CoChat

Switching EEG Headsets Made Easy: Reducing Offline Calibration Effort Using Active Weighted Adaptation Regularization

Open access
Wu, Dongrui, Lawhern, Vernon J., Hairston, W. David, Lance, Brent J. · 2016 · IEEE Transactions on Neural Systems and Rehabilitation Engineering

The DOI matches its Crossref record; 59 of the 61 references it cites were found in a registry or an index.

Abstract

Electroencephalography (EEG) headsets are the most commonly used sensing devices for brain-computer interface. In real-world applications, there are advantages to extrapolating data from one user session to another. However, these advantages are limited if the data arise from different hardware systems, which often vary between application spaces. Currently, this creates a need to recalibrate classifiers, which negatively affects people's interest in using such systems. In this paper, we employ active weighted adaptation regularization (AwAR), which integrates weighted adaptation regularization (wAR) and active learning, to expedite the calibration process. wAR makes use of labeled data from the previous headset and handles class-imbalance, and active learning selects the most informative samples from the new headset to label. Experiments on single-trial event-related potential classification show that AwAR can significantly increase the classification accuracy, given the same number of labeled samples from the new headset. In other words, AwAR can effectively reduce the number of labeled samples required from the new headset, given a desired classification accuracy, suggesting value in collating data for use in wide scale transfer-learning applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tnsre.2016.2544108

Cites

59 of 59 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 59 references

Research works printed but not linked: 4

  1. [39] W. Tu and S. Sun, 'Dynamical ensemble learning with model-friendly classifiers for domain adaptation,' in Proc. 21st Int'l. Conf. on Pattern Recognition (ICPR) , Tsukuba, Japan, November 2012. -
  2. [14] W. D. Hairston, K. W. Whitaker, A. J. Ries, J. M. Vettel, J. C. Bradford, S. E. Kerick, and K. McDowell, 'Usability of four commerciallyoriented EEG systems,' Journal of Neural Engineering , vol. 11, no. 4, 2014. -
  3. [42] US Department of the Army, 'Use of volunteers as subjects of research,' Government Printing Office , no. AR 70-25, 1990. -
  4. [41] US Department of Defense Office of the Secretary of Defense, 'Code of federal regulations protection of human subjects,' Government Printing Office , no. 32 CFR 19, 1999. -

Cited by

See all 74

Metadata

Authors
Wu, D., Lawhern, V. J., Hairston, W. D., & Lance, B. J.
Affiliations
DEVCOM Army Research Laboratory (US)
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2016-11
Volume
24
Issue
11
Pages
1125-1137
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2314733761
Cited by
74
References
61
Citations by year
2025: 4 · 2024: 5 · 2023: 7 · 2022: 8 · 2021: 13 · 2020: 14 · 2019: 11 · 2018: 4 · 2017: 3 · 2016: 5
FWCI
4.89
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
  • PubMed (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • arXiv (Cornell University)
Funders
U.S. Army Research Laboratory (W911NF-10-2-0022, W911NF-10-D-0002/TO 0023)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
  • Physical Sciences › Computer Science › Artificial Intelligence › Domain Adaptation and Few-Shot Learning
  • Physical Sciences › Computer Science › Human-Computer Interaction › Gaze Tracking and Assistive Technology
Keywords
EEG headset, active learning (machine learning), class imbalance, brain-computer interface, transfer learning, offline calibration
MeSH terms
Machine Learning, Algorithms, Electrodes, Electroencephalography, Equipment Design, Humans, Online Systems, Pattern Recognition, Automated, Sensitivity and Specificity, Reproducibility of Results, Equipment Failure Analysis, Brain-Computer Interfaces

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Switching EEG Headsets Made Easy: Reducing Offline Calibration Effort Using Active Weighted Adaptation Regularization. https://app.cochat.ai/papers/10.1109/tnsre.2016.2544108
The paper
Wu, D., Lawhern, V. J., Hairston, W. D., & Lance, B. J. (2016). Switching EEG Headsets Made Easy: Reducing Offline Calibration Effort Using Active Weighted Adaptation Regularization. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2016.2544108

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.