The use of EEG modifications due to motor imagery for brain-computer interfaces
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The opening of a communication channel between brain and computer [brain-computer interface (BCI)] is possible by using changes in electroencephalogram (EEG) power spectra related to the imagination of movements. In this paper, we present results obtained by recording EEG during an upper limb motor imagery task in a total of 18 subjects by using low-resolution surface Laplacian, different linear and quadratic classifiers, as well as a variable number of scalp electrodes, from 2 to 26. The results (variable correct classification rate of mental imagery between 75% and 95%) suggest that it is possible to recognize quite reliably ongoing mental movement imagery for BCI applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Motor imagery and direct brain-computer communication
Pfurtscheller, G., & Neuper, C. (2001) · Proceedings of the IEEE · doi:10.1109/5.939829 · Cited by 1,990
Brain oscillations control hand orthosis in a tetraplegic
Pfurtscheller, G., Guger, C., Müller, G., Krausz, G., & Neuper, C. (2000) · Neuroscience Letters · doi:10.1016/s0304-3940(00)01471-3 · Cited by 472 · cited 1×
“[2], also extending their results to normal subjects, whose cortical representation of the hand area, sampled from the two electrodes, is still intact and engaged in the network that allows the subject to control his muscles.”
Cited by
Bashashati, A., Fatourechi, M., Ward, R. K., & Birch, G. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r03 · Cited by 907
Combining brain-computer interfaces and assistive technologies: state-of-the-art and challenges
Millán, J. D. R. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00161 · Cited by 866
EMG and EOG artifacts in brain computer interface systems: A survey
Fatourechi, M., Bashashati, A., Ward, R. K., & Birch, G. E. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.10.019 · Cited by 638
An improved P300-based brain-computer interface
Serby, H., Yom-Tov, E., & Inbar, G. F. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.841878 · Cited by 403
A Comprehensive Survey of Brain Interface Technology Designs
Mason, S. G., Bashashati, A., Fatourechi, M., Navarro, K. F., & Birch, G. E. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9170-0 · Cited by 299
Tenke, C. E., & Kayser, J. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2012.06.005 · Cited by 273
Frantzidis, C. A., Bratsas, C., Papadelis, C. L., Konstantinidis, E., Pappas, C., & Bamidis, P. D. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2041553 · Cited by 247
“Moreover, the Mahalanobis classifier eliminates the scaling of the coordinate axis as well as and correlation effects between the used features [52].”
MethodMotor imagery and EEG-based control of spelling devices and neuroprostheses
Neuper, C., Müller-Putz, G. R., Scherer, R., & Pfurtscheller, G. (2006) · Progress in Brain Research · doi:10.1016/s0079-6123(06)59025-9 · Cited by 208
Classifying EEG-based motor imagery tasks by means of time–frequency synthesized spatial patterns
Wang, T., Deng, J., & He, B. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.06.022 · Cited by 203
“The power spectrum of EEG trials (estimated by classical Welch periodogram method) with respect to that of baseline also proved to be practical by combining low-resolution surface Laplacian and linear classifiers (Cincotti et al., 2003).”
MethodWhat Disconnection Tells about Motor Imagery: Evidence from Paraplegic Patients
Alkadhi, H., Brugger, P., Boendermaker, S. H., Crelier, G., Curt, A., Hepp-Reymond, M.-C., & Kollias, S. S. (2005) · Cerebral Cortex · doi:10.1093/cercor/bhh116 · Cited by 183
“Shoham et al., 2001; Donoghue, 2002; Cincotti et al, 2003 ).”
BackgroundTenke, C. E., & Kayser, J. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.08.007 · Cited by 176
“The field of Brain Computer Interface (BCI) technology provides convincing evidence for the utility of a targeted, regional approach to qEEG (Babiloni et al., 2001; Cincotti et al., 2003; Pfurtscheller, 2003; Pineda et al., 2003; Wolpaw and McFarland, 1994), since only stable, reliable EEG changes are suitable as a re…”
BackgroundWitte, M., Kober, S. E., Ninaus, M., Neuper, C., & Wood, G. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00478 · Cited by 167
“…and during motor imagery in an event-related manner (Pfurtscheller and Neuper, 1997; Pfurtscheller and Lopes Da Silva, 1999; McFarland et al., 2000), it has been extensively used in BCI research (Cincotti et al., 2003; Pfurtscheller et al., 2006; Mellinger et al., 2007; Blankertz et al., 2010a).”
Separable Common Spatio-Spectral Patterns for Motor Imagery BCI Systems
Aghaei, A. S., Mahanta, M. S., & Plataniotis, K. N. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2487738 · Cited by 165
“ume conduction [33], [34].”
Detecting Consciousness: A Unique Role for Neuroimaging
Owen, A. M. (2013) · Annual Review of Psychology · doi:10.1146/annurev-psych-113011-143729 · Cited by 122
“Motor imagery also produces clearly distinguishable modulation of EEG sensorimotor rhythms (Cincotti et al. 2003, Wolpaw et al. 1991) similar to those seen during motor execution, and this has been the basis of several recent attempts to detect conscious awareness after severe brain injury.”
BackgroundHigh-resolution EEG techniques for brain-computer interface applications
Cincotti, F., Mattia, D., Aloise, F., Bufalari, S., Astolfi, L., De Vico Fallani, F., Tocci, A., Bianchi, L., Marciani, M. G., Gao, S., et al. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.06.031 · Cited by 115
Self-citation
Metadata
- Authors
- Cincotti, F., Mattia, D., Babiloni, C., Carducci, F., Salinari, S., Bianchi, L., Marciani, M. G., & Babiloni, F.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2003-06
- Volume
- 11
- Issue
- 2
- Pages
- 131-133
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2111841470
- Cited by
- 64
- References
- 2
- FWCI
- 2.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.