Cited by 120Neuroscience and Neural EngineeringMuscle activation and electromyography studiesEEG and Brain-Computer Interfaces

On the Use of Longitudinal Intrafascicular Peripheral Interfaces for the Control of Cybernetic Hand Prostheses in Amputees

Micera, Silvestro, Navarro, Xavier, Carpaneto, Jacopo, Citi, Luca, Tonet, Oliver, Rossini, Paolo Maria, Carrozza, Maria Chiara, Hoffmann, Klaus Peter +3 more·2008·IEEE Transactions on Neural Systems and Rehabilitation Engineering

Abstract

Significant strides have been recently made to develop highly sensorized cybernetic prostheses aimed at restoring sensorimotor limb functions to those who have lost them because of a traumatic event (amputation). In these cases, one of the main goals is to create a bidirectional link between the artificial devices (e.g., robotic hands, arms, or legs) and the nervous system. Several human-machine interfaces (HMIs) are currently used to this aim. Among them, interfaces with the peripheral nervous system and in particular longitudinal intrafascicular electrodes can be a promising solution able to improve the current situation. In this paper, the potentials and limits of the use of this interface to control robotic devices are presented. Specific information is provided on: 1) the neurophysiological bases for the use peripheral nerve interfaces; 2) a comparison of the potentials of the different peripheral neural interfaces; 3) the possibility of extracting and appropriately interpreting the neural code for motor commands and of delivering sensory feedback by stimulating afferent fibers by using longitudinal intrafascicular electrodes; 4) a preliminary comparative analysis of the performance of this approach with the ones of others HMIs; 5) the open issues which have to be addressed for a chronic usability of this approach.

Integrity signals

Registry

Crossref · 10.1109/tnsre.2008.2006207

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • To reproduce motor and sensory functions, a nerve interface must achieve topographical and functional selectivity.

    “To adequately reproduce motor and sensory functions, it is necessary that the interface accomplish topographical selectivity and functional selectivity (Micera et al 2008).”
  • Longitudinal intra-fascicular electrodes can selectively stimulate nerve fibers, enabling activation of separate axonal subsets within a single fascicle and induction of graded responses.

    “They are also able to selectively stimulate nerve fibers, even enabling the activation of separate axonal subsets within a single fascicle [88], and the induction of graded responses [89].”
  • The first step toward a suitable reproduction of sensorimotor functionality is to determine the topographical location in the nerve for desired functions.

    “Micera et al. (2008) suggested that the first step toward a suitable reproduction of sensorimotor functionality is to determine the topographical location in the nerve for desired functions.”

    From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Micera et al., 2008

  • An ideal closed-loop bidirectional prosthesis-user interface has mandatory components: peripheral-nerve data-recording electrodes; decoding of user intention; production of motor commands for the prosthesis system; passage of this information to the controller for controlling speed/force; sensors embedded in the bionic hand/arm; and a sensory subsystem to encode feedback to an amputee through a神经?

    “According to several studies (Micera et al., 2008; Rossini et al., 2010; Raspopovic et al., 2014), an ideal closed-loop bidirectional prosthesis-user interface has the following mandatory components (see Figure 1 below): (i) peripheral-nerve data-recording electrodes; (ii) decoding of user intention; (iii) production of motor commands for the prosthesis system; (iv) passage of this information to”

    From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Micera et al., 2008

  • LIFE implants are effective for long-term recording and stimulation applications, having for example been used in humans for the recording of volitional limb movement and to elicit skin sensation of touch/pressure.

    “LIFE implants are effective for long-term recording and stimulation applications, having for example been used in humans for the recording of volitional limb movement and to elicit skin sensation of touch/pressure (Dhillon et al., 2004, 2005; Micera et al., 2008).”

The citation lists haven’t been fetched yet

References 148 · Cited by 120

Authors
Micera, S., Navarro, X., Carpaneto, J., Citi, L., Tonet, O., Rossini, P. M., Carrozza, M. C., Hoffmann, K. P., Vivo, M., Yoshida, K., & Dario, P.
Affiliations
  • Scuola Superiore Sant'Anna (IT)
  • Universitat Autònoma de Barcelona (ES)
  • IMT School for Advanced Studies Lucca (IT)
  • Università Campus Bio-Medico (IT)
  • Fraunhofer Institute for Biomedical Engineering (DE)
  • Aalborg University (DK)
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2008-10
Volume
16
Issue
5
Pages
453-472
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2138970539
Cited by
120
References
148
Citations by year
2026: 1 · 2025: 1 · 2024: 2 · 2023: 6 · 2022: 8 · 2021: 6 · 2020: 8 · 2019: 3 · 2018: 9 · 2017: 8 · 2016: 5 · 2015: 7 · 2014: 3 · 2013: 9 · 2012: 8
FWCI
1.00
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
  • PubMed (publishedVersion)
  • BOA (University of Milano-Bicocca) (submittedVersion)
  • Publikationsdatenbank der Fraunhofer-Gesellschaft (Fraunhofer-Gesellschaft) (submittedVersion)
  • Fraunhofer-Publica (Fraunhofer-Gesellschaft) (submittedVersion)
  • VBN Forskningsportal (Aalborg Universitet) (submittedVersion)
  • Open Access at Essex (University of Essex) (submittedVersion)
  • CINECA IRIS Institutional Research Information System (Sant'Anna School of Advanced Studies) (submittedVersion)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
Keywords
peripheral nerve interfaces, amputees, robotic hand control, sensory feedback, afferent stimulation
MeSH terms
Amputees, Cybernetics, Electromyography, Equipment Design, Hand, Humans, Peripheral Nerves, Robotics, Equipment Failure Analysis, Prostheses and Implants

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review