A Magneto-Inductive Sensor Based Wireless Tongue-Computer Interface
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
We have developed a noninvasive, unobtrusive magnetic wireless tongue-computer interface, called "Tongue Drive," to provide people with severe disabilities with flexible and effective computer access and environment control. A small permanent magnet secured on the tongue by implantation, piercing, or tissue adhesives, is utilized as a tracer to track the tongue movements. The magnetic field variations inside and around the mouth due to the tongue movements are detected by a pair of three-axial linear magneto-inductive sensor modules mounted bilaterally on a headset near the user's cheeks. After being wirelessly transmitted to a portable computer, the sensor output signals are processed by a differential field cancellation algorithm to eliminate the external magnetic field interference, and translated into user control commands, which could then be used to access a desktop computer, maneuver a powered wheelchair, or control other devices in the user's environment. The system has been successfully tested on six able-bodied subjects for computer access by defining six individual commands to resemble mouse functions. Results show that the Tongue Drive system response time for 87% correctly completed commands is 0.8 s, which yields to an information transfer rate of approximately 130 b/min.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1982) · Trends in Neurosciences · doi:10.1016/0166-2236(82)90076-5 · Cited by 9,089
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 1×
“We calculated the ITR based on Wolpaw’s definition in [ 5 ]”
Abe, S. (2001) · Springer eBooks · doi:10.1007/978-1-4471-0285-4 · Cited by 3,721
Henry, M. A. (1995) · The Journal of the American Dental Association · doi:10.14219/jada.archive.1995.0108 · Cited by 3,416
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 2×
“For instance, gaze towards objects of interest disrupts eye-based control [10].”
Pattern Classification (2nd ed.)
Duda, R. O., Hart, P. E., & Stork, D. G. (1999) · Cited by 2,520
Targeting Recovery: Priorities of the Spinal Cord-Injured Population
Anderson, K. D. (2004) · Journal of Neurotrauma · doi:10.1089/neu.2004.21.1371 · Cited by 2,094
A brain–computer interface using electrocorticographic signals in humans
Leuthardt, E. C., Schalk, G., Wolpaw, J. R., Ojemann, J. G., & Moran, D. W. (2004) · Journal of Neural Engineering · doi:10.1088/1741-2560/1/2/001 · Cited by 1,188
Applied Regression Analysis, Linear Models, and Related Methods
Gray, J. B. (1998) · Technometrics · doi:10.1080/00401706.1998.10485201 · Cited by 1,042
Assistive Technologies: Principles and Practice
Cook, A. M., & Polgar, J. M. (1995) · Cited by 1,010
Research works printed but not linked: 11
- cohen, 1988, Biomedical Signal Processing, ii, 63
- 10.1017/CBO9780511547126.003 · doi:10.1017/cbo9780511547126.003
- 10.1109/JSEN.2004.841451 · doi:10.1109/jsen.2004.841451
- 10.5014/ajot.47.11.1022 · doi:10.5014/ajot.47.11.1022
- 0, TongueTouch Keypad
- 10.1088/0960-1317/8/2/028 · doi:10.1088/0960-1317/8/2/028
- wang, 2008, Tracking tongue movements for environment control using particle swarm optimization, Proc IEEE Int Symp Circuits Syst, 1982
- 2008, Spinal cord injury Hope through research
- 2008, Facts and figures at a glance
- 0, Jouse2 Compusult Limited
- 0, USB Integra Mouse
Cited by
Virtual reality: Applications and implications for tourism
Guttentag, D. A. (2010) · Tourism Management · doi:10.1016/j.tourman.2009.07.003 · Cited by 1,747
Ultra-thin chips for high-performance flexible electronics
Gupta, S., Navaraj, W. T., Lorenzelli, L., & Dahiya, R. (2018) · npj Flexible Electronics · doi:10.1038/s41528-018-0021-5 · Cited by 363
Johnson, A. N., Huo, X., Ghovanloo, M., & Shinohara, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-1 · Cited by 321
Self-citationMagnetoresistive Sensor Development Roadmap (Non-Recording Applications)
Zheng, C., Zhu, K., Cardoso de Freitas, S., Chang, J.-Y., Davies, J. E., Eames, P., Freitas, P. P., Kazakova, O., Kim, C., Leung, C.-W., et al. (2019) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2019.2896036 · Cited by 268
A Wireless Magnetoresistive Sensing System for an Intraoral Tongue-Computer Interface
Park, H., Kiani, M., Lee, H.-M., Kim, J., Block, J., Gosselin, B., & Ghovanloo, M. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2227962 · Cited by 79
Self-citationDavanzo, N., & Avanzini, F. (2020) · IEEE Access · doi:10.1109/access.2020.3019978 · Cited by 16
“In the field of assistive technologies, several works have used tongue tip movements for the control of powered wheelchairs [69]–[71].”
Background
Metadata
- Authors
- Huo, X., Wang, J., & Ghovanloo, M.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2008-10
- Volume
- 16
- Issue
- 5
- Pages
- 497-504
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2117323942
- Cited by
- 182
- References
- 28
- FWCI
- 26.63
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.