The DOI matches its Crossref record; 42 of the 43 references it cites were found in a registry or an index.
FORCe: Fully Online and Automated Artifact Removal for Brain-Computer Interfacing
Open accessAbstract
A fully automated and online artifact removal method for the electroencephalogram (EEG) is developed for use in brain-computer interfacing (BCI). The method (FORCe) is based upon a novel combination of wavelet decomposition, independent component analysis, and thresholding. FORCe is able to operate on a small channel set during online EEG acquisition and does not require additional signals (e.g., electrooculogram signals). Evaluation of FORCe is performed offline on EEG recorded from 13 BCI particpants with cerebral palsy (CP) and online with three healthy participants. The method outperforms the state-of the-art automated artifact removal methods Lagged Auto-Mutual Information Clustering (LAMIC) and Fully Automated Statistical Thresholding for EEG artifact Rejection (FASTER), and is able to remove a wide range of artifact types including blink, electromyogram (EMG), and electrooculogram (EOG) artifacts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Applying the artifact removal algorithm FORCe [73] effectively eliminates this component (S1 Fig).”
From The Cybathlon BCI race: Successful longitudinal mutual learning with two tetraplegic users (2018) · cites this paper as [73]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
RETRACTED: Artifacts and noise removal in electrocardiograms using independent component analysis
Chawla, M. P. S., Verma, H., & Kumar, V. (2007) · International Journal of Cardiology · doi:10.1016/j.ijcard.2007.06.037 · Cited by 54
RetractedControlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing
Benjamini, Y., & Hochberg, Y. (1995) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1995.tb02031.x · Cited by 109,482
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371
Independent component analysis: algorithms and applications
Hyvärinen, A., & Erkki Oja, A. (2000) · Neural Networks · doi:10.1016/s0893-6080(00)00026-5 · Cited by 8,926
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Event-related EEG/MEG synchronization and desynchronization: basic principles
Pfurtscheller, G., & Lopes da Silva, F. H. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00141-8 · Cited by 7,328
A blind source separation technique using second-order statistics
Belouchrani, A., Abed‐Meraim, K., Cardoso, J.-F., & Moulines, É. (1997) · IEEE Transactions on Signal Processing · doi:10.1109/78.554307 · Cited by 2,774
Nunez, P. L., & Srinivasan, R. (2006) · doi:10.1093/acprof:oso/9780195050387.001.0001 · Cited by 2,531
Electric Fields of the Brain: The Neurophysics of EEG
Nunez, P. L., & Harth, E. M. (1982) · Physics Today · doi:10.1063/1.2915137 · Cited by 2,257
Electrophysiological signatures of resting state networks in the human brain
Mantini, D., Perrucci, M. G., Del Gratta, C., Romani, G. L., & Corbetta, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0700668104 · Cited by 1,938
FASTER: Fully Automated Statistical Thresholding for EEG artifact Rejection
Nolan, H., Whelan, R., & Reilly, R. B. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.07.015 · Cited by 1,080
Removal of ocular artifact from the EEG: a review
Croft, R. J., & Barry, R. J. (2000) · Neurophysiologie Clinique · doi:10.1016/s0987-7053(00)00055-1 · Cited by 751
EMG contamination of EEG: spectral and topographical characteristics
