Online Myoelectric Control of a Dexterous Hand Prosthesis by Transradial Amputees
The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
A real-time pattern recognition algorithm based on k-nearest neighbors and lazy learning was used to classify, voluntary electromyography (EMG) signals and to simultaneously control movements of a dexterous artificial hand. EMG signals were superficially recorded by eight pairs of electrodes from the stumps of five transradial amputees and forearms of five able-bodied participants and used online to control a robot hand. Seven finger movements (not involving the wrist) were investigated in this study. The first objective was to understand whether and to which extent it is possible to control continuously and in real-time, the finger postures of a prosthetic hand, using superficial EMG, and a practical classifier, also taking advantage of the direct visual feedback of the moving hand. The second objective was to calculate statistical differences in the performance between participants and groups, thereby assessing the general applicability of the proposed method. The average accuracy of the classifier was 79% for amputees and 89% for able-bodied participants. Statistical analysis of the data revealed a difference in control accuracy based on the aetiology of amputation, type of prostheses regularly used and also between able-bodied participants and amputees. These results are encouraging for the development of noninvasive EMG interfaces for the control of dexterous prostheses.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This strategy has provided reasonable signal amplitude and some control of a prosthetic limb in patients undergoing transradial amputations (24–28).”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [25]
In the citing paper
“In previous studies, investigators have provided prosthetic control signals by interfacing with intact muscles in the residual limb.”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [25]
Citations
Cites
(2012) · Encyclopedia of the Sciences of Learning · doi:10.1007/978-1-4419-1428-6_5195 · Cited by 19,370
Nearest neighbor pattern classification
Cover, T., & Hart, P. (1967) · IEEE Transactions on Information Theory · doi:10.1109/tit.1967.1053964 · Cited by 16,936 · cited 2×
“The k-nearest neighbors decision rule is the basis of a wellestablished, high performance pattern recognition technique [32], [33].”
MethodRussell, E. L., Chiang, L. H., & Braatz, R. D. (2000) · Advances in Industrial Control · doi:10.1007/978-1-4471-0409-4_3 · Cited by 7,862
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 1×
“While acquisition of invasive biosignals from the motor cortex may be suitable for tetraplegics [3], who have lost their ability to control the entirety of their upper limbs, and less invasive Online Myoelectric Control of a Dexterous Hand Prosthesis by Transradial Amputees”
BackgroundA new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743 · cited 4×
“movements unlike most of the pattern recognition systems developed earlier, where different hand functions (or grasps) are usually remapped to wrist movements [16], [18]-[20], [22].”
BackgroundMethodInfluentialAtkeson, C. G., Moore, A. W., & Schaal, S. (1997) · Artificial Intelligence Review · doi:10.1023/a:1006559212014 · Cited by 1,671 · cited 3×
“pattern recognition algorithms based on lazy learning [26] and sending real-time control commands to the hand.”
BackgroundMethodSynaesthesia in phantom limbs induced with mirrors
(1996) · Proceedings of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rspb.1996.0058 · Cited by 1,246 · cited 1×
“participant so that the right-hand prosthesis was reflected and visually superimposed as close as possible to the stump [34].”
MethodMyoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244 · cited 2×
“pattern recognition based algorithms [1], [6].”
BackgroundA wavelet-based continuous classification scheme for multifunction myoelectric control
Englehart, K., Hudgin, B., & Parker, P. A. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914793 · Cited by 697
Cited by
Items 201–233 of 233
Design of an Accessible, Powered Myoelectrically Controlled Hand Prosthesis
Akirmak, O. O., Tatar, Ç., Altun, Z. G., & Mishchenko, Y. (2017) · TEM Journal · doi:10.18421/tem63-07 · Cited by 2
“Significant work has been done on such systems in research literature [1-9] as well as myoelectric prostheses are now available commercially on the market including iLimb (Touch Bionics, UK), Michelangelo (Otto Bock Healthcare Product GmbH, Austria), Bebionic (Steeper Group, UK), and DEKA arm (Deka Integrated Solution…”
BackgroundEffect of user adaptation on prosthetic finger control with an intuitive myoelectric decoderPreprint
Krasoulis, A., Vijayakumar, S., & Nazarpour, K. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/585703 · Cited by 2
Osborn, L. E., Betthauser, J., & Thakor, N. V. (2019) · Wiley eBooks · doi:10.1002/047134608x.w1424.pub2 · Cited by 4
Wang, M. J., Cubillos, L. H., Kung, T. A., Kemp, S. W. P., Snyder‐Warwick, A. K., & Cederna, P. S. (2025) · Artificial Intelligence Surgery · doi:10.20517/ais.2025.03 · Cited by 2
Gesture-driven prosthetic hand: A real-time computer vision approach
Chandrasegar, P. N., Rajalakshmy, Ramanathan, S., Loganathan, S., & Scinduja, O. C. S. M. (2026) · AIP conference proceedings · doi:10.1063/5.0334878 · Cited by 1
Localisation method for sEMG electrode array, towards hand gesture recognition HMI development
Tomczyński, J., Mańkowski, T., & Kaczmarek, P. (2017) · Signal Processing: Algorithms, Architectures, Arrangements, and Applications · doi:10.23919/spa.2017.8166836 · Cited by 1
“EMG signals are widely used for hand prosthesis control applications [2] [3], including above-elbow amputees [4], and commercial prostheses like iLimb or BeBionic [5].”
