CoChat

Deep Tendon Reflexes: A Study Of Quantitative Methods

Marshall, Garrett L., Little, James W. · 2002 · The Journal of Spinal Cord Medicine

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The deep tendon reflex (DTR) is routinely used by clinicians to evaluate the nervous system. Depressed and hyperactive DTRs suggest peripheral and central nervous system compromise, respectively. Limitations of DTRs are: qualitative nature of the assessments based upon subjective grading, and limited inter-rater reliability. This preliminary study was undertaken to quantify the tendon tap used by clinicians to elicit DTRs and the reflex response elicited. METHODS: Tendon taps were applied to a force transducer in hypo-, normo-, and hyperreflexic ranges by 2 clinicians, using 3 different tendon hammers (Babinski, Queen Square, and Taylor). Patellar DTRs, measured as joint angle excursion with an electrogoniometer, were compared in hyper- and normoreflexic individuals. RESULTS: Median peak tap force was 1 2.8, 38.0, and 85.2 Newtons (Nt), respectively, for eliciting hyper-, normo-, and hyporeflexic DTRs. Peak tap force was similar in the hyper- and normoreflexic ranges for all 3 hammers; in the hyporeflexic range, peak tap forces with the Taylor hammer were lower. A good distinguishing feature between hyper- and normoreflexic patellar DTRs was briskness, measured as the quotient of knee excursion divided by peak tendon tap force. Knee excursion is a non-linear patellar DTR response, when measured sitting. CONCLUSIONS: Peak tap forces used by clinicians fall into 3 ranges: 0-20 Nt for hyperreflexia, 21-50 Nt for normoreflexia, and >50 Nt for hyporeflexia. The Taylor hammer, with small mass and short handle, has a ceiling effect in the hyporeflexic range. We propose a systematic method for DTR testing.

Overview

Integrity signals

Registry

Crossref · 10.1080/10790268.2002.11753608

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 13 references

Cited by

See all 28

Metadata

Authors
Marshall, G. L., & Little, J. W.
Affiliations
University of Washington (US)
Corresponding author
Little, James W.
Venue
The Journal of Spinal Cord Medicine
Published
2002-07
Volume
25
Issue
2
Pages
94-99
ISSN
  • 1079-0268 (ISSN-L)
  • 2045-7723
OpenAlex
W2418580413
Cited by
28
References
13
Citations by year
2026: 2 · 2024: 2 · 2022: 3 · 2021: 7 · 2020: 1 · 2018: 1 · 2016: 1 · 2015: 2 · 2014: 1 · 2013: 2 · 2012: 1
FWCI
0.00
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Spinal Cord Medicine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Clinical Neurology › Peripheral Nerve Disorders
  • Life Sciences › Neuroscience › Neurology › Neurology and Historical Studies
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
Keywords
deep tendon reflexes, hyperreflexia, hyporeflexia, patellar reflex, electrogoniometry, force sensor, inter-rater reliability
MeSH terms
Central Nervous System Diseases, Evaluation Studies as Topic, Humans, Male, Middle Aged, Reaction Time, Reflex, Abnormal, Reflex, Stretch, Sensitivity and Specificity, Severity of Illness Index, Tendons, Time Factors, Reproducibility of Results, Observer Variation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Deep Tendon Reflexes: A Study Of Quantitative Methods. https://app.cochat.ai/papers/10.1080/10790268.2002.11753608
The paper
Marshall, G. L., & Little, J. W. (2002). Deep Tendon Reflexes: A Study Of Quantitative Methods. The Journal of Spinal Cord Medicine. https://doi.org/10.1080/10790268.2002.11753608

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.