Comparative analysis of transverse intrafascicular multichannel, longitudinal intrafascicular and multipolar cuff electrodes for the selective stimulation of nerve fascicles
Open accessAbstract
This comparative study evaluates TIME, LIFE, and cuff electrodes for selective stimulation in the rat sciatic nerve.
Verified 2026-10-05 · 6 references not checked yet
AI snapshot
Written from the paper’s full text.
TL;DR
In acute rat sciatic nerve experiments, a transversely inserted multichannel intrafascicular electrode (TIME) selectively activated three hindlimb muscles through different active sites, whereas multipolar cuff electrodes selectively activated only two and longitudinal intrafascicular electrodes (LIFE) generally only one. TIME also required lower stimulation currents than cuff electrodes and achieved higher device-level selectivity.
Key findings
- TIME selectively activated plantar, gastrocnemius, and tibialis anterior muscles via separate active sites; multipolar cuff stimulation selectively activated only gastrocnemius and tibialis anterior, and LIFE did not selectively activate more than one muscle in the implanted tibial fascicle in four of five cases.
- Initial muscle activation occurred at 20–100 µA with TIME and LIFE, while cuff thresholds were three to six times higher; for plantar, the mean 5% threshold was 58 ± 7 µA with TIME versus 336 ± 32 µA with cuff.
- At activation levels above 30% of maximal CMAP, TIME reached selectivity indices above 0.6 for all three muscles (plantar 0.619 ± 0.070, gastrocnemius 0.657 ± 0.064, tibialis anterior 0.760 ± 0.050), while LIFE had no tibialis anterior activation and cuff had low plantar selectivity (0.330 ± 0.007).
- Repositioning a TIME by about 0.1 mm improved the selectivity index for plantar from 0.501 to 1 and for gastrocnemius from 0.538 to 1, with tibialis anterior changing from 0.908 to 0.975.
Methods
- Acute experiments in adult Sprague-Dawley rats implanted the rat sciatic nerve with TIME (n = 8 across tibial and peroneal fascicles; n = 3 tibial-only TIME-B), LIFE (n = 5 tibial implants, plus one peroneal implant), or a 12-pole multipolar cuff (n = 5).
- Stimulation used monophasic rectangular pulses at 0.5 Hz, 10 µs width, and 20–300 µA for TIME/LIFE or 20–800 µA for cuff; compound muscle action potentials were recorded from plantar, gastrocnemius medialis, and tibialis anterior muscles and normalized to maximal responses.
- Selectivity was quantified per active site and per device using a selectivity index, with comparisons by ANOVA and post hoc Bonferroni tests.
Limitations
- The authors state that only acute implants were tested and that chronic experiments are needed because thresholds and selectivity may change with time and accommodation inside the nerve.
- The authors note that the rat sciatic nerve is small and that applying TIME to larger nerves or humans would require a longer intraneural segment and more active contacts.
- Evident from the text: group sizes were small (n = 3–8 per condition), and the cuff electrode was implanted without aligning its tripolar sites to specific nerve fascicles.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
3 of 41 cited sources checked · 2 supported · 0 flagged · accuracy not yet measured
- Findingcitation§ 4.2. Selectivity of stimulation · p. 12
The CMAP amplitudes elicited by the TIME corresponding to the maximum SI were of a functional magnitude.
“The CMAP amplitudes elicited by the TIME corresponding to the maximum SI were of a functional magnitude (Paternostro-Sluga et al 2008).”
Quote in the paperSubstantial claim1 of 1 sources checked- cites Paternostro-Sluga et al 2008 source
The available study text describes manual muscle-strength testing and grip-force measurements in patients with radial palsy; it does not address CMAP amplitudes elicited at the TIME corresponding to maximum SI. Searches for the quoted phrase and for compound muscle action potentials and stimulation intensity found no relevant passage. The indexed passages provide no section or page number for this point. (LLM, conf=0.72)
Experimental — accuracy not yet measured
- Findingown data§ Abstract · p. 2
A single TIME device selectively activated all three tested muscles (PL, GM and TA) when different active sites were used, at both the interfascicular and intrafascicular levels.
“TIME allowed us to selectively activate the three tested muscles when stimulating through different active sites of one device, both at inter- and intrafascicular levels”
- Also stated in: § 3. Results · p. 6 · plain
“The TIME device allowed us to selectively activate the PL, GM and TA muscles when stimulating through different active sites.”
Quote in the paperSubstantial claim - Also stated in: § 3. Results · p. 6 · plain
- Findingown data§ 3. Results · p. 6
The TA muscle was not activated by tf-LIFEs implanted in the tibial nerve.
“The TA muscle was not activated by tf-LIFEs inserted in the tibial nerve”
Quote in the paperSubstantial claim - Findingown data§ Abstract · p. 2
The LIFE electrode did not selectively activate more than one muscle within the nerve fascicle in which it was implanted.
“LIFE did not activate selectively more than one muscle in the implanted nerve fascicle.”
- Also stated in: § 3. Results · p. 6 · plain
“with the tf-LIFE it was not possible to activate selectively more than one muscle (either PL or GM for the implants in the tibial nerve) in four cases out of five.”
Quote in the paperSubstantial claim - Also stated in: § 3. Results · p. 6 · plain
- Findingown data§ 3.2. Selectivity of stimulation · p. 7
The device selectivity index (SId) was significantly higher for TIMEs than for LIFEs and cuff electrodes.
“The results for the SId show that TIMEs had a SId significantly higher than LIFEs and cuff electrodes (figure 5(A)).”
Quote in the paperSubstantial claim
- Findingown data§ 3.1. Thresholds for stimulation · p. 7
The minimum stimulation thresholds of the cuff electrode for the PL muscle were significantly higher than those for the GM and TA muscles.
“Cuff minimum thresholds for the PL muscle were significantly higher ( p < 0.05) than the corresponding values for GM and TA muscles.”
Quote in the paperNot a substantial claim - Findingown data§ Abstract · p. 2
The minimum current needed to activate a muscle was significantly lower for the TIME and LIFE electrodes than for the multipolar cuff electrode.
“the minimum threshold for muscle activation with TIME and LIFE was significantly lower than with cuff electrodes”
- Also stated in: § 3.1. Thresholds for stimulation · p. 7 · plain
“The threshold for muscle activation was observed with pulses of 10 μ s duration with intensities between 20 and 100 μ A when using TIME and LIFE devices, and three to six times higher (depending on the muscle) with cuff electrodes.”
- Also stated in: § 3.2. Selectivity of stimulation · p. 7 · plain
“From the recruitment curves, it is also clear that the intensity of stimulation was quite a bit higher using cuffs rather than TIME and LIFE.”
Quote in the paperSubstantial claim - Also stated in: § 3.1. Thresholds for stimulation · p. 7 · plain
- Findingown data§ 3. Results · p. 6
In the three rats with a TIME implanted across only the tibial nerve (group B), the threshold for TA stimulation through active sites that lay outside the peroneal nerve but touched the perineurium was above 200 μA.
“In the three animals with the TIME implant made across only the tibial nerve (group B), the threshold for the stimulation of the TA for active sites that were outside the peroneal nerve but in contact with the perineurium was above 200 μ A.”
Quote in the paperSubstantial claim - Findingown data§ 3.1. Thresholds for stimulation · p. 7
The mean stimulation thresholds obtained with TIME did not differ significantly among the three muscles.
