The DOI matches its Crossref record.
Discrimination of walking patterns using wavelet-based fractal analysis
Abstract
In this paper, we attempted to classify the acceleration signals for walking along a corridor and on stairs by using the wavelet-based fractal analysis method. In addition, the wavelet-based fractal analysis method was used to evaluate the gait of elderly subjects and patients with Parkinson's disease. The triaxial acceleration signals were measured close to the center of gravity of the body while the subject walked along a corridor and up and down stairs continuously. Signal measurements were recorded from 10 healthy young subjects and 11 elderly subjects. For comparison, two patients with Parkinson's disease participated in the level walking. The acceleration signal in each direction was decomposed to seven detailed signals at different wavelet scales by using the discrete wavelet transform. The variances of detailed signals at scales 7 to 1 were calculated. The fractal dimension of the acceleration signal was then estimated from the slope of the variance progression. The fractal dimensions were significantly different among the three types of walking for individual subjects (p < 0.01) and showed a high reproducibility. Our results suggest that the fractal dimensions are effective for classifying the walking types. Moreover, the fractal dimensions were significantly higher for the elderly subjects than for the young subjects (p < 0.01). For the patients with Parkinson's disease, the fractal dimensions tended to be higher than those of healthy subjects. These results suggest that the acceleration signals change into a more complex pattern with aging and with Parkinson's disease, and the fractal dimension can be used to evaluate the gait of elderly subjects and patients with Parkinson's disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mathie, M. J., Coster, A. C. F., Lovell, N. H., & Celler, B. G. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/2/r01 · Cited by 829
Gait Assessment in Parkinson's Disease: Toward an Ambulatory System for Long-Term Monitoring
Salarian, A., Russmann, H., Vingerhoets, F. J. G., Dehollain, C., Blanc, Y., Burkhard, P. R., & Aminian, K. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827933 · Cited by 659
Activity identification using body-mounted sensors—a review of classification techniques
Preece, S. J., Goulermas, J. Y., Kenney, L. P. J., Howard, D., Meijer, K., & Crompton, R. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/4/r01 · Cited by 600
Preprocessing techniques for context recognition from accelerometer data
Figo, D., Diniz, P. C., Ferreira, D. R., & Cardoso, J. M. P. (2010) · Personal and Ubiquitous Computing · doi:10.1007/s00779-010-0293-9 · Cited by 578
Preece, S. J., Goulermas, J. Y., Kenney, L. P. J., & Howard, D. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2006190 · Cited by 551
Metadata
- Authors
- Sekine, M., Tamura, T., Akay, M., Fujimoto, T., Togawa, T., & Fukui, Y.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2002-09
- Volume
- 10
- Issue
- 3
- Pages
- 188-196
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2134020192
- Cited by
- 201
- References
- 0
- FWCI
- 14.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Discrimination of walking patterns using wavelet-based fractal analysis. https://app.cochat.ai/papers/10.1109/tnsre.2002.802879
- The paper
- Sekine, M., Tamura, T., Akay, M., Fujimoto, T., Togawa, T., & Fukui, Y. (2002). Discrimination of walking patterns using wavelet-based fractal analysis. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2002.802879
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.