The DOI matches its Crossref record.
Analysis of an Indoor Biomedical Radar-Based System for Health Monitoring
Open accessAbstract
Innovative technology approaches have been increasingly investigated for the last two decades aiming at human-being long-term monitoring. However, current solutions suffer from critical limitations. In this paper, a complete system for contactless health-monitoring in home environment is presented. For the first time, radar, wireless communications, and data processing techniques are combined, enabling contactless fall detection and tagless localization. Practical limitations are considered and properly dealt with. Experimental tests, conducted with human volunteers in a realistic room setting, demonstrate an adequate detection of the target's absolute distance and a success rate of 94.3% in distinguishing fall events from normal movements. The volunteers were free to move about the whole room with no constraints in their movements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Review on Recent Progress of Portable Short-Range Noncontact Microwave Radar Systems
Li, C., Peng, Z., Huang, T.-Y., Fan, T., Wang, F.-K., Horng, T.-S., Munoz-Ferreras, J.-M., Gomez-Garcia, R., Ran, L., & Lin, J. (2017) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2017.2650911 · Cited by 372
Vital-sign monitoring and spatial tracking of multiple people using a contactless radar-based sensor
Mercuri, M., Lorato, I. R., Liu, Y.-H., Wieringa, F., Hoof, C. V., & Torfs, T. (2019) · Nature Electronics · doi:10.1038/s41928-019-0258-6 · Cited by 354
Self-citationWearable Wireless Health Monitoring: Current Developments, Challenges, and Future Trends
Soh, P. J., Vandenbosch, G. A. E., Mercuri, M., & Schreurs, D. M. M.-P. (2015) · IEEE Microwave Magazine · doi:10.1109/mmm.2015.2394021 · Cited by 253
Self-citation
Metadata
- Authors
- Mercuri, M., Soh, P. J., Pandey, G., Karsmakers, P., Vandenbosch, G. A. E., Leroux, P., & Schreurs, D.
- Venue
- IEEE Transactions on Microwave Theory and Techniques
- Published
- 2013-05
- Volume
- 61
- Issue
- 5
- Pages
- 2061-2068
- ISSN
- 0018-9480 (ISSN-L)
- 1557-9670
- OpenAlex
- W2017194250
- Cited by
- 173
- References
- 0
- FWCI
- 9.39
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analysis of an Indoor Biomedical Radar-Based System for Health Monitoring. https://app.cochat.ai/papers/10.1109/tmtt.2013.2247619
- The paper
- Mercuri, M., Soh, P. J., Pandey, G., Karsmakers, P., Vandenbosch, G. A. E., Leroux, P., & Schreurs, D. (2013). Analysis of an Indoor Biomedical Radar-Based System for Health Monitoring. IEEE Transactions on Microwave Theory and Techniques. https://doi.org/10.1109/tmtt.2013.2247619
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.