The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Robust classification of EEG signal for brain-computer interface
Open accessAbstract
We report the implementation of a text input application (speller) based on the P300 event related potential. We obtain high accuracies by using an SVM classifier and a novel feature. These techniques enable us to maintain fast performance without sacrificing the accuracy, thus making the speller usable in an online mode. In order to further improve the usability, we perform various studies on the data with a view to minimizing the training time required. We present data collected from nine healthy subjects, along with the high accuracies (of the order of 95% or more) measured online. We show that the training time can be further reduced by a factor of two from its current value of about 20 min. High accuracy, fast learning, and online performance make this P300 speller a potential communication tool for severely disabled individuals, who have lost all other means of communication and are otherwise cut off from the world, provided their disability does not interfere with the performance of the speller.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wu, Y. (1999) · Technometrics · doi:10.1080/00401706.1999.10485951 · Cited by 27,221
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228
The mental prosthesis: assessing the speed of a P300-based brain-computer interface
Donchin, E., Spencer, K. M., & Wijesinghe, R. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847808 · Cited by 1,222
BCI Competition 2003—Data Set IIb: Support Vector Machines for the P300 Speller Paradigm
Kaper, M., Meinicke, P., Grossekathoefer, U., Lingner, T., & Ritter, H. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826698 · Cited by 496
High performance p300 speller for brain-computer interface
Guan, C., Thulasidas, M., & Wu, J. (2005) · IEEE International Workshop on Biomedical Circuits and Systems, 2004. · doi:10.1109/biocas.2004.1454155 · Cited by 165
Self-citationImproving Transfer Rates in Brain Computer Interfacing: A Case Study
Meinicke, P., Kaper, M., Hoppe, F., Heumann, M., & Ritter, H. J. (2002) · Cited by 89
EEG ocular artifact removal through ARMAX model system identification using extended least squares
Haas, S. M., Frei, M. G., Osorio, I., Pasik-Duncan, B., & Radel, J. D. (2003) · Communications in Information and Systems · doi:10.4310/cis.2003.v3.n1.a2 · Cited by 50
Generalizing to new subjects in brain-computer interfacing
Kaper, M., & Ritter, H. J. (2005) · doi:10.1109/iembs.2004.1404214 · Cited by 38
Effect of ocular artifact removal in brain computer interface accuracy
Thulasidas, M., Guan, C., Ranganatha, S., Wu, J., Zhu, X., & Xu, W. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404220 · Cited by 12
Self-citation
Research works printed but not linked: 3
- Wolpaw, Brain–Computer interfaces (BCI’s) for communication and control: Current status, 29
- Müller, Machine learning techniques for brain-computer interfaces, 11
- Thulasidas, Optimization of BCI speller based on P300 potential, 10.1109/IEMBS.2005.1615702 · doi:10.1109/iembs.2005.1615702
Cited by
A review of classification algorithms for EEG-based brain–computer interfaces
Lotte, F., Congedo, M., Lécuyer, A., Lamarche, F., & Arnaldi, B. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r01 · Cited by 2,665
Brain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
An efficient P300-based brain–computer interface for disabled subjects
Hoffmann, U., Vesin, J.-M., Ebrahimi, T., & Diserens, K. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.03.005 · Cited by 859
Toward enhanced p300 speller performance
Krusienski, D. J., Sellers, E. W., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.07.017 · Cited by 749
BCI competition III: Dataset II—Ensemble of SVMs for BCI P300 speller
Rakotomamonjy, A., & Guigue, V. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.915728 · Cited by 512
Metadata
- Authors
- Thulasidas, M., Guan, C., & Wu, J.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2006-03
- Volume
- 14
- Issue
- 1
- Pages
- 24-29
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2131153423
- Cited by
- 261
- References
- 11
- FWCI
- 8.45
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Robust classification of EEG signal for brain-computer interface. https://app.cochat.ai/papers/10.1109/tnsre.2005.862695
- The paper
- Thulasidas, M., Guan, C., & Wu, J. (2006). Robust classification of EEG signal for brain-computer interface. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2005.862695
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.