Electrocorticography-based brain computer Interface-the seattle experience
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Electrocorticography (ECoG) has been demonstrated to be an effective modality as a platform for brain-computer interfaces (BCIs). Through our experience with ten subjects, we further demonstrate evidence to support the power and flexibility of this signal for BCI usage. In a subset of four patients, closed-loop BCI experiments were attempted with the patient receiving online feedback that consisted of one-dimensional cursor movement controlled by ECoG features that had shown correlation with various real and imagined motor and speech tasks. All four achieved control, with final target accuracies between 73%-100%. We assess the methods for achieving control and the manner in which enhancing online control can be accomplished by rescreening during online tasks. Additionally, we assess the relevant issues of the current experimental paradigm in light of their clinical constraints.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 1×
“A single isolated cortical signal has been shown to be sufficient for basic tasks such as controlling a light switch [1], and even more complex tasks including moving a computer cursor [2], spelling out messages [3], or controlling an upper extremity grasping neuroprosthesis [4].”
Background
Cited by
Zander, T. O., & Kothe, C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025005 · Cited by 887
Spectral Changes in Cortical Surface Potentials during Motor Movement
Miller, K. J., Leuthardt, E. C., Schalk, G., Rao, R. P. N., Anderson, N. R., Moran, D. W., Miller, J. W., & Ojemann, J. G. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.3886-06.2007 · Cited by 738
Self-citationBrain-Computer Interfaces in Medicine
Shih, J. J., Krusienski, D. J., & Wolpaw, J. R. (2012) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2011.12.008 · Cited by 724
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Cortical activity during motor execution, motor imagery, and imagery-based online feedback
Miller, K. J., Schalk, G., Fetz, E. E., den Nijs, M., Ojemann, J. G., & Rao, R. P. N. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0913697107 · Cited by 622
Self-citationThink to Move: a Neuromagnetic Brain-Computer Interface (BCI) System for Chronic Stroke
Buch, E., Weber, C., Cohen, L. G., Braun, C., Dimyan, M. A., Ard, T., Mellinger, J., Caria, A., Soekadar, S., Fourkas, A., et al. (2008) · Stroke · doi:10.1161/strokeaha.107.505313 · Cited by 600
Enhanced performance by a hybrid NIRS–EEG brain computer interface
Fazli, S., Mehnert, J., Steinbrink, J., Curio, G., Villringer, A., Müller, K.-R., & Blankertz, B. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.07.084 · Cited by 599
Combrisson, E., & Jerbi, K. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.01.010 · Cited by 599
Clinical Applications of Brain-Computer Interfaces: Current State and Future Prospects
Mak, J. N., & Wolpaw, J. R. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2035356 · Cited by 509
Lachaux, J.-P., Axmacher, N., Mormann, F., Halgren, E., & Crone, N. E. (2012) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2012.06.008 · Cited by 506
Two-dimensional movement control using electrocorticographic signals in humans
Schalk, G., Miller, K. J., Anderson, N. R., Wilson, J. A., Smyth, M. D., Ojemann, J. G., Moran, D. W., Wolpaw, J. R., & Leuthardt, E. C. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/1/008 · Cited by 482
Self-citationBrain-Computer Interfaces Using Electrocorticographic Signals
Schalk, G., & Leuthardt, E. C. (2011) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2011.2172408 · Cited by 427
Self-citationBrain–computer interface systems: progress and prospects
Allison, B. Z., Wolpaw, E. W., & Wolpaw, J. R. (2007) · Expert Review of Medical Devices · doi:10.1586/17434440.4.4.463 · Cited by 420
Long-term asynchronous decoding of arm motion using electrocorticographic signals in monkey
Chao (2010) · Frontiers in Neuroengineering · doi:10.3389/fneng.2010.00003 · Cited by 341
Prediction of arm movement trajectories from ECoG-recordings in humans
Pistohl, T., Ball, T., Schulze-Bonhage, A., Aertsen, A., & Mehring, C. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.10.001 · Cited by 331
Summary of over Fifty Years with Brain-Computer Interfaces—A Review
Kawala-Sterniuk, A., Browarska, N., Al-Bakri, A., Pelc, M., Zygarlicki, J., Sidikova, M., Martinek, R., & Gorzelanczyk, E. J. (2021) · Brain Sciences · doi:10.3390/brainsci11010043 · Cited by 292
Decoding flexion of individual fingers using electrocorticographic signals in humans
Kubánek, J., Miller, K. J., Ojemann, J. G., Wolpaw, J. R., & Schalk, G. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/6/066001 · Cited by 285
Self-citationDecoding natural grasp types from human ECoG
Pistohl, T., Schulze-Bonhage, A., Aertsen, A., Mehring, C., & Ball, T. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.06.084 · Cited by 249
“Control strategies for these BMIs often involve neural activity related to movement execution or imagination of movements of different body parts with spatially separate representations in the motor cortex (e.g., Blankertz et al., 2007; Neuper et al., 2006).”
BackgroundInfluentialDecoding spoken words using local field potentials recorded from the cortical surface
Kellis, S., Miller, K., Thomson, K., Brown, R., House, P., & Greger, B. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/5/056007 · Cited by 235
Self-citationA Practical Guide to Brain–Computer Interfacing with BCI2000
Schalk, G., & Mellinger, J. (2010) · Springer eBooks · doi:10.1007/978-1-84996-092-2 · Cited by 216
Self-citationWIMAGINE: Wireless 64-Channel ECoG Recording Implant for Long Term Clinical Applications
Mestais, C. S., Charvet, G., Sauter-Starace, F., Foerster, M., Ratel, D., & Benabid, A. L. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2333541 · Cited by 202
Flint, R. D., Wright, Z. A., Scheid, M. R., & Slutzky, M. W. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/5/056005 · Cited by 183
Neurotechnologies for Human Cognitive Augmentation: Current State of the Art and Future Prospects
Cinel, C., Valeriani, D., & Poli, R. (2019) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2019.00013 · Cited by 178
Bai, O., Lin, P., Vorbach, S., Floeter, M. K., Hattori, N., & Hallett, M. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/1/003 · Cited by 159
Decoding Inner Speech Using Electrocorticography: Progress and Challenges Toward a Speech Prosthesis
Martin, S., Iturrate, I., Millán, J. D. R., Knight, R. T., & Pasley, B. N. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00422 · Cited by 115
Task-Specific somatosensory feedback via cortical stimulation in humans
Cronin, J. A., Wu, J., Collins, K. L., Sarma, D., Rao, R. P. N., Ojemann, J. G., & Olson, J. D. (2016) · IEEE Transactions on Haptics · doi:10.1109/toh.2016.2591952 · Cited by 68
“[18]).”
Self-citationMoly, A., Costecalde, T., Martel, F., Martin, M., Larzabal, C., Karakas, S., Verney, A., Charvet, G., Chabardes, S., Benabid, A. L., et al. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac59a0 · Cited by 65
Recording and decoding for neural prostheses
Warren, D. J., Kellis, S., Nieveen, J. G., Wendelken, S. M., Dantas, H., Davis, T. S., Hutchinson, D. T., Normann, R. A., Clark, G. A., & Mathews, V. J. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2507180 · Cited by 52
“Early studies used motor and speech imagery to control up to 2 DoFs [122], [123].”
Background
Metadata
- Authors
- Leuthardt, E. C., Miller, K. J., Schalk, G., Rao, R. P. N., & Ojemann, J. G.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2006-06
- Volume
- 14
- Issue
- 2
- Pages
- 194-198
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2128993268
- Cited by
- 245
- References
- 1
- FWCI
- 8.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.