The DOI matches its Crossref record.
Microwave sensing of physiological movement and volume change: A review
Abstract
The ability non‐invasively to detect and monitor the movement of tissues and organs from outside the body provides many worthwhile areas of potential biomedical applications. Several non‐invasive microwave techniques for contact and remote sensing of circulatory and respiratory movements and volume changes have been developed. In general, these systems consist of a microwave generator, a sampling device, a transmitting‐receiving antenna, a set of signal‐conditioning and processing devices, and a display unit. They operate at continuous‐wave frequencies between 1 and 35 GHz and make use of amplitude and phase information derived from the received signal. The average power density of energy radiated by present systems ranges from approximately 0.001–1.0 mW/cm 2. These systems are capable of registering instantaneous changes in fluid volume, pressure pulse, heart rate, and respiration rate in contact with body surface or at distances greater than 30 m, or behind thick layers of non‐conductive walls. 1992 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Random Body Movement Cancellation in Doppler Radar Vital Sign Detection
Li, C., & Lin, J. (2008) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2008.2007139 · Cited by 448
Self-citationSignal-to-Noise Ratio in Doppler Radar System for Heart and Respiratory Rate Measurements
Droitcour, A. D., Boric-Lubecke, O., & Kovacs, G. T. A. (2009) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2009.2029668 · Cited by 162
Seismocardiogram and Ballistocardiogram Sensing
Postolache, O., Girão, P., & Postolache, G. (2013) · Advanced Instrument Engineering · doi:10.4018/978-1-4666-4165-5.ch017 · Cited by 5
Metadata
- Authors
- Lin, J. C.
- Venue
- Bioelectromagnetics
- Publisher
- Wiley
- Published
- 1992-01
- Volume
- 13
- Issue
- 6
- Pages
- 557-565
- ISSN
- 0197-8462 (ISSN-L)
- 1521-186X
- OpenAlex
- W2038323669
- Cited by
- 299
- References
- 0
- FWCI
- 0.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microwave sensing of physiological movement and volume change: A review. https://app.cochat.ai/papers/10.1002/bem.2250130610
- The paper
- Lin, J. C. (1992). Microwave sensing of physiological movement and volume change: A review. Bioelectromagnetics. https://doi.org/10.1002/bem.2250130610
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.