Seizure Prediction Using Spike Rate of Intracranial EEG
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Reliable prediction of forthcoming seizures will be a milestone in epilepsy research. A method capable of timely predicting the occurrence of seizures could significantly improve the quality of life for epilepsy patients and open new therapeutic approaches. Seizures are usually characterized by generalized spike wave discharges. With the advent of seizures, the variation of spike rate (SR) will have different manifestations. In this study, a seizure prediction approach based on spike rate is proposed and evaluated. Firstly, a low-pass filter is applied to remove the high frequency artifacts in electroencephalogram (EEG). Then, the morphology filter is used to detect spikes and compute SR, and SR is smoothed with an average filter. Finally, the performance of smoothed SR (SRm) in EEG during interictal, preictal, and ictal periods is analyzed and employed as an index for seizure prediction. Experiments with long-term intracranial EEGs of 21 patients show that the proposed seizure prediction approach achieves a sensitivity of 75.8% with an average false prediction rate of 0.09/h. The low computational complexity of the proposed approach enables its possibility of applications in an implantable device for epilepsy therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sanei, S., & Chambers, J. A. (2007) · Wiley eBooks · doi:10.1002/9780470511923 · Cited by 1,552
Maragos, P. A., & Schafer, R. W. (1987) · IEEE Transactions on Acoustics Speech and Signal Processing · doi:10.1109/tassp.1987.1165259 · Cited by 739
Epileptic Seizures May Begin Hours in Advance of Clinical Onset
Litt, B., Esteller, R., Echauz, J., D'Alessandro, M., Shor, R., Henry, T., Pennell, P., Epstein, C., Bakay, R., Dichter, M., et al. (2001) · Neuron · doi:10.1016/s0896-6273(01)00262-8 · Cited by 641
Morphological filters--Part II: Their relations to median, order-statistic, and stack filters
Maragos, P., & Schafer, R. W. (1987) · IEEE Transactions on Acoustics Speech and Signal Processing · doi:10.1109/tassp.1987.1165254 · Cited by 581
Single-neuron dynamics in human focal epilepsy
Truccolo, W., Donoghue, J. A., Hochberg, L. R., Eskandar, E. N., Madsen, J. R., Anderson, W. S., Brown, E. N., Halgren, E., & Cash, S. S. (2011) · Nature Neuroscience · doi:10.1038/nn.2782 · Cited by 514
Phase space topography and the Lyapunov exponent of electrocorticograms in partial seizures
Iasemidis, L. D., Chris Sackellares, J., Zaveri, H. P., & Williams, W. J. (1990) · Brain Topography · doi:10.1007/bf01140588 · Cited by 472
Epileptic seizures are preceded by a decrease in synchronization
Mormann, F., Kreuz, T., Andrzejak, R. G., David, P., Lehnertz, K., & Elger, C. E. (2003) · Epilepsy Research · doi:10.1016/s0920-1211(03)00002-0 · Cited by 456
Epileptic seizures can be anticipated by non-linear analysis
Martinerie, J., Adam, C., Quyen, M. L. V., Baulac, M., Clemenceau, S., Renault, B., & Varela, F. J. (1998) · Nature Medicine · doi:10.1038/2667 · Cited by 417
Seizure prediction with spectral power of EEG using cost-sensitive support vector machines
Park, Y., Luo, L., Parhi, K. K., & Netoff, T. (2011) · Epilepsia · doi:10.1111/j.1528-1167.2011.03138.x · Cited by 398
A new interpretation of nonlinear energy operator and its efficacy in spike detection
Mukhopadhyay, S., & Ray, G. C. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.661266 · Cited by 385
Classification of patterns of EEG synchronization for seizure prediction
Mirowski, P., Madhavan, D., LeCun, Y., & Kuzniecky, R. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.09.002 · Cited by 380