Goncharova, I. I., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00093-2 · Cited by 705
Statistical control of artifacts in dense array EEG/MEG studies
Junghöfer, M., Elbert, T. R., Tucker, D. M., & Rockstroh, B. S. (2000) · Psychophysiology · doi:10.1111/1469-8986.3740523 · Cited by 577
Patients with ALS can use sensorimotor rhythms to operate a brain-computer interface
Kübler, A., Nijboer, F., Mellinger, J., Vaughan, T. M., Pawelzik, H., Schalk, G., McFarland, D. J., Birbaumer, N., & Wolpaw, J. R. (2005) · Neurology · doi:10.1212/01.wnl.0000158616.43002.6d · Cited by 539
Removal of Movement Artifact From High-Density EEG Recorded During Walking and Running
Gwin, J. T., Gramann, K., Makeig, S., & Ferris, D. P. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00105.2010 · Cited by 484
EEG-based neuroprosthesis control: A step towards clinical practice
Müller-Putz, G. R., Scherer, R., Pfurtscheller, G., & Rupp, R. (2005) · Neuroscience Letters · doi:10.1016/j.neulet.2005.03.021 · Cited by 477
Self-citationA brain-computer interface for long-term independent home use
Sellers, E. W., Vaughan, T. M., & Wolpaw, J. R. (2010) · Amyotrophic Lateral Sclerosis · doi:10.3109/17482961003777470 · Cited by 400
Ocular artifacts in EEG and event-related potentials I: Scalp topography
Lins, O. G., Picton, T. W., Berg, P., & Scherg, M. (1993) · Brain Topography · doi:10.1007/bf01234127 · Cited by 324
Neuper, C., Müller, G. R., Kübler, A., Birbaumer, N., & Pfurtscheller, G. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00387-5 · Cited by 317
Visualization of significant ERD/ERS patterns in multichannel EEG and ECoG data
Graimann, B., Huggins, J. E., Levine, S. P., & Pfurtscheller, G. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(01)00697-6 · Cited by 302
Ward, L. M. (2001) · The MIT Press eBooks · doi:10.7551/mitpress/2525.001.0001 · Cited by 234
Autocalibration and recurrent adaptation: Towards a plug and play online ERD-BCI
Faller, J., Vidaurre, C., Solis-Escalante, T., Neuper, C., & Scherer, R. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2189584 · Cited by 180
Self-citationValidation of SOBI components from high-density EEG
Tang, A. C., Sutherland, M. T., & McKinney, C. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.11.027 · Cited by 173
Artifact and Recording Concepts in EEG
Tatum, W. O., Dworetzky, B. A., & Schomer, D. L. (2011) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0b013e31821c3c93 · Cited by 146
Kumar, P. S., Arumuganathan, R., Sivakumar, K., & Vimal, C. (2008) · Cited by 120
Halder, S., Bensch, M., Mellinger, J., Bogdan, M., Kübler, A., Birbaumer, N., & Rosenstiel, W. (2007) · Computational Intelligence and Neuroscience · doi:10.1155/2007/82069 · Cited by 117
Removal of EEG Noise and Artifact Using Blind Source Separation
Fitzgibbon, S. P., Powers, D. M. W., Pope, K. J., & Clark, C. R. (2007) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0b013e3180556926 · Cited by 104
On the control of brain-computer interfaces by users with cerebral palsy
Daly, I. P., Billinger, M., Laparra-Hernández, J., Fabio Aloise, A., García, M. L., Faller, J., Scherer, R., & Muller-Putz, G. R. (2013) · Clinical Neurophysiology · doi:10.1016/j.clinph.2013.02.118 · Cited by 102
Self-citationOn the Automated Removal of Artifacts Related to Head Movement From the EEG
Daly, I. P., Billinger, M., Scherer, R., & Muller-Putz, G. R. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2254724 · Cited by 77
Self-citationWhat does clean EEG look like?