“The mean thresholds with the TIME did not differ significantly between the three muscles.”
Quote in the paperNot a substantial claim - Findingown data§ 4.2. Selectivity of stimulation · p. 12
LIFE devices obtained selective acceptable CMAP amplitude only in the GM muscle.
“LIFE devices obtained selective acceptable CMAP amplitude only in the GM muscle.”
Quote in the paperSubstantial claim - Findingreasoning§ 4.2. Selectivity of stimulation · p. 12
The obtained SI values were largest at the lower current levels when only the axonal subfascicle closest to the electrode contact was activated.
“The obtained SI values were largest at the lower current levels when only the axonal subfascicle closest to the electrode contact was activated.”
Quote in the paperSubstantial claim - Findingnone given§ 4.2. Selectivity of stimulation · p. 12
CMAPs elicited by cuff electrodes showed acceptable values only for the GM and TA muscles.
“CMAPs elicited by cuff electrodes showed acceptable values only for the GM and TA muscles.”
Quote in the paperSubstantial claim - Findingnone given§ 4. Discussion · p. 9
The intensity of stimulation needed for muscle activation was significantly lower with intraneural (TIME and LIFE) electrodes than with extraneural electrodes.
“Another important result is that, as expected, the intensity of stimulation needed for muscle activation was significantly lower with intraneural (TIME and LIFE) electrodes than with extraneural electrodes.”
Quote in the paperSubstantial claim - Findingreasoning§ 4.2. Selectivity of stimulation · p. 12
At increasing stimulus intensity levels, current spread affecting neighboring fascicles and other muscles were activated, leading to a decreased SI.
“At increasing stimulus intensity levels, current spread affecting neighboring fascicles and other muscles were activated, leading to a decreased SI.”
Quote in the paperSubstantial claim - Findingreasoning§ 4.1. Stimulation threshold for activation · p. 11
LIFEs and TIMEs implanted only in the tibial nerve branch were not able to activate the TA muscle until quite high stimulus intensities, comparable to those obtained with cuff electrodes.
“On the other hand, LIFEs and TIMEs implanted only in the tibial nerve branch were not able to activate the TA muscle, innervated by the peroneal nerve branch, until quite high stimulus intensities, comparable to those obtained with cuff electrodes”
Quote in the paperSubstantial claim - Findingown data§ 4. Discussion · p. 9
Multipolar cuff electrodes allowed for selective activation of muscles innervated by different fascicles (GM and TA muscles).
“By contrast, multipolar cuff electrodes allowed for selective activation of muscles innervated by different fascicles (GM an TA muscles)”
Quote in the paperSubstantial claim - Findingreasoning§ 4.1. Stimulation threshold for activation · p. 11
Thresholds of stimulation with cuff electrodes were three to six times higher than thresholds with TIME and LIFE for the muscles tested.
“Therefore, thresholds of stimulation with the cuff electrodes were three to six times higher than thresholds with TIME and LIFE for the muscles tested (table 2).”
Quote in the paperSubstantial claim - Findingreasoning§ 4.2. Selectivity of stimulation · p. 12
The maximal SIas obtained when stimulating through a TIME was similarly high for the three muscles tested.
“The maximal SIas obtained when stimulating through a TIME was similarly high for the three muscles tested”
Quote in the paperSubstantial claim - Findingown data§ 4.2. Selectivity of stimulation · p. 13
The TIME was the only electrode tested that provided good stimulation selectivity at interfascicular and also at intrafascicular level with one electrode implanted, even in a small nerve such as the rat sciatic nerve.
“In summary, the TIME was the only electrode tested that provided good stimulation selectivity at interfascicular and also at intrafascicular level with one electrode implanted, even in a small nerve such as the rat sciatic nerve.”
Quote in the paperSubstantial claim - Interpretationcitation§ Abstract · p. 2
Extraneural cuff electrodes predominantly excite nerve fascicles that lie superficially in the nerve.
“extraneural electrodes (cuffs) predominantly excite nerve fascicles located superficially”
- Also stated in: § 1. Introduction · p. 3 · plain
“The stimulation with cuff electrodes predominantly induces activation of large myelinated fibers and of those located at superficial locations in the nerve.”
Quote in the paperSubstantial claim0 of 2 sources checked- Rests on an assumption: The rat sciatic nerve is a valid model for evaluating the selective stimulation properties of nerve electrodes intended for neuroprosthetic applications.
- Also stated in: § 1. Introduction · p. 3 · plain
- Premisereasoning§ 1. Introduction · p. 3
Cuff electrodes have reduced selectivity because they are placed around the nerve.
“However, because they are placed around the nerve, cuff electrodes have a reduced selectivity.”
Quote in the paperSubstantial claim - Premisecitation§ 4.2. Selectivity of stimulation · p. 12
Intrafascicular stimulation achieved with electrodes such as the microelectrode array and the TIME provides highly selective access to several muscles innervated by the same nerve fascicle.
“Intrafascicular stimulation achieved with electrodes, such as the microelectrode array (MEA, Branner et al 2001) and the TIME, provides highly selective access to several muscles innervated by the same nerve fascicle.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Branner et al 2001 source
- Premisecitation§ 4.1. Stimulation threshold for activation · p. 11
Short stimulus pulses minimize the threshold charge.
“Short stimulus pulses also minimize the threshold charge (Crago et al 1974).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Crago et al 1974 source
- Premisereasoning§ 1. Introduction · p. 3
Intrafascicular electrodes are more invasive than extraneural electrodes because they lie within a fascicle in direct contact with the targeted fibers.
“Intrafascicular electrodes are placed within a fascicle in the nerve and have a direct contact to the targeted fibers and are, then, more invasive than extraneural electrodes.”
Quote in the paperSubstantial claim - Premisecitation§ 1. Introduction · p. 3
To reproduce motor and sensory functions, a nerve interface must achieve topographical and functional selectivity.
“To adequately reproduce motor and sensory functions, it is necessary that the interface accomplish topographical selectivity and functional selectivity (Micera et al 2008).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Micera et al 2008 source
- Interpretationreasoning§ 4.2. Selectivity of stimulation · p. 12
The lack of selectivity for the PL muscle obtained with cuff and LIFE devices is attributable to the transversal disposition of the contacts in TIME versus the longitudinal disposition in LIFE and the circular distribution of the extraneural contacts in cuff electrodes.
“This fact, together with the lack of selectivity for the PL muscle obtained with cuff and LIFE devices, is attributable to the transversal disposition of the contacts in TIME versus the longitudinal disposition in LIFE and the circular distribution of the extraneural contacts in cuff electrodes.”
Quote in the paperSubstantial claim - Interpretationreasoning§ 4.2. Selectivity of stimulation · p. 13
A single selective multicontact nerve electrode positioned proximally may reduce invasiveness by requiring only a single implant for multiple functions.
“A single selective multicontact nerve electrode positioned proximally may reduce invasiveness by requiring only a single implant for multiple functions.”
Quote in the paperSubstantial claim - Premisecitation§ 4.1. Stimulation threshold for activation · p. 11
Short pulse width allows better threshold separation between large and small nerve fibers.
