The WalkTrainer—A New Generation of Walking Reeducation Device Combining Orthoses and Muscle Stimulation
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
This paper presents a novel reeducation device for paraplegics that combines hybrid orthoses and closed-loop electrical muscle stimulation. Based on the so called Cyberthosis concept, the WalkTrainer enables an active muscular participation of the subject in the walking reeducation process by the mean of closed-loop muscle stimulation. The WalkTrainer is also equipped with a leg and pelvic orthosis, an active bodyweight support, and motorized wheels to allow true over ground deambulation. This paper will focus on the development of the WalkTrainer, the presentation of the control strategies, and also give some preliminary results of the first clinical trials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modelling and Control of Robot Manipulators
Sciavicco, L., & Siciliano, B. (2000) · Advanced Textbooks in Control and Signal Processing · doi:10.1007/978-1-4471-0449-0 · Cited by 1,701
Neuromuscular electrical stimulation in neurorehabilitation
Sheffler, L. R., & Chae, J. (2007) · Muscle & Nerve · doi:10.1002/mus.20758 · Cited by 529 · cited 1×
“Muscle stimulation is commonly used in clinical environments, mainly for strengthening purposes but also for prevention of disuse atrophy and in neurological field for muscles contractures prevention, regulation of spasticity, and improvement of function [20], [ 21 ].”
MethodModelling and Control of Robot Manipulators
Siciliano, L. S. A. B. (2000) · Measurement Science and Technology · doi:10.1088/0957-0233/11/12/709 · Cited by 425
Clinical Gait Analysis: Theory and Practice
Kirtley, C. (2006) · Cited by 373
Clinical gait analysis. Theory and practice
Maceira-Suárez, E. (2006) · Revista del Pie y Tobillo · Cited by 341
Bélanger, M., Stein, R. B., Wheeler, G. D., Gordon, T., & Leduc, B. (2000) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2000.7170 · Cited by 318 · cited 1×
“Thus, the advantages of a perfectly controlled robotic treatment are combined with the benefits provided by electrical-stimulated physical activity [ 7 ], [8].”
BackgroundAutomatic Gait-Pattern Adaptation Algorithms for Rehabilitation With a 4-DOF Robotic Orthosis
Jezernik, S., Colombo, G., & Morari, M. (2004) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2004.825515 · Cited by 312
Hemiparetic stroke impairs anticipatory control of arm movement
Takahashi, C. D., & Reinkensmeyer, D. J. (2003) · Experimental Brain Research · doi:10.1007/s00221-002-1340-1 · Cited by 157 · cited 1×
“Thus, the advantages of a perfectly controlled robotic treatment are combined with the benefits provided by electrical-stimulated physical activity [7], [ 8 ].”
BackgroundEmken, J. L., Bobrow, J. E., & Reinkensmeyer, D. J. (2005) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2005.1501108 · Cited by 142 · cited 1×
“In most cases, however, these robotic rehabilitation devices only provide motion, this motion can be fixed (i.e., imposed in a so called passive way) or controlled to make the training more interactive, this lead to the assist as needed paradigm [ 4 ], [5].”
BackgroundInvestigation of the Hammerstein hypothesis in the modeling of electrically stimulated muscle
Hunt, K. J., Munih, M., Donaldson, N., & Barr, F. M. D. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.704868 · Cited by 138 · cited 1×
“1) Muscle Model and Identification: A first muscle model dependent of the muscle stimulation, position, and velocity has been implemented [26]–[ 28 ].”
MethodWheeler, G. D., Andrews, B., Lederer, R., Davoodi, R., Natho, K. E., Weiss, C., Jeon, J. Y., BHAMBHANI, Y. N., & Steadward, R. D. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2002.33656 · Cited by 128 · cited 1×
“Muscle stimulation has been implemented for cycling [22], rowing [ 23 ], and also walking [24], [25].”
