Comparative Study of Acoustic Wave Devices Using Thin Piezoelectric Plates in the 3–5-GHz Range
The DOI matches its Crossref record.
Abstract
This paper investigates the applicability of acoustic wave devices using an interdigital transducer placed on a thin piezoelectric crystal plate to the 3-5-GHz range, where significant performance degradation was expected in surface acoustic wave (SAW) devices. Three types of the SAW-like devices were fabricated by using a KrF stepper/scanner, and their performances are compared from various aspects: 1) a 3.5-GHz resonator using a rotated V-cut LiTaO3plate attached on a Si substrate; 2) a 5-GHz resonator using a X-cut LiNbO3plate on a Si substrate; and 3) a 5.4-GHz A1Lamb mode resonator on a free-standing Z-cut LiNbO3plate. It is revealed that these devices offer excellent performances even in the 3-5-GHz range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Suppression of Transverse Modes in 50°YX-LiTaO3/SiO2/Si POI SAW Resonator with Groove Configuration
Li, M., Qi, M., Chen, Y., Cheng, Y., Cao, L., & Mu, X. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c07223 · Cited by 6
Metadata
- Authors
- Kimura, T., Omura, M., Kishimoto, Y., & Hashimoto, K.
- Venue
- IEEE Transactions on Microwave Theory and Techniques
- Published
- 2019-03
- Volume
- 67
- Issue
- 3
- Pages
- 915-921
- ISSN
- 0018-9480 (ISSN-L)
- 1557-9670
- OpenAlex
- W2909724177
- Cited by
- 174
- References
- 0
- FWCI
- 6.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.