“and better threshold separation between large and small nerve fibers (Gorman and Mortimer 1986).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Gorman and Mortimer 1986
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Study design and conductcitation§ 4.1. Stimulation threshold for activation · p. 11
The currents applied to TIME, LIFE and cuff devices remained within the range of safety.
“The currents applied to TIME, LIFE and cuff devices remained within the range of safety (Yoshida et al 2000, Navarro et al 2001, Boretius et al 2010).”
Quote in the paperNot a substantial claim0 of 3 sources checked - Premisecitation§ 4.1. Stimulation threshold for activation · p. 11
Short pulse width allows activation of more fibers in a localized region of the nerve trunk before spillover.
“The width of the applied stimuli was set to 10 μ s since short pulse width allows activation of more fibers in a localized region of the nerve trunk before spillover (Grill and Mortimer 1996a)”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Grill and Mortimer 1996a
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Interpretationown data§ 4.2. Selectivity of stimulation · p. 12
The optimal application of the TIME device may be in the portions of the peripheral nerve where different bundles of axons innervating different organs are in the inner part of the nerve forming or not a fascicle encircled by perineurium.
“These results suggest that the optimal application of the TIME device may be in the portions of the peripheral nerve where different bundles of axons innervating different organs are in the inner part of the nerve forming or not a fascicle encircled by perineurium.”
Quote in the paperSubstantial claim - Premisecitation§ 1. Introduction · p. 3
There is a trade-off between the selectivity and the invasiveness of peripheral nerve electrodes.
“There is a tradeoff between selectivity, the ability to address single nerve fibers, and invasiveness.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Micera and Navarro 2009 source
- Premisecitation§ 1. Introduction · p. 3
Initial acute animal studies showed that the TIME can provide fascicular selective stimulation.
“Initial acute animal studies have shown that TIME can provide fascicular selective stimulation (Boretius et al 2010)”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Boretius et al 2010 source
- Premisecitation§ 1. Introduction · p. 3
The muscular fascicles of the rat sciatic nerve have a known topographical distribution, with TA fibers in the peroneal branch and GM and PL fibers in distinct locations of the tibial branch.
“The fibers innervating the TA muscle are located in the peroneal branch, whereas those innervating the GM and the PL muscles are in distinct locations in the tibial branch.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Badia et al 2010 source
- Premisecitation§ 2.3. Neural stimulatot and nerve stimulation protocol · p. 5
The PL, GM and TA muscles are innervated by different fascicles or subfascicles of the rat sciatic nerve.
“Electromyographic (EMG) signals were simultaneously recorded from the PL, GM and TA muscles, which are innervated by different fascicles or subfascicles of the sciatic nerve (Badia et al 2010).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Badia et al 2010 source
- Premisecitation§ 2.3. Neural stimulatot and nerve stimulation protocol · p. 5
A short pulse width (10 μs) maximizes the differences in threshold between nerve fibers of different diameters.
“The short pulse width was chosen to maximize the threshold differences between nerve fibers of different diameters (Gorman and Mortimer 1986).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Gorman and Mortimer 1986
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation§ 4.2. Selectivity of stimulation · p. 12
Cuff electrodes with multiple contacts can produce selective activation of different muscles innervated by a peripheral nerve at the interfascicular level.
“Cuff electrodes with multiple contacts can produce selective activation of different muscles innervated by a peripheral nerve (Veraart et al 1993, Grill and Mortimer 1996b, Navarro et al 2001, Tarler and Mortimer 2004, Polasek et al 2007, Schiefer et al 2010) at the interfascicular level”
Quote in the paperSubstantial claim0 of 3 sources checked- cites Veraart et al 1993 source
- cites Grill and Mortimer 1996b
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites Navarro et al 2001
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Interpretationown data§ 4.2. Selectivity of stimulation · p. 12
Different active sites in the same TIME device could stimulate distinct groups of nerve fibers.
“indicating that different active sites in the same device could stimulate distinct groups of nerve fibers.”
Quote in the paperSubstantial claim - Interpretationown data§ 3.4. Selectivity changes by repositioning the TIME · p. 8
Once implanted, the intraneural TIME can be carefully repositioned to obtain optimal stimulation selectivity of different fascicles and subfascicles in the nerve.
“This observation is a proof of concept that, once implanted, the intraneural TIME can be carefully repositioned to obtain the optimal stimulation selectivity of different fascicles and subfascicles in the nerve.”
Quote in the paperSubstantial claim - Interpretationown data§ 4.2. Selectivity of stimulation · p. 12
The transversally inserted electrodes can provide both interfascicular and intrafascicular selective stimulation of motor fibers.
“showing the capability of the transversally inserted electrodes to provide both interfascicular and intrafascicular selective stimulation of motor fibers.”
Quote in the paperSubstantial claim - Premisenone given§ 4.2. Selectivity of stimulation · p. 12
All previously proposed indices of selectivity refer to the selectivity of one active site over one muscle, without taking into consideration all the contacts in the device or the total number of muscles aimed to be selectively activated.
“All of them refer to the selectivity of one active site over one muscle, without taking into consideration all the contacts in the device or the total number of muscles aimed to be selectively activated.”
Quote in the paperSubstantial claim
- Classified as probably not a substantial claim. 22
- May combine two claims. 22
Probably not a substantial claim: may not pass S1 (asserted), S3 (load-bearing). May combine two claims.
Premisecitation§ 4.2. Selectivity of stimulation · p. 12Bipolar transverse stimulation in a plane perpendicular to the axis of the nerve trunk increases the selectivity of the cuff between fascicles and allows improved fine tuning of nerve recruitment with respect to longitudinal tripolar stimulation.
“theoretical considerations have suggested that bipolar transverse stimulation in a plane perpendicular to the axis of the nerve trunk increases the selectivity of the cuff between fascicles and allows improved fine tuning of nerve recruitment with respect to the longitudinal tripolar stimulation used in our study (Deurloo et al 2003).”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites Deurloo et al 2003 source
Probably not a substantial claim: may not pass S3 (load-bearing).
Premisecitation§ 4.2. Selectivity of stimulation · p. 12Several indices of selectivity have been proposed as a measure of the potential functionality that nerve interfaces can offer.
“Several indices of selectivity have been proposed as a measure of the potential functionality that nerve interfaces can offer (Veraart et al 1993, Branner et al 2001, Schiefer et al 2008, Dowden et al 2009).”
Quote in the paperNot a substantial claim1 of 3 sources checkedMay combine two claims.
Findingown data§ 3. Results · p. 6When a tf-LIFE was implanted in the peroneal nerve, stimulation activated only the TA muscle and not the PL or GM muscles.
“contrarily in the case of implantation within the peroneal nerve, stimulation through the tf-LIFE only activated the TA muscle, but not the PL and GM muscles.”
Quote in the paperSubstantial claimMay combine two claims.
Findingown data§ 3.1. Thresholds for stimulation · p. 7The minimum stimulation thresholds of the tf-LIFE for the PL muscle were higher than for the GM muscle, but not significantly so.
“tf-LIFE minimum threshold values for the PL muscle were higher than for GM muscle although not significantly.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown data§ Abstract · p. 2The multipolar cuff electrode selectively activated only two of the three muscles (GM and TA), and only at the interfascicular level.
