Conceptual design of a proton computed tomography system for applications in proton radiation therapy
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Proton computed tomography (pCT) has the potential to improve the accuracy of dose calculations for proton treatment planning, and will also be useful for pretreatment verification of patient positioning relative to the proton beam. A design study was performed to define the optimal approach to a pCT system based on specifications for applications in proton therapy. Conceptual and detailed design of a pCT system is presented; the system consists of a silicon-based particle tracking system and a crystal calorimeter to measure energy loss of individual protons. We discuss the formation of pCT images based on the reconstruction of volume electron density maps and the suitability of analytic and statistical algorithms for image reconstruction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Agostinelli, S., Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce, P., Asai, M., Axen, D., Banerjee, S., Barrand, G., et al. (2003) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(03)01368-8 · Cited by 25,106 · cited 1×
“Simulated pCT scan data were generated by the GEANT4 MC simulation code [18].”
MethodSelf-citationMaximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Accelerated image reconstruction using ordered subsets of projection data
Hudson, H. M., & Larkin, R. S. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363108 · Cited by 3,711 · cited 1×
“With the ordered subset (OS) strategy [17], the computa-”
MethodEM reconstruction algorithms for emission and transmission tomography.
Lange, K. L., & Carson, R. E. (1984) · PubMed · Cited by 1,769
Levitan, E., & Herman, G. T. (1987) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1987.4307826 · Cited by 445
Stereotactic radiosurgery: a review and comparison of methods.
Phillips, M. H., Stelzer, K. J., Griffin, T. W., Mayberg, M. R., & Winn, H. R. (1994) · Journal of Clinical Oncology · doi:10.1200/jco.1994.12.5.1085 · Cited by 137 · cited 1×
“For example, in radiosurgery applications, where large doses of radiation are delivered to intracranial targets that are often within a few millimeters of critical normal structures at risk, dose localization accuracy requirements of the order of 1 mm are usually cited [2].”
BackgroundMueller, K., & Yagel, R. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.897815 · Cited by 129
Self-citationHart, H. E., & Liang, Z. (1987) · Bulletin of Mathematical Biology · doi:10.1007/bf02459960 · Cited by 32
Self-citationLiang, Z., & HART, H. (1987) · Bulletin of Mathematical Biology · doi:10.1007/bf02459959 · Cited by 21
Self-citationTowards a unified framework for rapid 3D computed tomography on commodity GPUs
Xu, F., & Mueller, K. D. (2004) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2003.1352457 · Cited by 13
Self-citation
Cited by
Newhauser, W. D., & Zhang, R. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/8/r155 · Cited by 675
Metadata
- Authors
- Schulte, R., Bashkirov, V., Li, T., Liang, Z., Mueller, K., Heimann, J., Johnson, L. R., Keeney, B., Sadrozinski, H. F.-W., Seiden, A., Williams, D. C., Zhang, L., Li, Z., Peggs, S., Satogata, T., & Woody, C.
- Venue
- IEEE Transactions on Nuclear Science
- Published
- 2004-06
- Volume
- 51
- Issue
- 3
- Pages
- 866-872
- ISSN
- 0018-9499 (ISSN-L)
- OpenAlex
- W2126636772
- Cited by
- 224
- References
- 10
- FWCI
- 3.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.