Quantifying the Deep Tendon Reflex Using Varying Tendon Indentation Depths: Applications to Spasticity
The DOI matches its Crossref record; 52 of the 60 references it cites were found in a registry or an index.
Abstract
The deep tendon reflex (DTR) is often utilized to characterize the neuromuscular health of individuals because it is cheap, quick to implement, and requires limited equipment. However, DTR assessment is unreliable and assessor-dependent improve the reliability of the DTR assessment, we devised a novel standardization procedure. Our approach is based on the hypothesis that the neuromuscular state of a muscle changes systematically with respect to the indentation depth of its tendon. We tested the hypothesis by progressively indenting the biceps tendons on each side of nine hemiplegic stroke survivors to different depths, and then superimposing a series of brief controlled taps at each indentation depth to elicit a reflex response. Our results show that there exists a unique indentation depth at which reflex responses are consistently recorded (termed the Reflex Threshold) with increasing amplitude along increasing indentation depth. We further show that the reflex threshold depth is systematically smaller on the affected side of stroke survivors and that it is negatively correlated with the Modified Ashworth Score (VAF 70%). Our procedure also enables measurement of passive mechanical properties at the indentation location. In conclusion, our study shows that controlling for the indentation depth of the tendon of a muscle alters its reflex response predictably. Our novel device and method could be used to estimate neuromuscular changes in muscle (e.g., spasticity). Although some refinement is needed, this method opens the door to more reliable quantification of the DTR.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In addition, the DTR test is one of many methods that can be used to diagnose upper and lower motor neuronal disorders3).”
From Clinical availability of the deep tendon reflex test using a novel apparatus in healthy subjects (2015) · cites this paper as [3]
Citations
Cites
Interrater Reliability of a Modified Ashworth Scale of Muscle Spasticity
Bohannon, R. W., & Smith, M. B. (1987) · Physical Therapy · doi:10.1093/ptj/67.2.206 · Cited by 5,424
PRELIMINARY TRIAL OF CARISOPRODOL IN MULTIPLE SCLEROSIS.
Ashworth, B. (1964) · PubMed · Cited by 1,475
Pandyan, A. D., Johnson, G. R., Price, C. I. M., Curless, R. H., Barnes, M. P., & Rodgers, H. (1999) · Clinical Rehabilitation · doi:10.1191/026921599677595404 · Cited by 833
Sommerfeld, D. K., Eek, E. U.-B., Svensson, A.-K., Holmqvist, L. W., & von Arbin, M. H. (2004) · Stroke · doi:10.1161/01.str.0000105386.05173.5e · Cited by 724
Spastic hypertonia: mechanisms and measurement.
Katz, R. T., & Rymer, W. Z. (1989) · PubMed · Cited by 624
Self-citationPrevalence of spasticity post stroke
Watkins, C. L., Leathley, M. J., Gregson, J. M., Moore, A. P., Smith, T. L., & Sharma, A. K. (2002) · Clinical Rehabilitation · doi:10.1191/0269215502cr512oa · Cited by 496
Occurence and Clinical Predictors of Spasticity After Ischemic Stroke
Urban, P. P., Wolf, T., Uebele, M., Marx, J. J., Vogt, T., Stoeter, P., Bauermann, T., Weibrich, C., Vucurevic, G. D., Schneider, A., et al. (2010) · Stroke · doi:10.1161/strokeaha.110.581991 · Cited by 393
Identification of intrinsic and reflex contributions to human ankle stiffness dynamics
Kearney, R. E., Stein, R. B., & Parameswaran, L. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.581944 · Cited by 392
Spasticity-assessment: a review
Biering-Sørensen, F., Nielsen, J. B., & Klinge, K. (2006) · Spinal Cord · doi:10.1038/sj.sc.3101928 · Cited by 342
