Improving signal reliability for on-line joint angle estimation from nerve cuff recordings of muscle afferents
Abstract
Closed-loop functional electrical stimulation (FES) applications depend on sensory feedback, thus, it is important to continuously investigate new methods to obtain reliable feedback signals. The objective of the present paper was to examine the feasibility of using an artificial neural network (ANN) to predict joint angle from whole nerve cuff recordings of muscle afferent activity within a physiological range of motion. Furthermore, we estimated how small changes in joint angle that can be detected from the nerve cuff recordings. Neural networks were tested with data obtained from ten acute rabbit experiments in simulated, on-line experiments. The electroneurograms (ENG) of the tibial and peroneal nerves were recorded during passive ankle joint rotation. To decrease the joint angle prediction error with new rabbit data, we attempted to pretune the nerve signals and re-trained the ANNs with the pretuned data. With these procedures we were able to compensate for interrabbit variability. On average the mean prediction errors were less than 2.0 degrees (a total excursion of 20 degrees) and we were able to predict joint angles from muscle afferent activity with accuracy close to the best-estimated angular resolution. The angular resolution was found to depend on the initial joint angle and the actual step size taken and we found that there was a low probability of detecting joint angle changes less than 1.5 degrees. We thus suggest that muscle afferent activity is applicable as…
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Recorded ENG using cuff electrodes allowed prediction of ankle movements in an animal model.
“Recorded ENG signals using cuff electrodes allowed the prediction of ankle movements in an animal model (Micera et al., 2001a; Jensen et al., 2002; Cavallaro et al., 2003)”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Jensen et al., 2002
Cites
Sensory nerve recording for closed‐loop control to restore motor functions
Popovic, D. B., Stein, R. B., Jovanovic, K. L., Dai, R., Kostov, A., & Armstrong, W. W. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.247801 · Cited by 159 · see citing works
Micera, S., Jensen, W., Sepulveda, F., Riso, R. R., & Sinkjaer, T. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.930903 · Cited by 58 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · see citing works
- Authors
- Jensen, W., Sinkjaer, T., & Sepulveda, F.
- Affiliations
- Aalborg University (DK)
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2002-09
- Volume
- 10
- Issue
- 3
- Pages
- 133-139
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2160065833
- Cited by
- 26
- References
- 2
- Citations by year
- 2019: 2 · 2018: 1 · 2017: 1 · 2016: 1 · 2013: 1
- FWCI
- 1.78
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- VBN Forskningsportal (Aalborg Universitet) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- joint angle estimation, electroneurogram, artificial neural networks, sensory feedback, tibial nerve, peroneal nerve, angular resolution, signal reliability
- MeSH terms
- Animals, Ankle Joint, Electrodes, Implanted, Feedback, Female, Nerve Fibers, Peroneal Nerve, Quality Control, Rabbits, Rotation, Sensitivity and Specificity, Tibial Nerve, Reproducibility of Results, Neural Networks, Computer, Muscle, Skeletal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review