The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Preliminary Evaluation of a Powered Lower Limb Orthosis to Aid Walking in Paraplegic Individuals
Open accessAbstract
This paper describes a powered lower-limb orthosis that is intended to provide gait assistance to spinal cord injured (SCI) individuals by providing assistive torques at both hip and knee joints. The orthosis has a mass of 12 kg and is capable of providing maximum joint torques of 40 Nm with hip and knee joint ranges of motion from 105° flexion to 30° extension and 105° flexion to 10° hyperextension, respectively. A custom distributed embedded system controls the orthosis with power being provided by a lithium polymer battery which provides power for one hour of continuous walking. In order to demonstrate the ability of the orthosis to assist walking, the orthosis was experimentally implemented on a paraplegic subject with a T10 complete injury. Data collected during walking indicates a high degree of step-to-step repeatability of hip and knee trajectories (as enforced by the orthosis) and an average walking speed of 0.8 km/hr. The electrical power required at each hip and knee joint during gait was approximately 25 and 27 W, respectively, contributing to the 117 W overall electrical power required by the device during walking. A video of walking corresponding to the aforementioned data is included in the supplemental material.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The biomechanics and motor control of human gait : normal, elderly and pathological
Winter, D. A. (1991) · University of Waterloo Press eBooks · Cited by 1,428
Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,327
The biomechanics and motor control of human gait: Normal, elderly, and pathological
Brand, R. A. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90236-t · Cited by 1,103
The biomechanics and motor control of human gait
Winter, D. A. (1987) · University of Waterloo Press eBooks · Cited by 767
Exoskeletons and orthoses: classification, design challenges and future directions
Herr, H. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-21 · Cited by 477
Intention-based walking support for paraplegia patients with robot suit HAL
Suzuki, K., Mito, G., Kawamoto, H., Hasegawa, Y., & Sankai, Y. (2007) · Advanced Robotics · doi:10.1163/156855307781746061 · Cited by 474
Intention-Based Walking Support for Paraplegia Patients with Robot Suit HAL
Suzuki, K., Mito, G., Kawamoto, H., Hasegawa, Y., & Sankai, Y. (2010) · Climbing and Walking Robots · doi:10.5772/8835 · Cited by 400
Exoskeletons and robotic prosthetics: a review of recent developments
Bogue, R. (2009) · Industrial Robot: An International Journal · doi:10.1108/01439910910980141 · Cited by 348
Ragnarsson, K. T. (2008) · Spinal Cord · doi:10.1038/sj.sc.3102091 · Cited by 301
Sit-to-stand and stand-to-sit transfer support for complete paraplegic patients with robot suit HAL
Tsukahara, A., Kawanishi, R., Hasegawa, Y., & Sankai, Y. (2010) · Advanced Robotics · doi:10.1163/016918610x512622 · Cited by 269 · cited 1×
“In [29]–[32], the authors describe control methods for providing assistive maneuvers (sit-to-stand, stand-to-sit, and walking) to paraplegic individuals with the powered lower limb orthosis HAL, which is an emerging commercial device with (in the incarnation utilized in the aforementioned publications) six electric mo…”
Development of active anthropomorphic exoskeletons
Vukobratovic, M., Hristic, D., & Stojiljkovic, Z. (1974) · Medical & Biological Engineering · doi:10.1007/bf02629836 · Cited by 216
Sexual loss in relation to other functional losses for spinal cord injured males.
Rw, H., & Mr, F. (1976) · PubMed · Cited by 162
Standing-up motion support for paraplegic patient with Robot Suit HAL
Tsukahara, A., Hasegawa, Y., & Sankai, Y. (2009) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2009.5209567 · Cited by 120
Consumer perspectives on mobility: implications for neuroprosthesis design.
Brown-Triolo, D. L., Roach, M. J., Nelson, K. M., & Triolo, R. J. (2002) · PubMed · Cited by 112
Ruthenberg, B. J., Wasylewski, N. A., & Beard, J. E. (1997) · PubMed · Cited by 78
A two-degree-of-freedom motor-powered gait orthosis for spinal cord injury patients
Ohta, Y., Yano, H., Suzuki, R., Yoshida, M., Kawashima, N., & Nakazawa, K. (2007) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544119jeim55 · Cited by 76
Harvey, L. A., Davis, G. M., Smith, M. B., & Engel, S. (1998) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(98)90092-2 · Cited by 69
Kawashima, N., Sone, Y., Nakazawa, K., Akai, M., & Yano, H. (2003) · Spinal Cord · doi:10.1038/sj.sc.3101494 · Cited by 59
To, C. S., Kobetic, R., Schnellenberger, J. R., Audu, M., & Triolo, R. (2008) · IEEE/ASME transactions on mechatronics · doi:10.1109/tmech.2008.918551 · Cited by 49
Gait Evaluation of a Novel Hip Constraint Orthosis With Implication for Walking in Paraplegia
Audu, M. L., To, C. S., Kobetic, R., & Triolo, R. J. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2047594 · Cited by 47
Cooperative walk control of paraplegia patient and assistive system
Hasegawa, Y., Jang, J., & Sankai, Y. (2009) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2009.5354192 · Cited by 44
IJzerman, M. J., Baardman, G., Hermens, H. J., Veltink, P. H., Boom, H. B. K., & Zilvold, G. (1997) · Prosthetics and Orthotics International · doi:10.3109/03093649709164530 · Cited by 43
Baardman, G., IJzerman, M. J., Hermen, H. J., Veltink, P. H., Boom, H. B. K., & Zilvold, G. (1997) · Prosthetics and Orthotics International · doi:10.3109/03093649709164559 · Cited by 34
Energy consumption of paraplegic locomotion using reciprocating gait orthosis
Beillot, J., Carré, F., Claire, G. L., et al. (1996) · European Journal of Applied Physiology · doi:10.1007/bf02425502 · Cited by 25
Spinal Cord Injury: A Guide for Patient and Family
Phillips, L. D., Ozer, M. N., Axelson, P. W., Chizeck, H. J., Britell, C. W., Fonseca, J. J., Bayless, M. E., & Watson, H. E. (1987) · Cited by 20
Gustafson, N. (1988) · American Journal of Occupational Therapy · doi:10.5014/ajot.42.10.682a · Cited by 13
Cited by
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“Voice commands or eye movements sequences have also been demonstrated as possible ways to interact with P/O devices [78-80].”
State of the Art and Future Directions for Lower Limb Robotic Exoskeletons
Young, A. J., & Ferris, D. P. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2521160 · Cited by 901
Review of assistive strategies in powered lower-limb orthoses and exoskeletons
Yan, T., Cempini, M., Oddo, C. M., & Vitiello, N. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.09.032 · Cited by 715
A Review on Lower Limb Rehabilitation Exoskeleton Robots
Shi, D., Zhang, W., Zhang, W., & Ding, X. (2019) · Chinese Journal of Mechanical Engineering · doi:10.1186/s10033-019-0389-8 · Cited by 508
Systematic review on wearable lower-limb exoskeletons for gait training in neuromuscular impairments
Rodríguez-Fernández, A., Lobo-Prat, J., & Font-Llagunes, J. M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00815-5 · Cited by 435
Metadata
- Authors
- Farris, R. J., Quintero, H. A., & Goldfarb, M.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2011-12
- Volume
- 19
- Issue
- 6
- Pages
- 652-659
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2006355360
- Cited by
- 342
- References
- 26
- FWCI
- 12.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.