“selective activation using multipolar cuff (with a longitudinal tripolar stimulation configuration) was only possible for two muscles, at the interfascicular level”
- Also stated in: § 3. Results · p. 6 · plain
“Selective activation using a multipolar cuff electrode was only possible for two muscles, GM and TA”
Quote in the paperSubstantial claim- Also stated in: § 3. Results · p. 6 · plain
May combine two claims.
Findingown data§ 4.2. Selectivity of stimulation · p. 12No implant of LIFE or TIME restricted to the tibial nerve could activate the TA muscle in the safe range of current injected, but stimulation of the TA was possible with all the TIME implants in the full sciatic nerve.
“No implant of LIFE or TIME restricted to the tibial nerve could activate in the safe range of current injected the TA muscle innervated by the peroneal nerve branch, but stimulation of the TA was possible with all the TIME implants in the full sciatic nerve”
Quote in the paperSubstantial claimMay combine two claims.
Findingnone given§ 4. Discussion · p. 9The LIFE elicited stimulation only in the implanted nerve fascicle, and only in one animal could stimulate selectively the GM and PL muscles.
“whereas the LIFE elicited stimulation only in the implanted nerve fascicle, and only in one animal could stimulate selectively the GM and PL muscles.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Findingnone given§ 4.1. Stimulation threshold for activation · p. 11Large currents of stimulation eliciting 95% of the maximum CMAP amplitude are high enough to spread all over the nerve and thus selectivity of stimulation is lost.
“Large currents of stimulation eliciting 95% of the maximum CMAP amplitude are high enough to spread all over the nerve and, thus, selectivity of stimulation is lost.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Findingcitation§ 4.2. Selectivity of stimulation · p. 12Muscle recruitment curves as function of current amplitude were typical for the stimulation strategies used.
“Muscle recruitment curves as function of current amplitude were typical for the stimulation strategies used (Grill and Mortimer 1996b, Yoshida et al 2000, Navarro et al 2001, 2007, Polasek et al 2007).”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites Grill and Mortimer 1996b
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites Yoshida et al 2000 source
- cites Navarro et al 2001, 2007
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
Findingown data§ 3.2. Selectivity of stimulation · p. 7With the implanted LIFE, selectivity was good for the GM muscle, moderate for the PL muscle, and absent for the TA muscle.
“With the implanted LIFE good selectivity was obtained for the GM, moderate for the PL, but no activation (except from some artefactual responses due to cross-talk in the recording at high levels of stimulation; see figure 4(B)) of the TA muscle.”
Quote in the paperSubstantial claimMay combine two claims.
Findingown data§ 3. Results · p. 6As stimulus intensity increased, the CMAP amplitude grew to its maximum and the stimulus spread to surrounding fascicles, activating two of the three tested muscles.
“By progressively increasing the intensity of the stimulus, the amplitude of the CMAP increased to reach the maximal value (i.e. activation of the whole muscle); however, the stimulus spread to other surrounding fascicles, therefore activating two of the three muscles tested.”
Quote in the paperSubstantial claimMay combine two claims.
Findingreasoning§ 4.1. Stimulation threshold for activation · p. 11With the TIME there were no differences between the thresholds for the three muscles tested, while with cuff and LIFE devices thresholds for the PL muscle were always higher than for the GM muscle.
“With the TIME there were no differences between the thresholds for the three muscles tested, while with cuff and LIFE devices thresholds for the PL muscle were always higher than for the GM muscle.”
Quote in the paperSubstantial claimMay combine two claims.
Findingown data§ 4. Discussion · p. 9The TIME was effective to induce selectivity at interfascicular and intrafascicular levels, as demonstrated by selective activation of the three muscles tested with different active sites in one transversally inserted electrode.
“The results of this study show that the TIME was effective to induce selectivity at interfascicular and intrafascicular levels, as demonstrated by the selective activation of the three muscles tested (TA, GM and PL muscles) with different active sites in one transversally inserted electrode.”
Quote in the paperSubstantial claimMay combine two claims.
Findingnone given§ 4.2. Selectivity of stimulation · p. 13The LIFE allows only selectivity at the intrafascicular level, and the multipolar cuff electrode only interfascicular selectivity.
“In contrast, the LIFE allows only selectivity at the intrafascicular level, and the multipolar cuff electrode only interfascicular selectivity.”
Quote in the paperSubstantial claimMay combine two claims.
Premisecitation§ 4. Discussion · p. 11Both types of intraneural electrodes, the LIFE and the TIME, are biocompatible and do not induce significant nerve damage after implantation, similar to the cuff electrodes.
“The results indicated that both types of intraneural electrodes, the LIFE (Lago et al 2007) and the TIME (Badia et al 2011) are biocompatible and do not induce significant nerve damage after implantation, similar to the cuff electrodes (Rodr´ ıguez et al 2000).”
Quote in the paperSubstantial claim0 of 3 sources checkedClassified as probably not a substantial claim.
Interpretationreasoning§ 4.2. Selectivity of stimulation · p. 13For implants in larger nerves of bigger animals or humans, the intraneural segment of the TIME can be designed longer and with more active contacts, therefore increasing the number of nerve fascicles that may be selectively interfaced.
“For implants in larger nerves of bigger animals or humans, the intraneural segment of the TIME can be designed longer and with more active contacts, therefore increasing the number of nerve fascicles that may be selectively interfaced with respect to the rat model used in this study.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductnone given§ 2.2. Surgical procedures · p. 5The cuff was implanted without special attention to aligning the tripolar sites with distinct nerve fascicles.
“The cuff was implanted without paying special attention to the alignment of the tripolar sites with distinct nerve fascicles.”
Quote in the paperNot a substantial claimClassified as probably not a substantial claim.
Study design and conductnone given§ 2.3. Neural stimulatot and nerve stimulation protocol · p. 5The same experimental protocol was repeated for all rats and electrodes.
“The same experimental protocol was repeated for all the rats and electrodes.”
Quote in the paperSubstantial claimMay combine two claims.
Premisecitation§ 4.2. Selectivity of stimulation · p. 12The amplitude of the CMAPs correlates with the force produced and with the joint torque.
“The amplitude of the CMAPs correlates with the force produced and with the joint torque, as shown in previous studies (Navarro et al 2001, Singh et al 2000, Stieglitz et al 2003).”
Quote in the paperNot a substantial claim0 of 3 sources checkedProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Study design and conductnone given§ 2.2. Surgical procedures · p. 4Electrode insertion was monitored under a dissection microscope to ensure correct placement and adequate location of electrode sites in the nerve.
“The insertion was monitored under a dissection microscope to ensure correct placement and that the electrode sites were located adequately in the nerve.”
Quote in the paperNot a substantial claimClassified as probably not a substantial claim.
Premisecitation§ 4. Discussion · p. 9Selectivity is a key aspect for enhanced applications of neural electrodes in neuroprosthetic devices intended to provide FES.
“The issue of selectivity is one of the key aspects for enhanced applications of neural electrodes in neuroprosthetic devices intended to provide functional electrical stimulation (FES) as a means for restoring or improving neural functions which have been lost due to injuries or degeneration of the nervous system (Stein et al 1992).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Stein et al 1992
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Probably not a substantial claim: may not pass S3 (load-bearing).
Premisecitation§ 4.2. Selectivity of stimulation · p. 12Introduction of a subthreshold steering current may restrict the region of excitation of the nerve trunk, thus improving the selectivity of stimulation.
