CoChat

Rapid 3-D cone-beam reconstruction with the simultaneous algebraic reconstruction technique (SART) using 2-D texture mapping hardware

Mueller, K., Yagel, R. · 2000 · IEEE Transactions on Medical Imaging
Cited by 129

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Algebraic reconstruction methods, such as the algebraic reconstruction technique (ART) and the related simultaneous ART (SART). reconstruct a two-dimensional (2-D) or three-dimensional (3-D) object from its X-ray projections. The algebraic methods have, in certain scenarios, many advantages over the more popular Filtered Backprojection approaches and have also recently been shown to perform well for 3-D cone-beam reconstruction. However, so far the slow speed of these iterative methods have prohibited their routine use in clinical applications. In this paper, we address this shortcoming and investigate the utility of widely available 2-D texture mapping graphics hardware for the purpose of accelerating the 3-D algebraic reconstruction. We find that this hardware allows 3-D cone-beam reconstructions to be obtained at almost interactive speeds, with speed-ups of over 50 with respect to implementations that only use general-purpose CPUs. However, we also find that the reconstruction quality is rather sensitive to the resolution of the framebuffer, and to address this critical issue we propose a scheme that extends the precision of a given framebuffer by 4 bits, using the color channels. With this extension, a 12-bit framebuffer delivers useful reconstructions for 0.5% tissue contrast, while an 8-bit framebuffer requires 4%. Since graphics hardware generates an entire image for each volume projection, it is most appropriately used with an algebraic reconstruction method that performs volume correction at that granularity as well, such as SART or SIRT. We chose SART for its faster convergence properties.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/42.897815

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 129

Metadata

Authors
Mueller, K., & Yagel, R.
Venue
IEEE Transactions on Medical Imaging
Published
2000
Volume
19
Issue
12
Pages
1227-1237
ISSN
0278-0062 (ISSN-L)
OpenAlex
W2140922423
Cited by
129
References
1
FWCI
3.06
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Rapid 3-D cone-beam reconstruction with the simultaneous algebraic reconstruction technique (SART) using 2-D texture mapping hardware. https://app.cochat.ai/papers/10.1109/42.897815
The paper
Mueller, K., & Yagel, R. (2000). Rapid 3-D cone-beam reconstruction with the simultaneous algebraic reconstruction technique (SART) using 2-D texture mapping hardware. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.897815

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.