Crowe, A., & Matthews, P. B. C. (1964) · The Journal of Physiology · doi:10.1113/jphysiol.1964.sp007476 · Cited by 331
Mirbagheri, M. M., Barbeau, H., & Kearney, R. E. (2000) · Experimental Brain Research · doi:10.1007/s002210000534 · Cited by 300
Quantitative relations between hypertonia and stretch reflex threshold in spastic hemiparesis
Powers, R. K., Marder‐Meyer, J., & Rymer, W. Z. (1988) · Annals of Neurology · doi:10.1002/ana.410230203 · Cited by 218
Self-citationAutomatic tracking of medial gastrocnemius fascicle length during human locomotion
Cronin, N. J., Carty, C. P., Barrett, R. S., & Lichtwark, G. (2011) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00530.2011 · Cited by 213
Spasticity causes a fundamental rearrangement of muscle–joint interaction
Lieber, R. L., & Fridén, J. (2002) · Muscle & Nerve · doi:10.1002/mus.10036 · Cited by 209
Voerman, G., Gregorič, M., & Hermens, H. (2005) · Disability and Rehabilitation · doi:10.1080/09638280400014600 · Cited by 201
Quantitative measures of spasticity in post-stroke patients
Pisano, F., Miscio, G., Del Conte, C., Pianca, D., Candeloro, E., & Colombo, R. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00289-3 · Cited by 166
Stretch reflex dynamics in spastic elbow flexor muscles
Powers, R. K., Campbell, D. L., & Rymer, W. Z. (1989) · Annals of Neurology · doi:10.1002/ana.410250106 · Cited by 166
Self-citationMuscle spindle responses to stretch in normal and spastic subjects
Hagbarth, K.-E., Wallin, G., & Löfstedt, L. (2018) · Journal of Rehabilitation Medicine · doi:10.2340/1650197705156159 · Cited by 164
Application of Passive Stretch and Its Implications for Muscle Fibers
De Deyne, P. G. (2001) · Physical Therapy · doi:10.1093/ptj/81.2.819 · Cited by 159
Loram, I. D., Maganaris, C. N., & Lakie, M. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01229.2005 · Cited by 145
Lennerstrand, G. (1968) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1968.tb04106.x · Cited by 111
Herbert, R., Clarke, J., Kwah, L. K., Diong, J. H. L., Martin, J., Clarke, E., Bilston, L. E., & Gandevia, S. C. (2011) · The Journal of Physiology · doi:10.1113/jphysiol.2011.212175 · Cited by 108
Hoang, P. D., Herbert, R., Todd, G., Gorman, R. B., & Gandevia, S. C. (2007) · Journal of Experimental Biology · doi:10.1242/jeb.002204 · Cited by 101
Reliability of the NINDS Myotatic Reflex Scale
Litvan, I., Mangone, C. A., Werden, W., Bueri, J. A., Estol, C. J., Garcea, D. O., Rey, R. C., Sica, R. E. P., Hallett, M., & Bartko, J. J. (1996) · Neurology · doi:10.1212/wnl.47.4.969 · Cited by 92 · cited 1×
“Even though these scales have shown inconclusive intra- and inter-observer reliability ([11], [16], [17]) the tendon hammer is widely used in the clinic to assess spasticity because the test is quick to perform, requires minimal training, and involves virtually no equipment cost.”
BackgroundHallett, M. (1993) · Neurology · doi:10.1212/wnl.43.12.2723 · Cited by 86 · cited 1×
“Using either the Mayo Clinic scale for tendon reflex assessment or the National Institute of Neurological Disorders and Stroke (NINDS) myotatic reflex scale, a number is assigned to the intensity of the response [14], [15].”
Manschot, S., van Passel, L., Buskens, E., Algra, A., & van Gijn, J. (1998) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.64.2.253 · Cited by 86 · cited 1×
“Even though these scales have shown inconclusive intra- and inter-observer reliability ([11], [16], [17]) the tendon hammer is widely used in the clinic to assess spasticity because the test is quick to perform, requires minimal training, and involves virtually no equipment cost.”