Maiwald, T., Winterhalder, M., Aschenbrenner-Scheibe, R., Voss, H. U., Schulze-Bonhage, A., & Timmer, J. (2004) · Physica D: Nonlinear Phenomena · doi:10.1016/j.physd.2004.02.013 · Cited by 299
Morphological systems for multidimensional signal processing
Maragos, P., & Schafer, R. W. (1990) · Proceedings of the IEEE · doi:10.1109/5.54808 · Cited by 299
Spike detection: a review and comparison of algorithms
Wilson, S. B., & Emerson, R. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00297-3 · Cited by 294
Winterhalder, M., Maiwald, T., Voss, H. U., Aschenbrenner-Scheibe, R., Timmer, J., & Schulze-Bonhage, A. (2003) · Epilepsy & Behavior · doi:10.1016/s1525-5050(03)00105-7 · Cited by 237
A multistage system to detect epileptiform activity in the EEG
Dingle, A. A., Jones, R. D., Carroll, G. J., & Fright, W. R. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.250582 · Cited by 199
Long-term prospective on-line real-time seizure prediction
Iasemidis, L. D., Shiau, D.-S., Pardalos, P. M., Chaovalitwongse, W., Narayanan, K., Prasad, A., Tsakalis, K., Carney, P. R., & Sackellares, J. C. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.10.013 · Cited by 195
Iasemidis, L. D., Pardalos, P., Sackellares, J. C., & Shiau, D.-S. (2001) · Journal of Combinatorial Optimization · doi:10.1023/a:1009877331765 · Cited by 183
Indiradevi, K. P., Elias, E., Sathidevi, P. S., Dinesh Nayak, S., & Radhakrishnan, K. (2008) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2008.04.010 · Cited by 170
Temporo-spatial patterns of pre-ictal spike activity in human temporal lobe epilepsy
Lange, H., Lieb, J. P., Engel, J., & Crandall, P. H. (1983) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(83)90022-6 · Cited by 148
Matthias Winterhalder, A., Schelter, B. O., Maiwald, T., Brandt, A., Schad, A., Schulze‐Bonhage, A., & Timmer, J. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.07.312 · Cited by 98
Seizure anticipation in pediatric epilepsy: use of kolmogorov entropy
van Drongelen, W., Nayak, S., Frim, D. M., Kohrman, M. H., Towle, V. L., Lee, H. C., McGee, A. B., Chico, M., & Hecox, K. E. (2003) · Pediatric Neurology · doi:10.1016/s0887-8994(03)00145-0 · Cited by 93
Ko, C., & Chung, H. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00284-9 · Cited by 72
Clinical Electroencephalography
Lüders, H. O., Noachtar, S., & Rémi, J. (2024) · Oxford University Press eBooks · doi:10.1093/med/9780197502334.003.0003 · Cited by 52
Cited by
Truong, N. D., Nguyen, A. D., Kuhlmann, L., Bonyadi, M. R., Yang, J., Ippolito, S., & Kavehei, O. (2018) · Neural Networks · doi:10.1016/j.neunet.2018.04.018 · Cited by 635
Tsiouris, Κ. Μ., Pezoulas, V. C., Zervakis, M., Konitsiotis, S., Koutsouris, D. D., & Fotiadis, D. I. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.05.019 · Cited by 632
Seizure prediction – ready for a new era
Kuhlmann, L., Lehnertz, K., Richardson, M. P., Schelter, B., & Zaveri, H. P. (2018) · Nature Reviews Neurology · doi:10.1038/s41582-018-0055-2 · Cited by 450
A Multivariate Approach for Patient-Specific EEG Seizure Detection Using Empirical Wavelet Transform
Bhattacharyya, A., & Pachori, R. B. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2650259 · Cited by 419
Machine Learning for Predicting Epileptic Seizures Using EEG Signals: A Review
Rasheed, K., Qayyum, A., Qadir, J., Sivathamboo, S., Kwan, P., Kuhlmann, L., O'Brien, T., & Razi, A. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2020.3008792 · Cited by 409
Metadata
- Authors
- Li, S., Zhou, W., Yuan, Q., & Liu, Y.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2013-11
- Volume
- 21
- Issue
- 6
- Pages
- 880-886
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2025668297
- Cited by
- 170
- References
- 24
- FWCI
- 3.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.