The DOI matches its Crossref record; 94 of the 95 references it cites were found in a registry or an index.
Design and implementation of functional nanoelectronic interfaces with biomolecules, cells, and tissue using nanowire device arrays.
Open accessAbstract
Nanowire FETs (NWFETs) are promising building blocks for nanoscale bioelectronic interfaces with cells and tissue since they are known to exhibit exquisite sensitivity in the context of chemical and biological detection, and have the potential to form strongly coupled interfaces with cell membranes. We present a general scheme that can be used to assemble NWs with rationally designed composition and geometry on either planar inorganic or biocompatible flexible plastic surfaces. We demonstrate that these devices can be used to measure signals from neurons, cardiomyocytes, and heart tissue. Reported signals are in millivolts range, which are equal to or substantially greater than those recorded with either planar FETs or multielectrode arrays, and demonstrate one unique advantage of NW-based devices. Basic studies showing the effect of device sensitivity and cell/substrate junction quality on signal magnitude are presented. Finally, our demonstrated ability to design high-density arrays of NWFETs enables us to map signal at the subcellular level, a functionality not enabled by conventional microfabricated devices. These advances could have broad applications in high-throughput drug assays, fundamental biophysical studies of cellular function, and development of powerful prosthetics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“High-density arrays of nanowire FETs enabled mapping signals at the subcellular level – a functionality that is not possible with conventional microfabricated devices (Timko et al., 2010).”
From Human Brain/Cloud Interface (2019) · cites this paper as Timko et al., 2010
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physics of Semiconductor Devices
Sze, S. M., & Ng, K. K. (2006) · doi:10.1002/0470068329 · Cited by 14,627
Physics of Semiconductor Devices
Colinge, J.-P., & Colinge, C. (2002) · Kluwer Academic Publishers eBooks · doi:10.1007/b117561 · Cited by 14,074
Nanowire Nanosensors for Highly Sensitive and Selective Detection of Biological and Chemical Species
Cui, Y., Wei, Q., Park, H., & Lieber, C. M. (2001) · Science · doi:10.1126/science.1062711 · Cited by 5,857
Self-citationIon Channels/Excitable Membranes
(2011) · Springer eBooks · doi:10.1007/springerreference_33998 · Cited by 4,066
Chemistry and Physics in One Dimension: Synthesis and Properties of Nanowires and Nanotubes
Hu, J., Odom, T. W., & Lieber, C. M. (1999) · Accounts of Chemical Research · doi:10.1021/ar9700365 · Cited by 3,344
Self-citationFunctional Nanoscale Electronic Devices Assembled Using Silicon Nanowire Building Blocks
Cui, Y., & Lieber, C. M. (2001) · Science · doi:10.1126/science.291.5505.851 · Cited by 3,243
Self-citationTheoretical Neuroscience: Computational and Mathematical Modeling of Neural Systems
Dayan, P., & Abbott, L. F. (2001) · Cited by 3,153
Multiplexed electrical detection of cancer markers with nanowire sensor arrays
Zheng, G., Patolsky, F., Cui, Y., Wang, W. U., & Lieber, C. M. (2005) · Nature Biotechnology · doi:10.1038/nbt1138 · Cited by 2,461
Self-citationNanoelectronics from the bottom up
Lu, W. D., & Lieber, C. M. (2007) · Nature Materials · doi:10.1038/nmat2028 · Cited by 1,541
Self-citationLabel-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352
Cited by
Sorted by citations
Items 101–113 of 113
STUDY ON THE SENSITIVITY OF FUNCTIONALIZEDNANOWIRES USING VARIED CHEMICALS
Hsu, C.-C., & Lin, S. (2013) · NCHU Institutional Repository CRIS · doi:10.6287/jenchu.2013.2403.02
Zimmerman, J. F., & Tian, B. (2014) · Royal Society of Chemistry eBooks · doi:10.1039/9781782625209-00167
Self-citationElectrical interfacing of nanowire devices with cells and tissues
Paul, M., Murray, G. F., & Tian, B. (2015) · Elsevier eBooks · doi:10.1016/b978-1-78242-253-2.00019-0
Self-citationFlexible and Stretchable Biointegrated Electronics Using Silicon Nanomembranes
Kim, J., Lee, M., Shim, H. J., & Kim, D. (2016) · Wiley eBooks · doi:10.1002/9783527691005.ch6
Thermal Drawing of High-Density In-fiber Arrays of Well-Ordered 5-nm-Diameter Nanowires
Kaufman, J. J., Tao, G., Shabahang, S., & Abouraddy, A. F. (2016) · Photonics and Fiber Technology Congress (ACOFT, BGPP, NP) · doi:10.1364/acoft.2016.ath2c.2
Nam, H. (2016) · Deep Blue (University of Michigan)
Chapter 14: III–V Nanowires: Transistor and Photovoltaic Applications
(2016) · CRC Press eBooks · doi:10.1201/9781315364407-18
Transition metal dichalcogenides as ultrasensitive and high-resolution biosensing nodes
Liang, X. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-818386-1.00004-7
Electrodes for Cell Sensors Interfacing
Ben‐Yoav, H., Ragones, H., Pandey, R., Fiaschi, G., & Shacham‐Diamand, Y. (2020) · Springer eBooks · doi:10.1007/978-3-319-47405-2_125-1
Electrodes for Cell Sensors Interfacing
Ben‐Yoav, H., Ragones, H., Pandey, R., Fiaschi, G., & Shacham‐Diamand, Y. (2021) · Springer eBooks · doi:10.1007/978-3-030-23217-7_125
Álvarez, A. D. (2016) · theses.fr (ABES) · doi:10.70675/d78e3ec5z9cc8z45cfza945z1f51cde935a7
Metadata
- Authors
- Timko, B. P., Cohen-Karni, T., Qing, Q., Tian, B., & Lieber, C. M.
- Affiliations
- Harvard University (US)
- Venue
- IEEE Transactions on Nanotechnology
- Published
- 2010-05
- Volume
- 9
- Issue
- 3
- Pages
- 269-280
- ISSN
- 1536-125X (ISSN-L)
- 1941-0085
- PMC
- PMC3140208
- OpenAlex
- W2121172655
- Cited by
- 114
- References
- 95
- Citations by year
- 2025: 2 · 2024: 1 · 2022: 1 · 2021: 7 · 2020: 4 · 2019: 6 · 2018: 5 · 2017: 8 · 2016: 9 · 2015: 14 · 2014: 12 · 2013: 14 · 2012: 13
- FWCI
- 6.22
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- IEEE Transactions on Nanotechnology (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- DSpace@MIT (Massachusetts Institute of Technology) (submittedVersion, cc-by-nc)
- Figshare (submittedVersion, cc-by)
- KiltHub Repository
- Funders
- National Institutes of Health (DP1OD003900)
- Topics
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Nanowire Synthesis and Applications
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advancements in Semiconductor Devices and Circuit Design
- Keywords
- nanowire field-effect transistors, bioelectronic interfaces, flexible plastic substrates, myocardium, drug assay, prosthetics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review