CoChat

Online Myoelectric Control of a Dexterous Hand Prosthesis by Transradial Amputees

Cipriani, Christian, Antfolk, Christian, Controzzi, Marco, Lundborg, Göran, Rosen, Birgitta, Carrozza, Maria Chiara, Sebelius, Fredrik · 2011 · IEEE Transactions on Neural Systems and Rehabilitation Engineering

The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.

Abstract

A real-time pattern recognition algorithm based on k-nearest neighbors and lazy learning was used to classify, voluntary electromyography (EMG) signals and to simultaneously control movements of a dexterous artificial hand. EMG signals were superficially recorded by eight pairs of electrodes from the stumps of five transradial amputees and forearms of five able-bodied participants and used online to control a robot hand. Seven finger movements (not involving the wrist) were investigated in this study. The first objective was to understand whether and to which extent it is possible to control continuously and in real-time, the finger postures of a prosthetic hand, using superficial EMG, and a practical classifier, also taking advantage of the direct visual feedback of the moving hand. The second objective was to calculate statistical differences in the performance between participants and groups, thereby assessing the general applicability of the proposed method. The average accuracy of the classifier was 79% for amputees and 89% for able-bodied participants. Statistical analysis of the data revealed a difference in control accuracy based on the aetiology of amputation, type of prostheses regularly used and also between able-bodied participants and amputees. These results are encouraging for the development of noninvasive EMG interfaces for the control of dexterous prostheses.

Overview

Integrity signals

Registry

Crossref · 10.1109/tnsre.2011.2108667

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 37 references

Cited by

See all 233

Metadata

Authors
Cipriani, C., Antfolk, C., Controzzi, M., Lundborg, G., Rosen, B., Carrozza, M. C., & Sebelius, F.
Affiliations
  • Scuola Superiore Sant'Anna (IT)
  • Lund University (SE)
  • Skåne University Hospital (SE)
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2011-06
Volume
19
Issue
3
Pages
260-270
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2161493443
Cited by
233
References
37
Citations by year
2026: 3 · 2025: 11 · 2024: 7 · 2023: 8 · 2022: 19 · 2021: 11 · 2020: 18 · 2019: 26 · 2018: 22 · 2017: 20 · 2016: 17 · 2015: 18 · 2014: 22 · 2013: 15 · 2012: 11
FWCI
10.05
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
  • PubMed (publishedVersion)
  • BOA (University of Milano-Bicocca) (submittedVersion)
  • Lund University Publications (Lund University) (submittedVersion)
  • CINECA IRIS Institutional Research Information System (Sant'Anna School of Advanced Studies) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
Keywords
myoelectric control, transradial amputation, electromyography, k-nearest neighbors, lazy learning, real-time pattern recognition, finger movement classification, robotic hand control, visual feedback, prosthesis users
MeSH terms
Adult, Algorithms, Amputation, Surgical, Artificial Intelligence, Artificial Limbs, Computer Systems, Electromyography, Female, Fingers, Hand, Humans, Male, Middle Aged, Movement, Photic Stimulation, Prosthesis Design, Psychomotor Performance, Robotics, Feedback, Psychological, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Online Myoelectric Control of a Dexterous Hand Prosthesis by Transradial Amputees. https://app.cochat.ai/papers/10.1109/tnsre.2011.2108667
The paper
Cipriani, C., Antfolk, C., Controzzi, M., Lundborg, G., Rosen, B., Carrozza, M. C., & Sebelius, F. (2011). Online Myoelectric Control of a Dexterous Hand Prosthesis by Transradial Amputees. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2011.2108667

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.