Phukan, N., & Kakoty, N. M. (2018) · Advances in intelligent systems and computing · doi:10.1007/978-981-13-1708-8_6 · Cited by 1
Yu, X., Qian, J., Zhang, Z., Wu, Y., & Zhang, Z. (2019) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio49542.2019.8961687 · Cited by 1
“Researchers have studied a series of classification methods, including neural network [4], SVM [5], fuzzy method [21], random forest [22] and kNN [7].”
MethodLower Limbs Exoskeleton Control Strategy Based On Optimized Compliance Algorithm
Wang, F., Lignzhou, Y. U., Wu, H., & Shi, K. (2019) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio49542.2019.8961853 · Cited by 1
“However, previous studies have focus primarily on motion classification of upper limb discrete gestures[16][17].”
BackgroundPogarasteanu, M. E., Costea, R., Berami, A., Drignei, E., Moga, M., Raita, Ș. M., Bălăceanu, R. A., Ionaşcu, I., Barbilian, R. C., & Radu, F. I. (2019) · Revista de Chimie · doi:10.37358/rc.19.2.6996 · Cited by 1
KNN Learning Techniques for Proportional Myocontrol in Prosthetics
Sziburis, T., Nowak, M., & Brunelli, D. (2021) · Biosystems & biorobotics · doi:10.1007/978-3-030-70316-5_109 · Cited by 1
Smart sensing and actuators for people with hand motion impairment
Izdrui, D., Geman, O., Postolache, O. A., Elahi, H., Vicoveanu, D. I., & Curea, S. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-85174-9.00002-9 · Cited by 1
Pogarasteanu, M. E., Moga, M., Barbilian, A. G., Avram, G. M., Dascălu, M., Franti, E. D., Gheorghiu, N., Moldovan, C., Rusu, E. E., Adam, R., et al. (2023) · Bioengineering · doi:10.3390/bioengineering10030319 · Cited by 1
“Using a software environment is not singular [53,54] and offers the possibility of testing the subject’s ability to voluntarily control the musculature at the amputation site and, following the series of tests, choosing the subset of sEMG signals most useful in the use of a myoelectric prosthesis.”
MethodTemporal Feature Extraction for Improving Myoelectric based Recognition of Prosthetic Hand
Bhagwat, S., & Mukherji, P. (2020) · International Conference on Wireless Communications, Signal Processing and Networking (WiSPNET) · doi:10.1109/wispnet48689.2020.9198476 · Cited by 1
“Root Mean Square (RMS) [2,4,5] RMS = √√√√ 1 N N∑ i=1 x2i (2) iii.”
MethodInfluentialRestoring Fine Motor Prosthetic Hand Control via Peripheral Neural Technology
Vu, P. P. (2019) · Deep Blue (University of Michigan) · Cited by 1
Force estimation using an approximately physiological mechanism
Na, Y., & Kim, J. (2013) · International Conference on Ubiquitous Robots and Ambient Intelligence · doi:10.1109/urai.2013.6677458
CHANGES IN MUSCLE ACTIVITY PATTERN FOR HAND-ARM MOVEMENTS OF AMPUTEES AND NON-AMPUTEES
da Silva, I. C. M., & Bagesteiro, L. B. (2014)
Sensor Fusion for Closed-loop Control of Upper-limb Prostheses
Marković, M. (2016) · eDiss (Georg-August-Universität Göttingen) · doi:10.53846/goediss-5733 · Cited by 2
Optimisation of pre-set forearm EMG electrode combinations using principal component analysis
Fyvie, K. G. H. M. (2018)
GESTURE INTERACTION IN THE LIRKIS CAVE BASED ON EMG AND KINECT SENSOR
PASTORNICKY, P., & Chovanec, M. (2020) · Acta Electrotechnica et Informatica · doi:10.15546/aeei-2019-0024
“However, control difficulties, comfort problems, and high costs are still the main limitations of some commercial devices [7].”
BackgroundControl interfaces for active trunk support
Verros, S. (2020) · doi:10.3990/1.9789036549912
Advances in the mental control of a robotic hand
Ochoa, I. F. V., Angarita, R. C. B., & Cortés, C. A. P. (2020) · Ingenieria Solidaria · doi:10.16925/2357-6014.2020.02.10
“On the other hand, systems that use surface type electrodes [20] have the disadvantage that their performance is directly subject to the state of the muscle, the type of amputation and even the positioning of the electrodes [21].”
