Real-Time Epileptic Seizure Detection Using EEG
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
This paper proposes a novel patient-specific real-time automatic epileptic seizure onset detection, using both scalp and intracranial electroencephalogram (EEG). The proposed technique obtains harmonic multiresolution and self-similarity-based fractal features from EEG for robust seizure onset detection. A fast wavelet decomposition method, known as harmonic wavelet packet transform (HWPT), is computed based on Fourier transform to achieve higher frequency resolutions without recursive calculations. Similarly, fractal dimension (FD) estimates are obtained to capture self-similar repetitive patterns in the EEG signal. Both FD and HWPT energy features across all EEG channels at each epoch are organized following the spatial information due to electrode placement on the skull. The final feature vector combines feature configurations of each epoch within the specified moving window to reflect the temporal information of EEG. Finally, relevance vector machine is used to classify the feature vectors due to its efficiency in classifying sparse, yet high-dimensional data sets. The algorithm is evaluated using two publicly available long-term scalp EEG (data set A) and short-term intracranial and scalp EEG (data set B) databases. The proposed algorithm is effective in seizure onset detection with 96% sensitivity, 0.1 per hour median false detection rate, and 1.89 s average detection latency, respectively. Results obtained from analyzing the short-term data offer 99.8% classification accuracy. These results demonstrate that the proposed method is effective with both short- and long-term EEG signal analyzes recorded with either scalp or intracranial modes, respectively. Finally, the use of less computationally intensive feature extraction techniques enables faster seizure onset detection when compared with similar techniques in the literature, indicating potential usage in real-time applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Tutorial on Support Vector Machines for Pattern Recognition
Burges, C. J. C. (1998) · Data Mining and Knowledge Discovery · doi:10.1023/a:1009715923555 · Cited by 16,429 · cited 1×
“In machine learning, Relevance Vector Machine (RVM) is a supervised learning method closely related to the Support Vector Machine (SVM) [33].”
MethodGoldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Bayesian Learning for Neural Networks
Neal, R. M. (1996) · Lecture Notes in Statistics · doi:10.1007/978-1-4612-0745-0 · Cited by 4,276 · cited 1×
“However, unlike SVM, RVM produces probabilistic outputs based on Bayesian inference techniques [34], [35].”
MethodAndrzejak, R. G., Lehnertz, K., Mormann, F., Rieke, C., David, P., & Elger, C. E. (2001) · Physical Review E · doi:10.1103/physreve.64.061907 · Cited by 3,032
Approach to an irregular time series on the basis of the fractal theory
Higuchi, T. (1988) · Physica D: Nonlinear Phenomena · doi:10.1016/0167-2789(88)90081-4 · Cited by 2,160 · cited 2×
“performed a comparison of FD estimation algorithms such as Katz’s [17], Higuchi’s [15], and K-nearest neighbor [18] for”
MethodMultifractality in human heartbeat dynamics
Ivanov, P. C., Amaral, L. A. N., Goldberger, A. L., Havlin, S., Rosenblum, M. G., Struzik, Z. R., & Stanley, H. E. (1999) · Nature · doi:10.1038/20924 · Cited by 1,456 · cited 1×
“Fractal dimension has been used in time series analysis of signal complexity in physiological signals [11]–[14].”
MethodMultifractality in Human Heartbeat Dynamics.
Ivanov, P. C., Amaral, L. A. N., Goldberger, A. L., Havlin, S., Rosenblum, M. G., Struzik, Z. R., & Stanley, E. (1999) · Centrum Wiskunde & Informatica (CWI), the national research institute for mathematics and computer science in the Netherlands · Cited by 1,327
Fractals and the analysis of waveforms
Katz, M. J. (1988) · Computers in Biology and Medicine · doi:10.1016/0010-4825(88)90041-8 · Cited by 826 · cited 1×
“performed a comparison of FD estimation algorithms such as Katz’s [17], Higuchi’s [15], and K-nearest neighbor [18] for”
MethodUnderstanding Nonlinear Dynamics
Kaplan, D., Glass, L., & Berger, S. A. (1996) · Physics Today · doi:10.1063/1.2807512 · Cited by 675
Automatic recognition of epileptic seizures in the EEG
Gotman, J. (1982) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(82)90038-4 · Cited by 674 · cited 3×
“In this work, the scalp EEG data is filtered using a bandpass filter between 3 Hz and 32 Hz since most seizure activity at ictal state occurs within this frequency range [4], [6].”
BackgroundMethod
Cited by
A review of feature extraction and performance evaluation in epileptic seizure detection using EEG
Boonyakitanont, P., Lek-uthai, A., Chomtho, K., & Songsiri, J. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.101702 · Cited by 390
Edge Computing for Smart Health: Context-Aware Approaches, Opportunities, and Challenges
Abdellatif, A. A., Mohamed, A., Chiasserini, C. F., Tlili, M., & Erbad, A. (2019) · IEEE Network · doi:10.1109/mnet.2019.1800083 · Cited by 272
A Multi-View Deep Learning Framework for EEG Seizure Detection
Yuan, Y., Xun, G., Jia, K., & Zhang, A. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2018.2871678 · Cited by 258
Metadata
- Authors
- Vidyaratne, L. S., & Iftekharuddin, K. M.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2017-11
- Volume
- 25
- Issue
- 11
- Pages
- 2146-2156
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2608948620
- Cited by
- 251
- References
- 42
- FWCI
- 10.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.