Rate Variability and Respiratory Sinus Arrhythmia via Doppler Radar
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
An investigation of heart rate variability (HRV) and respiratory sinus arrhythmia (RSA) indices using data obtained from Doppler radar cardiopulmonary remote sensing is presented in this paper. High accuracy in extracting the HRV and RSA indices was achieved using a direct-conversion quadrature radar system with linear demodulation method. This method was validated using data obtained from 12 human subjects in seated and supine positions. For supine position measurements, all standard deviation of normal beat-to-beat interval indices from Doppler radar and electrocardiogram reference differed less than$\pm$9 ms of each other, while all the root mean square of differences of successive normal beat-to-beat interval indices differed less than$\pm$76 ms. The measurements from subjects in seated and supine positions with normal RSA demonstrated that the results from radar correlated well with both respiratory piezoresistor chest belts. Higher level of HRV and RSA was detected in seated position, as expected.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Multifractality in human heartbeat dynamics
Ivanov, P. C., Amaral, L. A. N., Goldberger, A. L., Havlin, S., Rosenblum, M. G., Struzik, Z. R., & Stanley, H. E. (1999) · Nature · doi:10.1038/20924 · Cited by 1,456 · cited 1×
“Medical research has associated lowered HRV with aging, decreased autonomic activity, sleep apnea, diabetic neuropathy, and increased risk of sudden cardiac death after acute myocardial infarction (MI) [ 2 ]–[6].”
BackgroundMultifractality in Human Heartbeat Dynamics.
Ivanov, P. C., Amaral, L. A. N., Goldberger, A. L., Havlin, S., Rosenblum, M. G., Struzik, Z. R., & Stanley, E. (1999) · Centrum Wiskunde & Informatica (CWI), the national research institute for mathematics and computer science in the Netherlands · Cited by 1,327
Arctangent Demodulation With DC Offset Compensation in Quadrature Doppler Radar Receiver Systems
Park, B.-K., Boric-Lubecke, O., & Lubecke, V. M. (2007) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2007.895653 · Cited by 604
Self-citationStauss, H. M. (2003) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00452.2003 · Cited by 318
Microwave sensing of physiological movement and volume change: A review
Lin, J. C. (1992) · Bioelectromagnetics · doi:10.1002/bem.2250130610 · Cited by 299 · cited 1×
“The measurements from subjects in seated and supine positions with normal RSA demonstrated that the results from radar correlated well with both respiratory piezoresistor chest belts.”
MethodBilchick, K. C., Fetics, B., Djoukeng, R., Gross Fisher, S., Fletcher, R. D., Singh, S. N., Nevo, E., & Berger, R. D. (2002) · The American Journal of Cardiology · doi:10.1016/s0002-9149(02)02380-9 · Cited by 288 · cited 1×
“acute MI followed by sudden cardiac death [6].”
BackgroundLaser monitoring of chest wall displacement
Kondo, T., Uhlig, T., Pemberton, P. J., & Sly, P. D. (1997) · European Respiratory Journal · doi:10.1183/09031936.97.10081865 · Cited by 141
Malliani, A., Pagani, M., Furlan, R., Guzzetti, S., Lucini, D., Montano, N., Cerutti, S., & Mela, G. S. (1997) · Circulation · doi:10.1161/01.cir.96.12.4143 · Cited by 113
Hilton, M. F., Bates, R., Godfrey, K. R., Chappell, M. J., & Cayton, R. M. (1999) · Medical & Biological Engineering & Computing · doi:10.1007/bf02513379 · Cited by 112
Current clinical applications of heart rate variability
Stys, A., & Stys, T. (1998) · Clinical Cardiology · doi:10.1002/clc.4960211005 · Cited by 109
McCabe, P. M., Yongue, B. G., Ackles, P. K., & Porges, S. W. (1985) · Psychophysiology · doi:10.1111/j.1469-8986.1985.tb01585.x · Cited by 70 · cited 1×
“Multiple pharmacological studies suggest that HRV is a useful indicator to quantitatively measure physiological changes during treatment [7], [ 8 ].”
BackgroundShort-term heart rate variability during a cognitive challenge in young and older adults
Wood, R., Maraj, B., Lee, C. M., & Reyes, R. (2002) · Age and Ageing · doi:10.1093/ageing/31.2.131 · Cited by 56
Massagram, W., Hafner, N. M., Park, B.-K., Lubecke, V. M., Høst-Madsen, A., & Borić-Lubecke, O. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352622 · Cited by 56 · cited 1×
“She is now with the Faculty of Science, Department of Computer Science and Information Technology, Naresuan University, Phitsanulok 65000, Thailand (e-mail: wansureem@nu.ac. th).”
BackgroundSelf-citationHeart Rate Variability Assessment Using Doppler Radar with Linear Demodulation
Borić-Lubecke, O., Massagram, W., Lubecke, V. M., Høst-Madsen, A., & Jokanovic, B. S. (2008) · European Microwave Conference (EuMC) · doi:10.1109/eumc.2008.4751478 · Cited by 32 · cited 2×
“…over cycles of 5 h or more; 2) temperature regulation, which varies with about 25-s cycles; 3) cardiac sympathetic (fight and flight) nervous activity, which varies with about 6-s cycles; and 4) synchronization with respiratory rhythm, which varies the beat-to-beat intervals with each breath [1].”
BackgroundSelf-citationEffects of combination psychotropic drug treatment on heart rate variability in psychiatric patients
Ikawa, M., Tabuse, H., Ueno, S., Urano, T., Sekiya, M., & Murakami, T. (2001) · Psychiatry and Clinical Neurosciences · doi:10.1046/j.1440-1819.2001.00873.x · Cited by 15
Feasibility of HRV measurement from single-channel doppler radar
Massagram, W., Hafner, N. M., Yamada, S., Lubecke, V. M., & Boric-Lubecke, O. (2007) · Digest - IEEE Antennas and Propagation Society. International Symposium · doi:10.1109/aps.2007.4395482 · Cited by 7 · cited 1×
“radar has potential to provide a practical tool for HRV assessment [9]–[11].”
MethodSelf-citation
Cited by
Emotion recognition using wireless signals
Zhao, M., Adib, F., & Katabi, D. (2016) · Proceedings of the 22nd Annual International Conference on Mobile Computing and Networking · doi:10.1145/2973750.2973762 · Cited by 461
“• The paper also presents a user study of the accuracy of emotion recognition using RF reflections, and an empirical comparison with both ECG-based and image-based emotion recognition systems.”
MethodHu, W., Zhao, Z., Wang, Y., Zhang, H., & Lin, F. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2288319 · Cited by 247
Metadata
- Authors
- Massagram, W., Lubecke, V. M., Host-Madsen, A., & Boric-Lubecke, O.
- Venue
- IEEE Transactions on Microwave Theory and Techniques
- Published
- 2009-10
- Volume
- 57
- Issue
- 10
- Pages
- 2542-2549
- ISSN
- 0018-9480 (ISSN-L)
- 1557-9670
- OpenAlex
- W2171942582
- Cited by
- 180
- References
- 18
- FWCI
- 2.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.