The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
A Magneto-Inductive Sensor Based Wireless Tongue-Computer Interface
Open accessAbstract
We have developed a noninvasive, unobtrusive magnetic wireless tongue-computer interface, called "Tongue Drive," to provide people with severe disabilities with flexible and effective computer access and environment control. A small permanent magnet secured on the tongue by implantation, piercing, or tissue adhesives, is utilized as a tracer to track the tongue movements. The magnetic field variations inside and around the mouth due to the tongue movements are detected by a pair of three-axial linear magneto-inductive sensor modules mounted bilaterally on a headset near the user's cheeks. After being wirelessly transmitted to a portable computer, the sensor output signals are processed by a differential field cancellation algorithm to eliminate the external magnetic field interference, and translated into user control commands, which could then be used to access a desktop computer, maneuver a powered wheelchair, or control other devices in the user's environment. The system has been successfully tested on six able-bodied subjects for computer access by defining six individual commands to resemble mouse functions. Results show that the Tongue Drive system response time for 87% correctly completed commands is 0.8 s, which yields to an information transfer rate of approximately 130 b/min.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 2×
“For instance, gaze towards objects of interest disrupts eye-based control [10].”
Targeting Recovery: Priorities of the Spinal Cord-Injured Population
Anderson, K. D. (2004) · Journal of Neurotrauma · doi:10.1089/neu.2004.21.1371 · Cited by 2,094
An isometric tongue pointing device
Salem, C., & Zhai, S. (1997) · Proceedings of the ACM SIGCHI Conference on Human factors in computing systems · doi:10.1145/258549.259021 · Cited by 88
Research works printed but not linked: 31
- cohen, 1988, Biomedical Signal Processing, ii, 63
- fox, 1997, Applied Regression Analysis Linear Models and Related Methods, 98
- 10.1017/CBO9780511547126.003 · doi:10.1017/cbo9780511547126.003
- 10.1109/JSEN.2004.841451 · doi:10.1109/jsen.2004.841451
- 10.1109/86.808951 · DOI
- duda, 2001, Pattern Classification, 174
- 10.1136/jnnp.51.6.850 · DOI
- kandel, 2000, Principles of Neural Science
- 10.1109/21.44068 · DOI · Paper page
- 10.1109/21.478445 · DOI
- 10.1109/TNSRE.2002.806829 · DOI · Paper page
- 10.5014/ajot.47.11.1022 · doi:10.5014/ajot.47.11.1022
- 10.1109/IEMBS.2007.4353307 · DOI
- 0, TongueTouch Keypad
- 10.1088/0960-1317/8/2/028 · doi:10.1088/0960-1317/8/2/028
- huo, 2007, A wireless tongue-computer interface using stereo differential magnetic field measurement, Proc 29th IEEE Eng Med Biol Conf, 5723
- 10.1109/MEMB.2006.1705745 · DOI
- 10.1109/ICSENS.2007.4388504 · DOI
- cook, 2001, Assistive Technologies Principles and Practice
- 10.1109/TNSRE.2003.814433 · DOI · Paper page
- wang, 2008, Tracking tongue movements for environment control using particle swarm optimization, Proc IEEE Int Symp Circuits Syst, 1982
- 10.1109/TNSRE.2004.834629 · DOI
- 10.1088/1741-2560/1/2/002 · DOI
- 2008, Spinal cord injury Hope through research
- 10.1088/1741-2560/1/2/001 · DOI · Paper page
- 2008, Facts and figures at a glance
- 0, Jouse2 Compusult Limited
- 10.1109/TBME.2006.880871 · DOI · Paper page
- 0, USB Integra Mouse
- 10.1109/CNE.2007.369676 · DOI
- 10.1109/ISCAS.2006.1693892 · DOI
Cited by
Virtual reality: Applications and implications for tourism
Guttentag, D. A. (2010) · Tourism Management · doi:10.1016/j.tourman.2009.07.003 · Cited by 1,747
Ultra-thin chips for high-performance flexible electronics
Gupta, S., Navaraj, W. T., Lorenzelli, L., & Dahiya, R. (2018) · npj Flexible Electronics · doi:10.1038/s41528-018-0021-5 · Cited by 363
Johnson, A. N., Huo, X., Ghovanloo, M., & Shinohara, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-1 · Cited by 321
Self-citationMagnetoresistive Sensor Development Roadmap (Non-Recording Applications)
Zheng, C., Zhu, K., Cardoso de Freitas, S., Chang, J.-Y., Davies, J. E., Eames, P., Freitas, P. P., Kazakova, O., Kim, C., Leung, C.-W., et al. (2019) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2019.2896036 · Cited by 268
A Wireless Magnetoresistive Sensing System for an Intraoral Tongue-Computer Interface
Park, H., Kiani, M., Lee, H.-M., Kim, J., Block, J., Gosselin, B., & Ghovanloo, M. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2227962 · Cited by 79
Self-citation
Metadata
- Authors
- Huo, X., Wang, J., & Ghovanloo, M.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2008-10
- Volume
- 16
- Issue
- 5
- Pages
- 497-504
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2117323942
- Cited by
- 182
- References
- 4
- FWCI
- 26.63
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Magneto-Inductive Sensor Based Wireless Tongue-Computer Interface. https://app.cochat.ai/papers/10.1109/tnsre.2008.2003375
- The paper
- Huo, X., Wang, J., & Ghovanloo, M. (2008). A Magneto-Inductive Sensor Based Wireless Tongue-Computer Interface. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2008.2003375
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.