Daly, I. P., Pichiorri, F., Faller, J., Kaiser, V., Kreilinger, A., Scherer, R., & Muller-Putz, G. R. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346834 · Cited by 71
Self-citationAutomated Artifact Removal From the Electroencephalogram
Daly, I. P., Nicolaou, N., Nasuto, S. J., & Warwick, K. (2013) · Clinical EEG and Neuroscience · doi:10.1177/1550059413476485 · Cited by 61
Self-citationNew combinatorial clustering methods
Podani, J. (1989) · Plant Ecology · doi:10.1007/bf00045513 · Cited by 46
Automatic Artefact Removal from Event-related Potentials via Clustering
Nicolaou, N., & Nasuto, S. J. (2007) · The Journal of VLSI Signal Processing Systems for Signal Image and Video Technology · doi:10.1007/s11265-006-0011-z · Cited by 42
New combinatorial clustering methods
Podani, J. (1989) · Springer eBooks · doi:10.1007/978-94-009-2432-1_5 · Cited by 42
Wavelets for biomedical signal processing
Akay, M., & Mello, C. (2002) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.1997.756888 · Cited by 33
On the Use of Games for Noninvasive EEG-Based Functional Brain Mapping
Scherer, R., Moitzi, G., Daly, I. P., & Muller-Putz, G. R. (2013) · IEEE Transactions on Computational Intelligence and AI in Games · doi:10.1109/tciaig.2013.2250287 · Cited by 32
Self-citationTalsma, D. (2007) · Psychophysiology · doi:10.1111/j.1469-8986.2007.00612.x · Cited by 24
Pokorny, C., Pichler, G., Erlbeck, H., Lesenfants, D., Habbal, D., Noirhomme, Q., Risetti, M., & Mattia, D. (2013) · Cited by 9
Brain-Computer Interfacing for Users with Cerebral Palsy, Challenges and Opportunities
Daly, I. P., Billinger, M., Scherer, R., & Muller-Putz, G. R. (2013) · Lecture notes in computer science · doi:10.1007/978-3-642-39188-0_67 · Cited by 6
Self-citationAutomatic artefact detection in a self-paced brain-computer interface system
Yong, X., Fatourechi, M., Ward, R. K., & Birch, G. E. (2011) · IEEE Pacific Rim Conference on Communications, Computers and Signal Processing (PACRIM) · doi:10.1109/pacrim.2011.6032927 · Cited by 3
Rapid Prototyping for BNCI Users with Cerebral Palsy
Daly, I. P., Fabio Aloise, A., Aricò, P., Belda, J., Billinger, M., Bolinger, E., Febo Cincotti, A., Hettich, D. T., Iosa, M., Laparra-Hernández, J., et al. (2020) · TUGraz OPEN Library (Graz University of Technology) · doi:10.3217/978-3-85125-260-6-27 · Cited by 3
Self-citation
Research works printed but not linked: 2
- ziehe, 1998, TDSEP?An efficient algorithm for blind source separation using time structure, Proc Int Conf Artificial Neural Networks, 675
- niedermeyer, 1999, The normal EEG of the waking adult, Electroencephalography Basic principles clinical application and related fields, 149
Cited by
Sorted by citations
Removal of Artifacts from EEG Signals: A Review
Xiao, J., Bian, G., & Tian, Z. (2019) · Sensors · doi:10.3390/s19050987 · Cited by 900
Methods for artifact detection and removal from scalp EEG: A review
Islam, M. K., Rastegarnia, A., & Yang, Z. Q. (2016) · Neurophysiologie Clinique · doi:10.1016/j.neucli.2016.07.002 · Cited by 457
A multimodal approach to estimating vigilance using EEG and forehead EOG
Zheng, W.-L., & Lu, B.-L. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa5a98 · Cited by 424
Hong, K.-S., & Khan, M. J. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00035 · Cited by 267
Identification and Removal of Physiological Artifacts From Electroencephalogram Signals: A Review
Mannan, M. M. N., Kamran, M. A., & Jeong, M. Y. (2018) · IEEE Access · doi:10.1109/access.2018.2842082 · Cited by 224
Metadata
- Authors
- Daly, I., Scherer, R., Billinger, M., & Muller-Putz, G.
- Affiliations
- Graz University of Technology (AT)
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2015-09
- Volume
- 23
- Issue
- 5
- Pages
- 725-736
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2005521760
- Cited by
- 174
- References
- 43
- Citations by year
- 2026: 1 · 2025: 10 · 2024: 9 · 2023: 14 · 2022: 12 · 2021: 17 · 2020: 21 · 2019: 25 · 2018: 24 · 2017: 18 · 2016: 15 · 2015: 7
- FWCI
- 7.61
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- Open Access at Essex (University of Essex) (acceptedVersion)
- Funders
- FP7 Framework EU Research Project ABC (287774)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Computer Science › Human-Computer Interaction › Gaze Tracking and Assistive Technology
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- EEG artifact removal, brain-computer interface, wavelet decomposition, independent component analysis, thresholding, blink artifacts, cerebral palsy
- MeSH terms
- Algorithms, Brain, Cerebral Palsy, Electroencephalography, Evoked Potentials, Female, Humans, Male, Online Systems, Pattern Recognition, Automated, Sensitivity and Specificity, Signal Processing, Computer-Assisted, Software, Reproducibility of Results, Artifacts, Internet, Principal Component Analysis, Wavelet Analysis, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review