“Introduction of a subthreshold steering current may restrict the region of excitation of the nerve trunk, thus improving the selectivity of stimulation (Gorman and Mortimer 1986, Grill and Mortimer 1996a, Navarro et al 2001).”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites Gorman and Mortimer 1986
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites Grill and Mortimer 1996a
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites Navarro et al 2001
Probably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductnone given§ 2.2. Surgical procedures · p. 4The experimental protocols were approved by the Ethical Committee of the Universitat Autònoma de Barcelona.
“All procedures were performed with the rats under pentobarbital anesthesia (40 mg kg -1 i.p.) and following protocols approved by the Ethical Committee of the Universitat Aut` onoma de Barcelona.”
Quote in the paperNot a substantial claimMay combine two claims.
Interpretationreasoning§ 4.2. Selectivity of stimulation · p. 13The TIME may be appropriate for FES applications at mid and proximal levels of the nerves, reducing the number of electrodes to be surgically implanted and thus minimizing the risk of damage and the complexity of the interface connections.
“The findings of this study suggest that the TIME may be appropriate for FES applications at mid and proximal levels of the nerves, reducing the number of electrodes to be surgically implanted and thus minimizing the risk of damage and the complexity of the interface connections.”
Quote in the paperSubstantial claimMay combine two claims.
Interpretationown data§ 3. Results · p. 6At low stimulation intensity, activation of a single muscle was detected, which is attributable to close contact between one electrode site and that muscle's nerve fascicle.
“At low intensity stimulation the activation of one muscle was detected by the recording of CMAPs of low amplitude; selective stimulation of one muscle could be detected, due to the close contact of one electrode site with the corresponding muscular nerve fascicle.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Premisecitation§ 4.1. Stimulation threshold for activation · p. 11Minimizing the injected charge is important for prevention of electrode corrosion and may prevent stimulus-induced neural damage.
“Minimizing the injected charge is an important consideration for prevention of electrode corrosion (Robblee and Rose 1990), which depends on the charge density on the electrode surface, and may prevent stimulus-induced neural damage (Mc Creery et al 1992).”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites Robblee and Rose 1990
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites Mc Creery et al 1992
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
Interpretationown data§ Abstract · p. 2Intrafascicular electrodes (TIME and LIFE) excite only the nerve fibers within the fascicle in which they are implanted and do not spread excitation across the perineurial barrier to nearby fascicles, at least at low stimulation intensities.
“intrafascicular electrodes (LIFE and TIME) provide excitation circumscribed to the implanted fascicle”
- Also stated in: § 3. Results · p. 6 · boosted
“These observations prove that an intrafascicular electrode provides excitation circumscribed to the nerve fibers contained in that fascicle, but does not extend stimulation to other nearby fascicles crossing the perineurial barrier, at least at low intensity stimulation levels.”
Quote in the paperSubstantial claim- Rests on an assumption: The rat sciatic nerve is a valid model for evaluating the selective stimulation properties of nerve electrodes intended for neuroprosthetic applications.
- Also stated in: § 3. Results · p. 6 · boosted
Classified as probably not a substantial claim.
Interpretationreasoning§ 4.2. Selectivity of stimulation · p. 12By repositioning the TIME short distances in the transversal direction, the selectivity of single active sites may be considerably improved.
“By repositioning the TIME short distances in the transversal direction, the selectivity of single active sites may be considerably improved”
Quote in the paperSubstantial claimMay combine two claims.
Interpretationcitation§ 4.2. Selectivity of stimulation · p. 12To achieve a selective interfacing with several nerve fascicles, a corresponding number of LIFEs needs to be implanted, whereas only one TIME may provide the same results.
“though the LIFE has a high degree of selectivity (Yoshida et al 2000), to achieve a selective interfacing with several nerve fascicles a corresponding number of LIFEs needs to be implanted, whereas only one TIME may provide the same results”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Yoshida et al 2000 source
Classified as probably not a substantial claim. May combine two claims.
Premisecitation§ 1. Introduction · p. 3The TIME is designed to be inserted transversally into the nerve and to address several fascicles or subgroups of fibers with a single device.
“A new electrode concept of a transversal intrafascicular multichannel electrode (TIME) is intended to be implanted transversally in the nerve and address several fascicles or subgroups of nerve fibers with one device (Boretius et al 2010).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Boretius et al 2010 source
May combine two claims.
Premisecitation§ 4.1. Stimulation threshold for activation · p. 11The motor fibers innervating the intrinsic muscles of the foot are distributed in a large central area in comparison with the motor fibers innervating the GM muscle, which are grouped at the periphery of the tibial nerve.
“The motor fibers innervating the intrinsic muscles of the foot are distributed in a large central area in comparison with the motor fibers innervating the GM muscle, which are grouped at the periphery of the tibial nerve (Badia et al 2010).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Badia et al 2010 source
Probably not a substantial claim: may not pass S4 (based).
Premisenone given§ 4.2. Selectivity of stimulation · p. 12The SId calculated by (2) takes into account the potential selectivity of a single electrode with multiple contacts to activate a set of target muscles.
“The SId calculated by (2) takes into account the potential selectivity of a single electrode with multiple contacts to activate a set of target muscles.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S2 (checkable).
Premisereasoning§ 4. Discussion · p. 9The selection of a suitable electrode has to take into account that the goal is achieving the highest selectivity for a high number of nerve fascicles with the least invasiveness and potential damage to the nerve.
“The selection of a suitable electrode has to take into account that the goal is achieving the highest selectivity for a high number of nerve fascicles with the least invasiveness and potential damage to the nerve.”
Quote in the paperNot a substantial claimClassified as probably not a substantial claim.
Premisecitation§ 4.2. Selectivity of stimulation · p. 12The recordings of the evoked CMAPs are useful to know the degree of activation in each of the muscles recorded under varying stimulus conditions.
“The recordings of the evoked CMAPs are useful to know the degree of activation in each of the muscles recorded under varying stimulus conditions.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Premisenone given§ 4. Discussion · p. 11The three types of electrode used need a surgical procedure for implantation.
“Regarding the issue of invasivity and potential nerve damage, the three types of electrode used need a surgical procedure for implantation”
Quote in the paperNot a substantial claimClassified as probably not a substantial claim.
Premisenone given§ 4.2. Selectivity of stimulation · p. 12Another approach to selective activation of multiple muscles with a single implant is the use of microelectrodes that penetrate the implanted nerves.
“Another approach to selective activation of multiple muscles with a single implant is the use of microelectrodes that penetrate the implanted nerves.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based). May combine two claims.
Interpretationnone given§ 4.2. Selectivity of stimulation · p. 12True multipolar stimulation with current distributions among all the poles of the TIME may provide further selectivity and robustness against misplacement.
“True multipolar stimulation with current distributions among all the poles of the TIME may provide further selectivity and robustness against misplacement.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S2 (checkable), S4 (based).
Premisenone given§ 4. Discussion · p. 9For restoration of motor function of the limbs, coordinated control over many muscles is necessary.
“For restoration of motor function of the limbs, coordinated control over many muscles is necessary.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S2 (checkable).
Premisereasoning§ 4. Discussion · p. 9A neural interface is needed that can selectively activate different fascicles in the nerve that each innervate a different muscle.
“Therefore, a neural interface is needed that can selectively activate different fascicles in the nerve that each innervate a different muscle.”
