Cited by 64Muscle activation and electromyography studiesNeuroscience and Neural EngineeringProsthetics and Rehabilitation Robotics

Closed-Loop Control of Myoelectric Prostheses With Electrotactile Feedback: Influence of Stimulation Artifact and Blanking

Hartmann, Cornelia, Dosen, Strahinja, Amsuess, Sebastian, Farina, Dario·2015·IEEE Transactions on Neural Systems and Rehabilitation Engineering

Abstract

Electrocutaneous stimulation is a promising approach to provide sensory feedback to amputees, and thus close the loop in upper limb prosthetic systems. However, the stimulation introduces artifacts in the recorded electromyographic (EMG) signals, which may be detrimental for the control of myoelectric prostheses. In this study, artifact blanking with three data segmentation approaches was investigated as a simple method to restore the performance of pattern recognition in prosthesis control (eight motions) when EMG signals are corrupted by stimulation artifacts. The methods were tested over a range of stimulation conditions and using four feature sets, comprising both time and frequency domain features. The results demonstrated that when stimulation artifacts were present, the classification performance improved with blanking in all tested conditions. In some cases, the classification performance with blanking was at the level of the benchmark (artifact-free data). The greatest pulse duration and frequency that allowed a full performance recovery were 400 μs and 150 Hz, respectively. These results show that artifact blanking can be used as a practical solution to eliminate the negative influence of the stimulation artifact on EMG pattern classification in a broad range of conditions, thus allowing to close the loop in myoelectric prostheses using electrotactile feedback.

Integrity signals

Registry

Crossref · 10.1109/tnsre.2014.2357175

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Selective sampling methods have been developed to overcome the long discontinuity in recorded data, which synchronise the ADC with stimulation artifacts.

    “To overcome the long discontinuity in recorded data, selective sampling methods have been developed, which synchronise the ADC with stimulation artifacts [192].”
  • A hybrid approach is often adopted that combines multiple structures for effective artifact detection and cancellation while adhering to the system power and area constraints.

    “A hybrid approach is often adopted that combines multiple structures for effective artifact detection and cancellation while adhering to the system power and area constraints [152], [192], [193].”
  • Digital processing techniques such as reconstruction of the biopotentials use interpolation methods that can be applied in parallel to signal blanking to fill in the blocking phases of the synchronised sample-and-hold process.

    “Digital processing techniques such as reconstruction of the biopotentials use interpolation methods that can be applied in parallel to signal blanking to fill in the blocking phases of the synchronised sample-and-hold process [192], [195].”

The citation lists haven’t been fetched yet

References 27 · Cited by 64

Authors
Hartmann, C., Dosen, S., Amsuess, S., & Farina, D.
Affiliations
Universitätsmedizin Göttingen (DE)
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2015-09
Volume
23
Issue
5
Pages
807-816
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2059074146
Cited by
64
References
27
Citations by year
2026: 2 · 2025: 6 · 2024: 6 · 2023: 6 · 2022: 5 · 2021: 5 · 2020: 7 · 2019: 4 · 2018: 5 · 2017: 8 · 2016: 7 · 2015: 2 · 2014: 1
FWCI
3.12
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
  • PubMed (publishedVersion)
  • GRO (submittedVersion)
Funders
People Programme (Marie Curie Actions) of the European Union's Seventh Framework Programme (286208)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
Keywords
myoelectric prosthesis, electrotactile feedback, stimulation artifacts, EMG signal classification, upper limb prosthesis control, feedback control, time and frequency domain features
MeSH terms
Adult, Algorithms, Electromyography, Electric Stimulation Therapy, Female, Humans, Male, Pattern Recognition, Automated, Sensitivity and Specificity, Signal Processing, Computer-Assisted, Touch, Reproducibility of Results, Artifacts, Muscle, Skeletal, Feedback, Sensory

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review