BackgroundKong, K. H., Lee, J., & Chua, K. S. G. (2011) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2011.06.027 · Cited by 84
Faist, M., Ertel, M., Berger, W., & Dietz, V. (1999) · Brain · doi:10.1093/brain/122.3.567 · Cited by 80
Chung, S. G., van Rey, E. M., Bai, Z., Rymer, W. Z., Roth, E. J., & Zhang, L. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.09.051 · Cited by 73
Self-citationMirbagheri, M. M., Settle, K., Harvey, R. A., & Rymer, W. Z. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00049.2007 · Cited by 64
Self-citationBiceps femoris tendon jerk reflexes are enhanced at the end of the swing phase in humans
de Crommert, H. W. A. A. V., Faist, M., Berger, W., & Duysens, J. (1996) · Brain Research · doi:10.1016/0006-8993(96)00885-2 · Cited by 62
Tardieu, C., Tabary, J. C., Tabary, C., & TARDIEU, G. (1982) · PubMed · Cited by 61
A Comparison of Methods to Assess the Excitability of Lower Motoneurones
Milanov, I. G. (1992) · Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques · doi:10.1017/s0317167100042554 · Cited by 60
System identification of tendon reflex dynamics
Zhang, L.-Q., Huang, H., Sliwa, J. A., & Rymer, W. Z. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.769410 · Cited by 53 · cited 1×
“Third, the initial length of the muscle is often not well controlled by the examiner, even though it also affects the intensity of the reflex response [39], [40].”
BackgroundSelf-citationLennerstrand, G., & Thoden, U. (1968) · Acta Physiologica Scandinavica · doi:10.1111/j.1365-201x.1968.tb10897.x · Cited by 52
Pagliaro, P., & Zamparo, P. (1999) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(98)00045-5 · Cited by 47
Kinematic quantitation of the patellar tendon reflex using a tri-axial accelerometer
Mamizuka, N., Sakane, M., Kaneoka, K., Hori, N., & Ochiai, N. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.10.003 · Cited by 47
Reliability of the clinical and electromyographic examination of tendon reflexes
Stam, J., & Crevel, H. (1990) · Journal of Neurology · doi:10.1007/bf00314735 · Cited by 46 · cited 1×
“Even though these scales have shown inconclusive intra- and inter-observer reliability ([11], [16], [17]) the tendon hammer is widely used in the clinic to assess spasticity because the test is quick to perform, requires minimal training, and involves virtually no equipment cost.”
BackgroundAsakawa, D. S., Pappas, G. P., Blemker, S. S., DRACE, J. E., & Delp, S. L. (2003) · Seminars in Musculoskeletal Radiology · doi:10.1055/s-2004-815676 · Cited by 39
Lebiedowska, M. K., & Fisk, J. R. (2003) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(02)04946-8 · Cited by 37
A comparative study of methods for estimation of presynaptic inhibition
Milanov, I. G. (1992) · Journal of Neurology · doi:10.1007/bf00810355 · Cited by 36
QUANTIFIED DEEP TENDON REFLEX DEVICE FOR RESPONSE AND LATENCY, THIRD GENERATION
Lemoyne, R. C., COROIAN, C., Mastroianni, T., & Grundfest, W. S. (2008) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519408002772 · Cited by 36
Wireless accelerometer reflex quantification system characterizing response and latency
Lemoyne, R. C., Coroian, C., & Mastroianni, T. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333086 · Cited by 28
Clinical examinations in neurology
Bastron, J. A. (1963) · Saunders eBooks · Cited by 27
Evaluation of Spasticity in Adults
Decq, P., Filipetti, P., & Lefaucheur, J. (2004) · Operative Techniques in Neurosurgery · doi:10.1053/j.otns.2005.02.003 · Cited by 25
Monitoring of head injury by myotatic reflex evaluation
Cozens, J. A., Miller, S., Chambers, I. R., & Mendelow, A. D. (2000) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.68.5.581 · Cited by 24
An evaluation of passive properties of spastic muscles in hemiparetic stroke survivors
Chardon, M. K., Suresh, N. L., & Rymer, W. Z. (2010) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2010.5626155 · Cited by 17