Quote in the paperNot a substantial claim
The paper relies on this without support.
The rat sciatic nerve is a valid model for evaluating the selective stimulation properties of nerve electrodes intended for neuroprosthetic applications.
“The electrodes were implanted on the rat sciatic nerve, and the activation of gastrocnemius, plantar and tibialis anterior muscles was recorded by EMG signals.”
The paper relies on this without support.
The cuff electrode is less invasive with respect to the nerve than the intraneural LIFE and TIME.
“although the cuff electrode is less invasive with respect to the nerve than the intraneural LIFE and TIME.”
The paper relies on this without support.
The rat sciatic nerve model is representative of larger nerves in bigger animals or humans for the purpose of evaluating electrode selectivity.
“For implants in larger nerves of bigger animals or humans, the intraneural segment of the TIME can be designed longer and with more active contacts, therefore increasing the number of nerve fascicles that may be selectively interfaced with respect to the rat model used in this study.”
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Other electrode designs used within peripheral nerve are less specific but allow access to a greater proportion of the nerve via electrical stimulation.
“other electrode designs used within peripheral nerve are less specific but allow access to a greater proportion of the nerve via electrical stimulation [33].”
From Fascicle specific targeting for selective peripheral nerve stimulation (2019) · cites this paper as [33]
The Introduction (p. 3) says intrafascicular positioning enhances selectivity, while TIME’s distributed sites let it access several fascicles. The Selectivity of stimulation section (p. 12) reports that TIME had higher selectivity than both LIFE and cuff electrodes. Thus, the intraneural design with broader access was not less selective in this comparison; the less-selective cuffs are placed around, not within, the nerve. (LLM, conf=0.82)
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredIn a study comparing multipolar cuff electrode, LIFE, and TIME, TIME was the only electrode to selectively stimulate at both interfascicular and intra-fascicular levels, whereas LIFE stimulated selectively at the intra-fascicular level and cuff electrode allowed selectivity at the interfascicular level.
“In a study comparing the multipolar cuff electrode, LIFE, and TIME, TIME was found to be the only electrode to selectively stimulate at both interfascicular and intra-fascicular levels, whereas LIFE was stimulating selectively at the intra-fascicular level and cuff electrode was allowing selectivity in interfascicular level [155].”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [155]
Cites
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · see citing works
Self-citationPaternostro-Sluga, T., Grim-Stieger, M., Posch, M., Schuhfried, O., Vacariu, G., Mittermaier, C., Bittner, C., & Fialka-Moser, V (2008) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-0235 · Cited by 652 · see citing works
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 470 · see citing works
Self-citationFunctionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398 · see citing works
Selective Stimulation of Cat Sciatic Nerve Using an Array of Varying-Length Microelectrodes
Branner, A., Stein, R. B., & Normann, R. A. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.85.4.1585 · Cited by 358 · see citing works
Selective control of muscle activation with a multipolar nerve cuff electrode
Veraart, C., Grill, W. M., & Mortimer, J. T. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.237694 · Cited by 320 · see citing works
Neural prostheses : fundamental studies
Agnew, W. F., & McCreery, D. B. (1990) · Medical Entomology and Zoology · Cited by 316 · see citing works
The Effect of Stimulus Parameters on the Recruitment Characteristics of Direct Nerve Stimulation
Gorman, P. H., & Mortimer, J. T. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325041 · Cited by 313 · see citing works
Lago, N., Yoshida, K., Koch, K. P., & Navarro, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886617 · Cited by 227 · see citing works
Self-citationThe effect of stimulus pulse duration on selectivity of neural stimulation
Grill, W. M., & Mortimer, J. T. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.481985 · Cited by 215 · see citing works
Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes
Yoshida, K., & Horch, K. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.243412 · Cited by 208 · see citing works
Polyimide cuff electrodes for peripheral nerve stimulation
Rodri´guez, F. J., Ceballos, D., Schu¨ttler, M., Valero, A., Valderrama, E., Stieglitz, T., & Navarro, X. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00192-8 · Cited by 207 · see citing works
Self-citationSchiefer, M. A., Triolo, R. J., & Tyler, D. J. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.918425 · Cited by 148 · see citing works
Quantification of recruitment properties of multiple contact cuff electrodes
Grill, W. M., & Mortimer, J. T. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.506402 · Cited by 136 · see citing works
Crago, P. E., Peckham, P. H., Mortimer, J. T., & Van Der Meulen, J. P. (1974) · Annals of Biomedical Engineering · doi:10.1007/bf02368496 · Cited by 133 · see citing works
Selective stimulation of the human femoral nerve with a flat interface nerve electrode
Schiefer, M. A., Polasek, K. H., Triolo, R. J., Pinault, G. C. J., & Tyler, D. J. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026006 · Cited by 130 · see citing works
Implantable electrical and mechanical interfaces with nerve and muscle
Hoffer, J. A., & Loeb, G. E. (1980) · Annals of Biomedical Engineering · doi:10.1007/bf02363438 · Cited by 121 · see citing works
Micera, S., Navarro, X., Carpaneto, J., Citi, L., Tonet, O., Rossini, P. M., Carrozza, M. C., Hoffmann, K. P., Vivo, M., Yoshida, K., et al. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2006207 · Cited by 120 · see citing works
Self-citationHaugland, M. K., Lickel, A., Haase, J., & Sinkjær, T. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.769412 · Cited by 112 · see citing works
Human nerve stimulation thresholds and selectivity using a multi-contact nerve cuff electrode
Polasek, K. H., Hoyen, H. A., Keith, M. W., & Tyler, D. J. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891383 · Cited by 111 · see citing works
Tarler, M. D., & Mortimer, J. T. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.828415 · Cited by 110 · see citing works
Gustafson, K. J., Pinault, G. C. J., Neville, J. J., Syed, I., Jr, J. A. D., Jean-Claude, J., & Triolo, R. J. (2009) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2008.08.0097 · Cited by 107 · see citing works
Badia, J., Boretius, T., Pascual-Font, A., Udina, E., Stieglitz, T., & Navarro, X. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2153850 · Cited by 103 · see citing works
Self-citationTopographical distribution of motor fascicles in the sciatic‐tibial nerve of the rat
