Prospective Fall-Risk Prediction Models for Older Adults Based on Wearable Sensors
The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
Wearable sensors can provide quantitative, gait-based assessments that can translate to point-of-care environments. This investigation generated elderly fall-risk predictive models based on wearable-sensor-derived gait data and prospective fall occurrence, and identified the optimal sensor type, location, and combination for single and dual-task walking. 75 individuals who reported six month prospective fall occurrence (75.2 ± 6.6 years; 47 non-fallers and 28 fallers) walked 7.62 m under single-task and dual-task conditions while wearing pressure-sensinginsoles and tri-axial accelerometers at the head, pelvis, and left and right shanks. Fall-risk classificationmodels were assessed for all sensor combinations and three model types: neural network, naïve Bayesian, and support vector machine. The best performing model used a neural network, dual-task gait data, and input parameters from head, pelvis, and left shank accelerometers (accuracy = 57%, sensitivity = 43%, and specificity = 65%). The best single-sensor model used a neural network, dual-task gait data, and pelvis accelerometer parameters (accuracy = 54%, sensitivity = 35%, and specificity = 67%). Single-task and dual-task gait assessments provided similar fall-risk model performance. Fall-risk predictive models developed for point-of-care environments should use multi-sensor dual-task gait assessment with the pelvis location considered if assessment is limited to a single sensor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Risk Factors for Falls among Elderly Persons Living in the Community
Tinetti, M. E., Speechley, M., & Ginter, S. F. (1988) · New England Journal of Medicine · doi:10.1056/nejm198812293192604 · Cited by 6,509 · cited 2×
“THE incidence of falling starts to increase in middle age [1], reaching 30% of individuals older than 65 falling each year [2] and up to 42% for individuals older than 75 years [3], [4].”
BackgroundComparison of the predicted and observed secondary structure of T4 phage lysozyme
Matthews, B. W. (1975) · Biochimica et Biophysica Acta (BBA) - Protein Structure · doi:10.1016/0005-2795(75)90109-9 · Cited by 5,399 · cited 1×
“Model evaluation parameters included accuracy, specificity, sensitivity, positive predictive value (PPV), negative predictive value (NPV) [38], F1 score (harmonic mean of precision and sensitivity) [39], and Matthew’s Correlation Coefficient (MCC) [40].”
BackgroundAbe, S. (2001) · Springer eBooks · doi:10.1007/978-1-4471-0285-4 · Cited by 3,721
Interval Estimation for a Binomial Proportion
Brown, L. D., Cai, T. T., & DasGupta, A. (2001) · Statistical Science · doi:10.1214/ss/1009213286 · Cited by 3,538 · cited 1×
“Confidence intervals (CI) for model accuracy were computed using the Wilson interval (3), which is an appropriate binomial proportion interval estimation method for small sample sizes [42].”
MethodThe Activities-specific Balance Confidence (ABC) Scale
Powell, L. E., & Myers, A. M. (1995) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/50a.1.m28 · Cited by 2,869 · cited 1×
“Balance Confidence (ABC) [25] and Community Health Activities Model Program for Seniors (CHAMPS) [26] questionnaires.”
MethodPattern Classification (2nd ed.)
Duda, R. O., Hart, P. E., & Stork, D. G. (1999) · Cited by 2,520
The 6-minute walk: a new measure of exercise capacity in patients with chronic heart failure.
Guyatt, G. H., Sullivan, M. J., Thompson, P. J., Fallen, E. L., Pugsley, S. O., Taylor, D. W., & Berman, L. (1985) · Europe PMC (PubMed Central) · Cited by 2,439
Fear of falling: measurement strategy, prevalence, risk factors and consequences among older persons
Scheffer, A. C., Schuurmans, M. J., van Dijk, N., van der Hooft, T., & de Rooij, S. E. (2008) · Age and Ageing · doi:10.1093/ageing/afm169 · Cited by 1,451
The biomechanics and motor control of human gait : normal, elderly and pathological
Winter, D. A. (1991) · University of Waterloo Press eBooks · Cited by 1,428
Symmetry and limb dominance in able-bodied gait: a review
Sadeghi, H., Allard, P., Prince, F., & Labelle, H. (2000) · Gait & Posture · doi:10.1016/s0966-6362(00)00070-9 · Cited by 1,299 · cited 1×
“Plantar-pressure derived parameters were: • Temporal: Cadence, stride time, stance time, swing time, percent stance time, percent double support time, stride time symmetry index [29] between the left and right limbs, and coefficient of variation (CoV) for stride time, stance time, and swing time.”
Background
Cited by
Qiu, S., Zhao, H., Jiang, N., Wang, Z., Liu, L., An, Y., Zhao, H., Miao, X., Liu, R., & Fortino, G. (2022) · Information Fusion · doi:10.1016/j.inffus.2021.11.006 · Cited by 671
Anomaly Detection Based on Convolutional Recurrent Autoencoder for IoT Time Series
Yin, C., Zhang, S., Wang, J., & Xiong, N. N. (2022) · IEEE Transactions on Systems, Man, and Cybernetics: Systems · doi:10.1109/tsmc.2020.2968516 · Cited by 413
The potential of artificial intelligence to improve patient safety: a scoping review
Bates, D. W., Levine, D., Syrowatka, A., Kuznetsova, M., Craig, K. J. T., Rui, A., Jackson, G. P., & Rhee, K. (2021) · npj Digital Medicine · doi:10.1038/s41746-021-00423-6 · Cited by 323
Research of Fall Detection and Fall Prevention Technologies: A Systematic Review
Ren, L., & Peng, Y. (2019) · IEEE Access · doi:10.1109/access.2019.2922708 · Cited by 266
Hillel, I., Gazit, E., Nieuwboer, A., Avanzino, L., Rochester, L., Cereatti, A., Croce, U. D., Rikkert, M. O., Bloem, B. R., Pelosin, E., et al. (2019) · European Review of Aging and Physical Activity · doi:10.1186/s11556-019-0214-5 · Cited by 228
Wearable-Sensor-Based Detection and Prediction of Freezing of Gait in Parkinson’s Disease: A Review
Pardoel, S., Kofman, J., Nantel, J., & Lemaire, E. D. (2019) · Sensors · doi:10.3390/s19235141 · Cited by 201
Self-citationFall Prediction and Prevention Systems: Recent Trends, Challenges, and Future Research Directions
Rajagopalan, R., Litvan, I., & Jung, T.-P. (2017) · Sensors · doi:10.3390/s17112509 · Cited by 174
“Howcroft et al. [21] presented a comprehensive analysis of fall-risk prediction using two types of wearable sensors (accelerometers, pressure-sensing insoles), four accelerometer locations (head, pelvis, left and right shank), and three types of models (neural network, support vector machine, naïve…”
BackgroundFall detection and fall risk assessment in older person using wearable sensors: A systematic review
Bet, P., Castro, P. C., & Ponti, M. A. (2019) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2019.08.006 · Cited by 172
Metadata
- Authors
- Howcroft, J., Kofman, J., & Lemaire, E. D.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2017-10
- Volume
- 25
- Issue
- 10
- Pages
- 1812-1820
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2597642773
- Cited by
- 168
- References
- 43
- FWCI
- 29.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.