An Approach for the Cooperative Control of FES With a Powered Exoskeleton During Level Walking for Persons With Paraplegia
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This paper describes a hybrid system that combines a powered lower limb exoskeleton with functional electrical stimulation (FES) for gait restoration in persons with paraplegia. The general control structure consists of two control loops: a motor control loop, which utilizes joint angle feedback control to control the output of the joint motor to track the desired joint trajectories, and a muscle control loop, which utilizes joint torque profiles from previous steps to shape the muscle stimulation profile for the subsequent step in order to minimize the motor torque contribution required for joint angle trajectory tracking. The implementation described here incorporates stimulation of the hamstrings and quadriceps muscles, such that the hip joints are actuated by the combination of hip motors and the hamstrings, and the knee joints are actuated by the combination of knee motors and the quadriceps. In order to demonstrate efficacy, the control approach was implemented on three paraplegic subjects with motor complete spinal cord injuries ranging from levels T6 to T10. Experimental data indicates that the cooperative control system provided consistent and repeatable gait motions and reduced the torque and power output required from the hip and knee motors of the exoskeleton compared to walking without FES.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intention-based walking support for paraplegia patients with robot suit HAL
Suzuki, K., Mito, G., Kawamoto, H., Hasegawa, Y., & Sankai, Y. (2007) · Advanced Robotics · doi:10.1163/156855307781746061 · Cited by 474
Sit-to-stand and stand-to-sit transfer support for complete paraplegic patients with robot suit HAL
Tsukahara, A., Kawanishi, R., Hasegawa, Y., & Sankai, Y. (2010) · Advanced Robotics · doi:10.1163/016918610x512622 · Cited by 269
A Method for the Autonomous Control of Lower Limb Exoskeletons for Persons With Paraplegia
Quintero, H. A., Farris, R. J., & Goldfarb, M. (2012) · Journal of Medical Devices · doi:10.1115/1.4007181 · Cited by 97 · cited 5×
“in [38], each successive step is initiated by a shift in the location of the projection of the user's estimated center of pressure (CoP) along the ground in the sagittal plane, relative to the user's forward foot (i.”
BackgroundMethodInfluentialSelf-citation
Cited by
Hobbs, B., & Artemiadis, P. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00019 · Cited by 178
Esquenazi, A., Talaty, M., & Jayaraman, A. (2017) · PM&R · doi:10.1016/j.pmrj.2016.07.534 · Cited by 175
“Researchers at Vanderbilt also are investigating the potential of an assistive controller for individuals with lower extremity hemiparesis after a stroke, which in an experimental session was shown to improve measured gait outcomes in persons recovering from stroke [49].”
BackgroundClosed-loop functional optogenetic stimulation
Srinivasan, S. S., Maimon, B. E., Diaz, M., Song, H., & Herr, H. M. (2018) · Nature Communications · doi:10.1038/s41467-018-07721-w · Cited by 68
Dalla Gasperina, S., Ferrari, F., Gandolla, M., Pedrocchi, A., & Ambrosini, E. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3384939 · Cited by 18
Metadata
- Authors
- Ha, K. H., Murray, S. A., & Goldfarb, M.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2016-04
- Volume
- 24
- Issue
- 4
- Pages
- 455-466
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W1976199972
- Cited by
- 176
- References
- 3
- FWCI
- 8.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Approach for the Cooperative Control of FES With a Powered Exoskeleton During Level Walking for Persons With Paraplegia. https://app.cochat.ai/papers/10.1109/tnsre.2015.2421052
- The paper
- Ha, K. H., Murray, S. A., & Goldfarb, M. (2016). An Approach for the Cooperative Control of FES With a Powered Exoskeleton During Level Walking for Persons With Paraplegia. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2015.2421052
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.