A Hybrid Brain–Computer Interface Based on the Fusion of P300 and SSVEP Scores
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
The present study proposes a hybrid brain-computer interface (BCI) with 64 selectable items based on the fusion of P300 and steady-state visually evoked potential (SSVEP) brain signals. With this approach, row/column (RC) P300 and two-step SSVEP paradigms were integrated to create two hybrid paradigms, which we denote as the double RC (DRC) and 4-D spellers. In each hybrid paradigm, the target is simultaneously detected based on both P300 and SSVEP potentials as measured by the electroencephalogram. We further proposed a maximum-probability estimation (MPE) fusion approach to combine the P300 and SSVEP on a score level and compared this approach to other approaches based on linear discriminant analysis, a naïve Bayes classifier, and support vector machines. The experimental results obtained from thirteen participants indicated that the 4-D hybrid paradigm outperformed the DRC paradigm and that the MPE fusion achieved higher accuracy compared with the other approaches. Importantly, 12 of the 13 participants, using the 4-D paradigm achieved an accuracy of over 90% and the average accuracy was 95.18%. These promising results suggest that the proposed hybrid BCI system could be used in the design of a high-performance BCI-based keyboard.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Steady-state visually evoked potentials: Focus on essential paradigms and future perspectives
Vialatte, F.-B., Maurice, M., Dauwels, J., & Cichocki, A. (2010) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2009.11.005 · Cited by 1,066 · cited 1×
“The SSVEP is a periodic visual cortical response evoked by certain repetitive stimuli with a constant frequency [5].”
BackgroundHow many people are able to control a P300-based brain-computer interface (BCI)?
Guger, C., Daban, S., Sellers, E., Holzner, C., Krausz, G., Carabalona, R., Gramatica, F., & Edlinger, G. (2009) · Neuroscience Letters · doi:10.1016/j.neulet.2009.06.045 · Cited by 652
Visual and Auditory Brain–Computer Interfaces
Gao, S., Wang, Y., Gao, X., & Hong, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2300164 · Cited by 449
A Hybrid BCI System Combining P300 and SSVEP and Its Application to Wheelchair Control
Li, Y., Pan, J., Wang, F., & Yu, Z. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2270283 · Cited by 421
BCI demographics: how many (and what kinds of) people can use an SSVEP BCI?
Allison, B., Luth, T., Valbuena, D., Teymourian, A., Volosyak, I., & Graser, A. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039495 · Cited by 344
Cited by
Enhancing Detection of SSVEPs for a High-Speed Brain Speller Using Task-Related Component Analysis
Nakanishi, M., Wang, Y., Chen, X., Wang, Y.-T., Gao, X., & Jung, T.-P. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2694818 · Cited by 813
Brain–Computer Interface Spellers: A Review
Rezeika, A., Benda, M., Stawicki, P., Gembler, F., Saboor, A., & Volosyak, I. (2018) · Brain Sciences · doi:10.3390/brainsci8040057 · Cited by 391
Progress in Brain Computer Interface: Challenges and Opportunities
Saha, S., Mamun, K. A., Ahmed, K., Mostafa, R., Naik, G. R., Darvishi, S., Khandoker, A. H., & Baumert, M. (2021) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2021.578875 · Cited by 365
A survey on deep learning-based non-invasive brain signals: recent advances and new frontiers
Zhang, X., Yao, L., Wang, X., Monaghan, J., McAlpine, D., & Zhang, Y. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abc902 · Cited by 296
Hong, K.-S., & Khan, M. J. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00035 · Cited by 267
Metadata
- Authors
- Yin, E., Zeyl, T., Saab, R., Chau, T., Hu, D., & Zhou, Z.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2015-07
- Volume
- 23
- Issue
- 4
- Pages
- 693-701
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2011823558
- Cited by
- 120
- References
- 6
- FWCI
- 7.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Hybrid Brain–Computer Interface Based on the Fusion of P300 and SSVEP Scores. https://app.cochat.ai/papers/10.1109/tnsre.2015.2403270
- The paper
- Yin, E., Zeyl, T., Saab, R., Chau, T., Hu, D., & Zhou, Z. (2015). A Hybrid Brain–Computer Interface Based on the Fusion of P300 and SSVEP Scores. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2015.2403270
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.