BackgroundEMG Driven Robotic-Aided Arm Rehabilitation
Bonilla, D., Colorado, J. D., Laribi, M. A., Sandoval, J., & Alvarado‐Rojas, C. (2022) · Mechanisms and machine science · doi:10.1007/978-3-031-04870-8_40
Intelligent Grasping Classification Method for a Smart Prosthetic Hand
Kaplanoğlu, E., Erdemir, E., Jones, A., Bailey, R., Kawamura, K., & Hargrove, S. K. (2018) · IEEE SoutheastCon · doi:10.1109/secon.2018.8479162
“Prosthetic devices have been developed for many years to help and compensate people who have lost their limbs to accidents or inherent defect disabilities to perform daily activities [1-3].”
BackgroundImplantable Neural Interfaces for Direct Control of Hand Prostheses
Vaskov, A. K. (2021) · Deep Blue (University of Michigan) · doi:10.7302/2843
Betancourth, D. S. B. (2022) · Repositorio Institucional (Pontificia Universidad Javeriana) · doi:10.11144/javeriana.10554.63723
A Soft Robotics Approach to Prosthetic Hands: Integrating 3D Printing Techniques and Embedded Vision
Khan, W. A., Farooq, U., Zeb, A., Awais, I., Tariq, M. Q., & Tiwana, M. I. (2024) · International Conference on Robotics and Automation in Industry (ICRAI) · doi:10.1109/icrai62391.2024.10894254
“Many researches have been conducted to make these prostheses human-friendly with human-machine interface (HMI) such as control of hand prosthesis with brain signals [9] or neuromuscular signals [10].”
Advancements in Intelligent Prosthesis Design through Human-Machine Interfaces
Dai, C. (2025) · Theoretical and Natural Science · doi:10.54254/2753-8818/2025.ad28736
Liang, T., Jia, H., Li, B., Chang, Z., Li, C., Guo, J., Zhang, K., Solé‐Casals, J., Kushihashi, Y., Himeno, R., et al. (2025) · Lecture notes in computer science · doi:10.1007/978-981-95-4381-6_31
Feldman, D. A., Cavinatto, D., Olsen, C. D., Hamrick, W. C., Paskett, M. D., Davis, T. S., Baschuk, C., Duncan, C. C., King, J. B., Clark, G. A., et al. (2025) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc58623.2025.11252908 · Cited by 1
“…among individuals with congenital amputation: congenital children fitted with a prosthetic at an early age are less likely to reject the prosthetic device, and congenital adults encounter added difficulty compared with traumatic amputees when learning to use prosthetics for the first time [1-3].”
Lukyanenko, P., Dewald, H. A., Lambrecht, J. M., Kirsch, R. F., Tyler, D. J., & Williams, M. R. (2021) · Figshare · doi:10.6084/m9.figshare.14247683
Reyes, D. A., & Humberto Loaiza, C. (2026) · Advances in Human-Computer Interaction · doi:10.1155/ahci/5237767
From muscles to motion: the role of sensor layout and physiological factors in hand motion decoding
Andreas, D., Dwivedi, A., Castellini, C., & Beckerle, P. (2026) · Scientific Reports · doi:10.1038/s41598-026-59979-6
Metadata
- Authors
- Cipriani, C., Antfolk, C., Controzzi, M., Lundborg, G., Rosen, B., Carrozza, M. C., & Sebelius, F.
- Affiliations
- Scuola Superiore Sant'Anna (IT)
- Lund University (SE)
- Skåne University Hospital (SE)
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2011-06
- Volume
- 19
- Issue
- 3
- Pages
- 260-270
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2161493443
- Cited by
- 233
- References
- 37
- Citations by year
- 2026: 3 · 2025: 11 · 2024: 7 · 2023: 8 · 2022: 19 · 2021: 11 · 2020: 18 · 2019: 26 · 2018: 22 · 2017: 20 · 2016: 17 · 2015: 18 · 2014: 22 · 2013: 15 · 2012: 11
- FWCI
- 10.05
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- BOA (University of Milano-Bicocca) (submittedVersion)
- Lund University Publications (Lund University) (submittedVersion)
- CINECA IRIS Institutional Research Information System (Sant'Anna School of Advanced Studies) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- myoelectric control, transradial amputation, electromyography, k-nearest neighbors, lazy learning, real-time pattern recognition, finger movement classification, robotic hand control, visual feedback, prosthesis users
- MeSH terms
- Adult, Algorithms, Amputation, Surgical, Artificial Intelligence, Artificial Limbs, Computer Systems, Electromyography, Female, Fingers, Hand, Humans, Male, Middle Aged, Movement, Photic Stimulation, Prosthesis Design, Psychomotor Performance, Robotics, Feedback, Psychological, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.