Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 83 of the 86 references it cites were found in a registry or an index, and 1 are not checked yet.

Riemannian Approaches in Brain-Computer Interfaces: A Review

Open access
Yger, Florian, Berar, Maxime, Lotte, Fabien · 2017 · IEEE Transactions on Neural Systems and Rehabilitation Engineering

Abstract

Although promising from numerous applications, current brain-computer interfaces (BCIs) still suffer from a number of limitations. In particular, they are sensitive to noise, outliers and the non-stationarity of electroencephalographic (EEG) signals, they require long calibration times and are not reliable. Thus, new approaches and tools, notably at the EEG signal processing and classification level, are necessary to address these limitations. Riemannian approaches, spearheaded by the use of covariance matrices, are such a very promising tool slowly adopted by a growing number of researchers. This article, after a quick introduction to Riemannian geometry and a presentation of the BCI-relevant manifolds, reviews how these approaches have been used for EEG-based BCI, in particular for feature representation and learning, classifier design and calibration time reduction. Finally, relevant challenges and promising research directions for EEG signal classification in BCIs are identified, such as feature tracking on manifold or multi-task learning.

Overview

Integrity signals

Registry

Crossref · 10.1109/tnsre.2016.2627016

Cites

83 of 84 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 86 references

Research works printed but not linked: 2

  1. chevallier, 2013, Metrics for multivariate dictionaries
  2. bartz, 2014, Covariance shrinkage for autocorrelated data, Proc NIPS, 1592

Cited by

See all 468

Metadata

Authors
Yger, F., Berar, M., & Lotte, F.
Affiliations
  • Lamsade (FR)
  • POTIOC: Nouvelles Interactions Multimodales pour une Expérience Utilisateur Stimulante (FR)
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2017-10
Volume
25
Issue
10
Pages
1753-1762
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2549437649
Cited by
420
References
86
Citations by year
2026: 49 · 2025: 52 · 2024: 47 · 2023: 58 · 2022: 65 · 2021: 45 · 2020: 55 · 2019: 29 · 2018: 13 · 2017: 6
FWCI
1.72
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
  • PubMed (publishedVersion)
  • HAL (submittedVersion, other-oa)
Funders
INRIA Project Lab BCI-LIFT and the French National Research Agency (ANR-15-CE23-0013-01)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
  • Physical Sciences › Computer Science › Artificial Intelligence › Emotion and Mood Recognition
  • Physical Sciences › Computer Science › Human-Computer Interaction › Gaze Tracking and Assistive Technology
Keywords
brain-computer interface, Riemannian geometry, EEG classification, covariance matrix, Riemannian manifolds, feature representation, classifier design, calibration time reduction, non-stationary EEG, feature tracking, multi-task learning
MeSH terms
Algorithms, Electroencephalography, Equipment Design, Humans, Models, Theoretical, Signal Processing, Computer-Assisted, Brain-Computer Interfaces

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Riemannian Approaches in Brain-Computer Interfaces: A Review. https://app.cochat.ai/papers/10.1109/tnsre.2016.2627016
The paper
Yger, F., Berar, M., & Lotte, F. (2017). Riemannian Approaches in Brain-Computer Interfaces: A Review. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2016.2627016

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.