MethodGlinsky, J. V., Harvey, L. A., & van Es, P. (2007) · Physiotherapy Research International · doi:10.1002/pri.375 · Cited by 118 · cited 1×
“Muscle stimulation is commonly used in clinical environments, mainly for strengthening purposes but also for prevention of disuse atrophy and in neurological field for muscles contractures prevention, regulation of spasticity, and improvement of function [ 20 ], [21].”
MethodDriven gait orthosis to do locomotor training of paraplegic patients
Colombo, G., Jorg, M., & Dietz, V. (2002) · Proceedings of the 22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (Cat. No.00CH37143) · doi:10.1109/iembs.2000.901556 · Cited by 72 · cited 1×
“beeing developped (Lokomat [ 2 ], Autoambulator, POGO [3]).”
Pelvic Exercise and Gait in Hemiplegia
Trueblood, P. R., Walker, J. M. T., Perry, J., & Gronley, J. K. (1989) · Physical Therapy · doi:10.1093/ptj/69.1.18 · Cited by 64
Robotics for Gait Training After Spinal Cord Injury
Galvez, J., & Reinkensmeyer, D. J. (2005) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/damj-g43a-16eh-1bdk · Cited by 43 · cited 1×
“beeing developped (Lokomat [2], Autoambulator, POGO [ 3 ]).”
Stein, R. B., Chong, S. L., James, K. B., & Bell, G. J. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.24014 · Cited by 26 · cited 1×
“Muscle stimulation has been implemented for cycling [ 22 ], rowing [23], and also walking [24], [25].”
MethodCyberthosis: Rehabilitation Robotics With Controlled Electrical Muscle Stimulation
Métrailler, P., Brodard, R., Stauffer, Y., Clavel, R., & Frischknecht, R. (2007) · doi:10.5772/5167 · Cited by 16
Self-citation
Cited by
Review of control strategies for robotic movement training after neurologic injury
Marchal-Crespo, L., & Reinkensmeyer, D. J. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-20 · Cited by 1,182
Review of control strategies for lower-limb exoskeletons to assist gait
Baud, R., Manzoori, A. R., Ijspeert, A., & Bouri, M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00906-3 · Cited by 381
Self-citationHuman–Robot Interaction Control of Rehabilitation Robots With Series Elastic Actuators
Yu, H., Huang, S., Chen, G., Pan, Y., & Guo, Z. (2015) · IEEE Transactions on Robotics · doi:10.1109/tro.2015.2457314 · Cited by 356
Safety issues in human-robot interactions
Vasic, M., & Billard, A. (2013) · 2013 IEEE International Conference on Robotics and Automation · doi:10.1109/icra.2013.6630576 · Cited by 268
Powered exoskeletons for bipedal locomotion after spinal cord injury
Contreras-Vidal, J. L., A Bhagat, N., Brantley, J., Cruz-Garza, J. G., He, Y., Manley, Q., Nakagome, S., Nathan, K., Tan, S. H., Zhu, F., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/031001 · Cited by 216
“…years 10 mWT 6 minWT TUG 19 (Yang et al 2015) [NCT02118194] ReWalk 12–120 1–2.0 1 12 12 24–64 T4,T10,T4, C8/T8,T11, T5,T1,T9,T7, T2,T2,C8 1–16 X X — 20 (Stauffer et al 2009) WalkTrainer 12 1 1 12 6 — — — — — — 21 (Tanabe et al 2013a) WPAL 2–11 1 — — 7 32–61 T12,T12,T11, T9,T6,T6,T6 6–20 X — — 22…”
BackgroundInfluential
Metadata
- Authors
- Stauffer, Y., Allemand, Y., Bouri, M., Fournier, J., Clavel, R., Metrailler, P., Brodard, R., & Reynard, F.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2009-02
- Volume
- 17
- Issue
- 1
- Pages
- 38-45
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2141987834
- Cited by
- 163
- References
- 17
- FWCI
- 3.62
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.