Self-citationRoper, B. A. (1975) · HAND · doi:10.1016/0072-968x(75)90027-3 · Cited by 13
Excitatory synaptic potentials in spastic human motoneurons have a short rise‐time
Suresh, N. L., Ellis, M. D., Moore, J., Heckman, H. M., & Rymer, W. Z. (2005) · Muscle & Nerve · doi:10.1002/mus.20318 · Cited by 10
Self-citationLennerstrand, G., & Thoden, U. (1968) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1968.tb04211.x · Cited by 10
A new method for reflex threshold estimation in spastic muscles
Chardon, M., Suresh, N. L., & Rymer, W. Z. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333509 · Cited by 9
Self-citationClinical Examinations in Neurology
MCDOWELL, F. H. (1957) · Archives of Neurology And Psychiatry · doi:10.1001/archneurpsyc.1957.02330420062011 · Cited by 8
Research works printed but not linked: 13
- 1957, Hand reflex gun
- 1956, Machine for Testing Reflex Actions of Humans
- 1996, Apparatus for achilles tendon reflex testing
- 1955, Apparatus for testing and measuring human reflexes
- 1999, Method for testing reflexes using electrocardiograph
- 1954, Machine for Testing Reflex Actions of Humans
- 2010, Reflexometry and hormone function
- 1996, Reflex measuring device and method
- 1973, Reflex meter
- 1995, Quantitative neural percussion hammer
- 0, Reflex Hammer
- 2008, System and method for evaluating neuromuscular and joint properties
- lance, 1980, Symp Synopsis, 485
Cited by
Spinal Cord Stimulation for Spasticity: Historical Approaches, Current Status, and Future Directions
Nagel, S. J., Wilson, S., Johnson, M. D., Machado, A. G., Frizon, L. A., Chardon, M. K., Reddy, C. G., Gillies, G. T., & Howard, M. A. (2017) · Neuromodulation Technology at the Neural Interface · doi:10.1111/ner.12591 · Cited by 90
Self-citationContributions of motoneuron hyperexcitability to clinical spasticity in hemispheric stroke survivors
Hu, X., Suresh, N. L., Chardon, M. K., & Rymer, W. Z. (2014) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.11.005 · Cited by 19
Self-citationAfzal, T., Chardon, M. K., Rymer, W. Z., & Suresh, N. L. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0623-8 · Cited by 18
Self-citationCollection of the digital data from the neurological examination
Vitturi, B. K., Nerdal, P. T., & Maetzler, W. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-01659-2 · Cited by 8
A Smart Tendon Hammer System for Remote Neurological Examination
Meinhold, W., Yamakawa, Y., Honda, H., Mori, T., Izumi, S., & Ueda, J. (2021) · Frontiers in Robotics and AI · doi:10.3389/frobt.2021.618656 · Cited by 8
Metadata
- Authors
- Chardon, M. K., Rymer, W. Z., & Suresh, N. L.
- Affiliations
- Northwestern University (US)
- Shirley Ryan AbilityLab (US)
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2014-03
- Volume
- 22
- Issue
- 2
- Pages
- 280-289
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2098614977
- Cited by
- 17
- References
- 60
- Citations by year
- 2026: 1 · 2025: 2 · 2023: 1 · 2021: 2 · 2020: 1 · 2019: 3 · 2018: 1 · 2017: 1 · 2016: 1 · 2015: 3 · 2014: 1
- FWCI
- 1.30
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of Neurological Disorders and Stroke
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (R24HD050821)
- Topics
- Health Sciences › Medicine › Clinical Neurology › Botulinum Toxin and Related Neurological Disorders
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- deep tendon reflexes, reflex threshold, spasticity, stroke, hemiplegia, biceps tendon, neuromuscular assessment, Modified Ashworth Scale, passive mechanical properties, assessment standardization
- MeSH terms
- Aged, Data Interpretation, Statistical, Electromyography, Female, Humans, Functional Laterality, Male, Middle Aged, Muscle Spasticity, Neurologic Examination, Physical Stimulation, Reflex, Stretch, Tendons, Survivors, Muscle, Skeletal, Stroke
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.