Badia, J., Pascual‐Font, A., Vivó, M., Udina, E., & Navarro, X. (2010) · Muscle & Nerve · doi:10.1002/mus.21652 · Cited by 98 · see citing works
Self-citationMcCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. A. (1992) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446202 · Cited by 97 · see citing works
A modeling study of nerve fascicle stimulation
Veltink, P. H., van Veen, B. K., Struijk, J. J., Holsheimer, J., & Boom, H. B. K. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.32100 · Cited by 95 · see citing works
Fabrication and characteristics of an implantable, polymer-based, intrafascicular electrode
Lawrence, S. M., Dhillon, G. S., & Horch, K. W. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(03)00231-0 · Cited by 93 · see citing works
H reflex restitution and facilitation after different types of peripheral nerve injury and repair
Valero‐Cabré, A., & Navarro, X. (2001) · Brain Research · doi:10.1016/s0006-8993(01)03052-9 · Cited by 88 · see citing works
Self-citationA distributed architecture for activating the peripheral nervous system
Andreu, D., Guiraud, D., & Souquet, G. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/2/026001 · Cited by 69 · see citing works
Self-citationChapter 2 Bidirectional Interfaces with the Peripheral Nervous System
Micera, S., & Navarro, X. (2009) · International Review of Neurobiology · doi:10.1016/s0074-7742(09)86002-9 · Cited by 69 · see citing works
Self-citationSelective fascicular stimulation of the rat sciatic nerve with multipolar polyimide cuff electrodes
Navarro, X., Valderrama, E., Stieglitz, T., & Schüttler, M. (2001) · Restorative Neurology and Neuroscience · doi:10.3233/rnn-2001-00161 · Cited by 60
Self-citationRestoration of Lateral Hand Grasp Using Natural Sensors
Haugland, M. K., Lickel, A., Riso, R., Adamczyk, M. M., Keith, M. W., Johansen, I. L., Haase, J., & Sinkjær, T. (1997) · Artificial Organs · doi:10.1111/j.1525-1594.1997.tb04661.x · Cited by 52 · see citing works
(2001) · PubMed · Cited by 52 · see citing works
(2000) · PubMed · Cited by 50 · see citing works
Intrafascicular electrodes for stimulation and recording from mudpuppy spinal roots
Yoshida, K., Jovanović, K., & Stein, R. B. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(99)00176-4 · Cited by 49 · see citing works
Navarro, X., Lago, N., Vivo, M., Yoshida, K., Koch, K. P., Poppendieck, W., & Micera, S. (2007) · 2007 IEEE 10th International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428492 · Cited by 36 · see citing works
Self-citationICFEM 2000. Third IEEE International Conference on Formal Engineering Methods
(2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.867869 · Cited by 20 · see citing works
Deurloo, K. E. I., Holsheimer, J., & Bergveld, P. (2003) · Neuromodulation: Technology at the Neural Interface · doi:10.1046/j.1525-1403.2003.03034.x · Cited by 20 · see citing works
Selective and Graded Recruitment of Cat Hamstring Muscles With Intrafascicular Stimulation
Dowden, B. R., Wilder, A. M., Hiatt, S. D., Normann, R. A., Brown, N. A. T., & Clark, G. A. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2011988 · Cited by 19 · see citing works
Stieglitz, T., Schuettler, M., Schneider, A., Valderrama, E., & Navarro, X. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.819793 · Cited by 19 · see citing works
Self-citationWalter, J. S., Griffith, P., Sweeney, J., Scarpine, V., Bidnar, M., McLane, J. A., & Robinson, C. J. (1997) · Journal of Spinal Cord Medicine · doi:10.1080/10790268.1997.11719475 · Cited by 18 · see citing works
A Neural Stimulator Output Stage for Dodecapolar Electrodes
Soulier, F., Lerat, J.-B., Gouyet, L., Bernard, S., & Cathébras, G. (2008) · IEEE Computer Society Annual Symposium on VLSI · doi:10.1109/isvlsi.2008.84 · Cited by 7 · see citing works
Computer-based remote programming and control of stimulation units
Passama, R., Andreu, D., & Guiraud, D. (2011) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2011.5910604 · Cited by 6 · see citing works
Self-citationUntitled work
Badia, J. (2011) · IEEE Trans. Biomed. Eng.
UnresolvedUntitled work
S, N. X. L. N. V. M. Y. K. K. K. P. P. W. M. (2007) · Proc. IEEE 10th Int. Conf. on Rehabilitation Robotics (Noordwijk)
UnresolvedUntitled work
Navarro, X. (2001) · Restor. Neurol. Neurosci.
UnresolvedUntitled work
D, P. R. A. D. G. (2011) · 5th Int. IEEE EMBS Conf. on Neural Engineering
UnresolvedUntitled work
S, R. L. (1990) · Neural Prostheses: Fundamental Studies
UnresolvedUntitled work
G, S. F. L. J. B. G. L. B. S. C. (2008) · ISVLSI'08: IEEE Computer Society Annu. Symp. on VLSI
UnresolvedUntitled work
B, S. R. (1992) · Neural Prostheses: Replacing Motor Functions after Disease or Disability
Unresolved
Flagged first, then by citations
7 of the 42 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454 · see citing works
Peterchev, A. V., Wagner, T. A., Miranda, P. C., Nitsche, M. A., Paulus, W., Lisanby, S. H., Pascual‐Leone, Á., & Bikson, M. (2011) · Brain stimulation · doi:10.1016/j.brs.2011.10.001 · Cited by 433 · see citing works
Long-term usability and bio-integration of polyimide-based intra-neural stimulating electrodes
Wurth, S., Capogrosso, M., Raspopovic, S., Gandar, J., Federici, G., Kinany, N., Cutrone, A., Piersigilli, A., Pavlova, N., Guiet, R., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.01.014 · Cited by 176 · see citing works
Self-citationA review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133 · see citing works
Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review
Yildiz, K. A., Shin, A. Y., & Kaufman, K. R. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00667-5 · Cited by 113 · see citing works
Peterchev, A. V., D’Ostilio, K., Rothwell, J. C., et al. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/056023 · Cited by 111 · see citing works
Chronic interfacing with the autonomic nervous system using carbon nanotube (CNT) yarn electrodes
McCallum, G. A., Sui, X., Qiu, C., Marmerstein, J., Zheng, Y., Eggers, T. E., Hu, C., Dai, L., & Durand, D. M. (2017) · Scientific Reports · doi:10.1038/s41598-017-10639-w · Cited by 102 · see citing works
Interfaces with the Peripheral Nerve for the Control of Neuroprostheses
del Valle, J., & Navarro, X. (2013) · International Review of Neurobiology · doi:10.1016/b978-0-12-420045-6.00002-x · Cited by 105 · see citing works
Self-citationBadia, J., Boretius, T., Pascual-Font, A., Udina, E., Stieglitz, T., & Navarro, X. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2153850 · Cited by 103 · see citing works
Self-citationThin film multi-electrode softening cuffs for selective neuromodulation
González-González, M. A., Kanneganti, A., Joshi-Imre, A., Hernandez-Reynoso, A. G., Bendale, G., Modi, R., Ecker, M., Khurram, A., Cogan, S. F., Voit, W. E., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-34566-6 · Cited by 97 · see citing works
Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review.
Ghafoor, U., Kim, S., & Hong, K.-S. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00059 · Cited by 88 · see citing works
“Selective stimulation and recording have been achieved through TIME at both intra-fascicular and inter-fascicular levels (Badia et al., 2011a, 2016).”
Flexible and highly biocompatible nanofiber-based electrodes for neural surface interfacing
Heo, D. N., Kim, H.-J., Lee, Y. J., Heo, M., Lee, S. J., Lee, D., Do, S. H., Lee, S. H., & Kwon, I. K. (2017) · ACS Nano · doi:10.1021/acsnano.6b08390 · Cited by 86 · see citing works
A three-dimensional self-opening intraneural peripheral interface (SELINE)
Cutrone, A., Valle, J. D., Santos, D., Badia, J., Filippeschi, C., Micera, S., Navarro, X., & Bossi, S. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016016 · Cited by 82 · see citing works
Self-citationKundu, A., Harreby, K. R., Yoshida, K., Boretius, T., Stieglitz, T., & Jensen, W. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2267936 · Cited by 83 · see citing works
Self-citationSpatially selective activation of the visual cortex via intraneural stimulation of the optic nerve
Gaillet, V., Cutrone, A., Artoni, F., Vagni, P., Mega Pratiwi, A., Romero, S. A., Lipucci Di Paola, D., Micera, S., & Ghezzi, D. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0446-8 · Cited by 73 · see citing works
Sapkota, J., Kumar, S., Weder, C., & Foster, E. J. (2015) · Macromolecular Materials and Engineering · doi:10.1002/mame.201400313 · Cited by 80 · see citing works
Delivopoulos, E., Chew, D. J., Minev, I. R., Fawcett, J. W., & Lacour, S. P. (2012) · Lab on a Chip · doi:10.1039/c2lc21277c · Cited by 68 · see citing works
Kobelt, L. J., Wilkinson, A. E., McCormick, A. M., Willits, R., & Leipzig, N. D. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1058-9 · Cited by 68 · see citing works
Badia, J., Raspopovic, S., Carpaneto, J., Micera, S., & Navarro, X. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2440768 · Cited by 65 · see citing works
Self-citationRaspopovic, S., Capogrosso, M., Badia, J., Navarro, X., & Micera, S. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2189021 · Cited by 63 · see citing works
Self-citationMotor-commands decoding using peripheral nerve signals: a review
Hong, K.-S., Aziz, N., & Ghafoor, U. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab383 · Cited by 63 · see citing works
Čvančara, P., Boretius, T., López-Álvarez, V. M., Maciejasz, P., Andreu, D., Raspopovic, S., Petrini, F., Micera, S., Granata, G., Fernandez, E., et al. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab9a9a · Cited by 58 · see citing works
Self-citationGiagka, V., & Serdijn, W. A. (2018) · Bioelectronic Medicine · doi:10.1186/s42234-018-0010-y · Cited by 58 · see citing works
Schiefer, M. A., Freeberg, M., Pinault, G. J. C., Anderson, J., Hoyen, H., Tyler, D. J., & Triolo, R. J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/5/056006 · Cited by 57 · see citing works
Schiefer, M. A., Tyler, D. J., & Triolo, R. J. (2012) · Journal of Computational Neuroscience · doi:10.1007/s10827-011-0381-5 · Cited by 53 · see citing works
Electrospun hyaluronic acid-carbon nanotube nanofibers for neural engineering
Steel, E. M., Azar, J.-Y., & Sundararaghavan, H. G. (2019) · Materialia · doi:10.1016/j.mtla.2019.100581 · Cited by 48 · see citing works
Christensen, M. B., Wark, H. A. C., & Hutchinson, D. T. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2015.11.012 · Cited by 49 · see citing works
Fascicle specific targeting for selective peripheral nerve stimulation
Overstreet, C. K., Cheng, J., & Keefer, E. W. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab4370 · Cited by 46 · see citing works
Thota, A. K., Kuntaegowdanahalli, S., Starosciak, A. K., Abbas, J. J., Orbay, J., Horch, K. W., & Jung, R. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.07.020 · Cited by 41 · see citing works
Boretius, T., Yoshida, K., Badia, J., Harreby, K., Kundu, A., Navarro, X., Jensen, W., & Stieglitz, T. (2012) · 2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2012.6290787 · Cited by 39 · see citing works
Self-citationFascicular nerve stimulation and recording using a novel double-aisle regenerative electrode
Delgado-Martínez, I., Righi, M., Santos, D., Cutrone, A., Bossi, S., D’Amico, S., Del Valle, J., Micera, S., & Navarro, X. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6bac · Cited by 35 · see citing works
Self-citationLong-term functionality of transversal intraneural electrodes is improved by dexamethasone treatment
de la Oliva, N., del Valle, J., Delgado-Martinez, I., Mueller, M., Stieglitz, T., & Navarro, X. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2897256 · Cited by 26 · see citing works
Self-citationGore, R. K., Choi, Y., Bellamkonda, R., & English, A. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016017 · Cited by 26 · see citing works
Stoyanova, I. I., van Wezel, R. J. A., & Rutten, W. L. C. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066018 · Cited by 18 · see citing works
Čvančara, P., Valle, G., Müller, M., Guiho, T., Hiairrassary, A., Petrini, F., Raspopovic, S., Strauss, I., Granata, G., Fernandez, E., et al. (2019) · doi:10.1101/653964 · Cited by 12 · see citing works
Self-citationStieglitz, T., Boretius, T., Navarro, X., Badia, J., Guiraud, D., Divoux, J.-L., Micera, S., Rossini, P. M., Yoshida, K., Harreby, K. R., et al. (2012) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2011-0140 · Cited by 11 · see citing works
Self-citationActive Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review
Habibollahi, M., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3430038 · Cited by 11 · see citing works
“…is made above the outer layer of the nerve (epineurium), (2) intra-fascicular or intra-neural, which tap into the nerve fascicles with penetrative structures [20], [21], and (3) regenerative, where the interface architecture requires axonal growth through fine-scale device geometries [22], [23].”
Advanced 56 Channels Stimulation System to Drive Intrafascicular Electrodes
Guiho, T., Andreu, D., López-Álvarez, V. M., Čvančara, P., Hiairrassary, A., Granata, G., Wauters, L., Jensen, W., Divoux, J., Micera, S., et al. (2016) · Biosystems & biorobotics · doi:10.1007/978-3-319-46669-9_122 · Cited by 9 · see citing works
Self-citationMechanism of peripheral nerve modulation and recent applications
Shin, H., Kang, M., & Lee, S. (2021) · International Journal of Optomechatronics · doi:10.1080/15599612.2021.1978601 · Cited by 9 · see citing works
Zhen, G., Chen, H., Tsai, S., Zhang, J., Chen, T., & Jia, X. (2019) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.34135 · Cited by 7 · see citing works
Wu, Y., & Guo, L. (2020) · Neural Interface Engineering · doi:10.1007/978-3-030-41854-0_5 · Cited by 3 · see citing works
- Authors
- Badia, J., Boretius, T., Andreu, D., Azevedo-Coste, C., Stieglitz, T., & Navarro, X.
- Affiliations
- University of Freiburg (DE)
- Centre National de la Recherche Scientifique (FR)
- Universitat Autònoma de Barcelona (ES)
- Corresponding author
- Stieglitz, Thomas
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2011-05-11
- Volume
- 8
- Issue
- 3
- Pages
- 036023
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2049483283
- Cited by
- 227
- References
- 42
- Citations by year
- 2026: 6 · 2025: 13 · 2024: 21 · 2023: 19 · 2022: 11 · 2021: 22 · 2020: 18 · 2019: 18 · 2018: 15 · 2017: 17 · 2016: 14 · 2015: 16 · 2014: 10 · 2013: 15 · 2012: 8
- FWCI
- 4.90
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Centro de Investigación Biomédica en Red sobre Enfermedades Neurodegenerativas
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Keywords
- cuff electrodes, selective nerve stimulation, peripheral nerve stimulation, sciatic nerve, neuroprosthetics, electromyography, gastrocnemius, tibialis anterior, plantar muscles, rats
- MeSH terms
- Animals, Electric Stimulation, Electrodes, Implanted, Equipment Design, Muscle Contraction, Sciatic Nerve, Rats, Sprague-Dawley, Muscle, Skeletal, Equipment Failure Analysis, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-10-01.
Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-10-01.
Cited sources are checked by gpt-6-sol.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review