Real-Time Epileptic Seizure Detection Using EEG
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
This paper proposes a novel patient-specific real-time automatic epileptic seizure onset detection, using both scalp and intracranial electroencephalogram (EEG). The proposed technique obtains harmonic multiresolution and self-similarity-based fractal features from EEG for robust seizure onset detection. A fast wavelet decomposition method, known as harmonic wavelet packet transform (HWPT), is computed based on Fourier transform to achieve higher frequency resolutions without recursive calculations. Similarly, fractal dimension (FD) estimates are obtained to capture self-similar repetitive patterns in the EEG signal. Both FD and HWPT energy features across all EEG channels at each epoch are organized following the spatial information due to electrode placement on the skull. The final feature vector combines feature configurations of each epoch within the specified moving window to reflect the temporal information of EEG. Finally, relevance vector machine is used to classify the feature vectors due to its efficiency in classifying sparse, yet high-dimensional data sets. The algorithm is evaluated using two publicly available long-term scalp EEG (data set A) and short-term intracranial and scalp EEG (data set B) databases. The proposed algorithm is effective in seizure onset detection with 96% sensitivity, 0.1 per hour median false detection rate, and 1.89 s average detection latency, respectively. Results obtained from analyzing the short-term data offer 99.8% classification accuracy. These results demonstrate that the proposed method is effective with both short- and long-term EEG signal analyzes recorded with either scalp or intracranial modes, respectively. Finally, the use of less computationally intensive feature extraction techniques enables faster seizure onset detection when compared with similar techniques in the literature, indicating potential usage in real-time applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Tutorial on Support Vector Machines for Pattern Recognition
Burges, C. J. C. (1998) · Data Mining and Knowledge Discovery · doi:10.1023/a:1009715923555 · Cited by 16,429 · cited 1×
“In machine learning, Relevance Vector Machine (RVM) is a supervised learning method closely related to the Support Vector Machine (SVM) [33].”
MethodGoldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Bayesian Learning for Neural Networks
Neal, R. M. (1996) · Lecture Notes in Statistics · doi:10.1007/978-1-4612-0745-0 · Cited by 4,276 · cited 1×
“However, unlike SVM, RVM produces probabilistic outputs based on Bayesian inference techniques [34], [35].”
MethodAndrzejak, R. G., Lehnertz, K., Mormann, F., Rieke, C., David, P., & Elger, C. E. (2001) · Physical Review E · doi:10.1103/physreve.64.061907 · Cited by 3,032
Approach to an irregular time series on the basis of the fractal theory
Higuchi, T. (1988) · Physica D: Nonlinear Phenomena · doi:10.1016/0167-2789(88)90081-4 · Cited by 2,160 · cited 2×
“performed a comparison of FD estimation algorithms such as Katz’s [17], Higuchi’s [15], and K-nearest neighbor [18] for”
MethodMultifractality in human heartbeat dynamics
Ivanov, P. C., Amaral, L. A. N., Goldberger, A. L., Havlin, S., Rosenblum, M. G., Struzik, Z. R., & Stanley, H. E. (1999) · Nature · doi:10.1038/20924 · Cited by 1,456 · cited 1×
“Fractal dimension has been used in time series analysis of signal complexity in physiological signals [11]–[14].”
MethodMultifractality in Human Heartbeat Dynamics.
Ivanov, P. C., Amaral, L. A. N., Goldberger, A. L., Havlin, S., Rosenblum, M. G., Struzik, Z. R., & Stanley, E. (1999) · Centrum Wiskunde & Informatica (CWI), the national research institute for mathematics and computer science in the Netherlands · Cited by 1,327
Fractals and the analysis of waveforms
Katz, M. J. (1988) · Computers in Biology and Medicine · doi:10.1016/0010-4825(88)90041-8 · Cited by 826 · cited 1×
“performed a comparison of FD estimation algorithms such as Katz’s [17], Higuchi’s [15], and K-nearest neighbor [18] for”
MethodUnderstanding Nonlinear Dynamics
Kaplan, D., Glass, L., & Berger, S. A. (1996) · Physics Today · doi:10.1063/1.2807512 · Cited by 675
Automatic recognition of epileptic seizures in the EEG
Gotman, J. (1982) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(82)90038-4 · Cited by 674 · cited 3×
“In this work, the scalp EEG data is filtered using a bandpass filter between 3 Hz and 32 Hz since most seizure activity at ictal state occurs within this frequency range [4], [6].”
BackgroundMethodAutomated diagnosis of epileptic EEG using entropies
Acharya, U. R., Molinari, F., Sree, S. V., Chattopadhyay, S., Ng, K.-H., & Suri, J. S. (2012) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2011.07.007 · Cited by 626 · cited 1×
“[26] have”
Fractal characterization of complexity in temporal physiological signals
Eke, A., Herman, P., Kocsis, L., & Kozak, L. R. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/1/201 · Cited by 623
Understanding Nonlinear Dynamics
Kaplan, D., & Glass, L. (1995) · Texts in Applied Mathematics · doi:10.1007/978-1-4612-0823-5 · Cited by 581
A fast algorithm to determine fractal dimensions by box counting
Liebovitch, L. S., & Toth, T. (1989) · Physics Letters A · doi:10.1016/0375-9601(89)90854-2 · Cited by 514 · cited 2×
“Section II discusses feature extraction algorithms such as FD computation with box counting [27], and harmonic wavelet packet decomposition methods.”
MethodApplication of Machine Learning To Epileptic Seizure Detection
Shoeb, A. H., & Guttag, J. V. (2010) · Cited by 503
Automatic Seizure Detection Based on Time-Frequency Analysis and Artificial Neural Networks
Tzallas, A. T., Tsipouras, M. G., & Fotiadis, D. I. (2007) · Computational Intelligence and Neuroscience · doi:10.1155/2007/80510 · Cited by 473
Use of the fractal dimension for the analysis of electroencephalographic time series
Affinito, M., Carrozzi, M., Accardo, A., & Bouquet, F. (1997) · Biological Cybernetics · doi:10.1007/s004220050394 · Cited by 426 · cited 1×
“[12] have studied the ability of fractal dimension (FD) to characterize EEG recordings corresponding to different physiopathological conditions.”
BackgroundSamiee, K., Kovacs, P., & Gabbouj, M. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2360101 · Cited by 411 · cited 2×
“[44] formulate six different classification tasks: 1) Classification of E from a combination of E and A.”
MethodGuo, L., Rivero, D., & Pazos, A. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.08.030 · Cited by 399
Patient-specific seizure onset detection
Shoeb, A., Edwards, H., Connolly, J., Bourgeois, B., Ted Treves, S., & Guttag, J. (2004) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2004.05.005 · Cited by 312 · cited 1×
“The RVM is trained with seizure feature vectors derived from the first 20 s of seizure events recorded from the patient under evaluation [40] so that the seizure onset is accurately characterized.”
MethodNetwork dynamics of the brain and influence of the epileptic seizure onset zone
Burns, S. P., Santaniello, S., Yaffe, R. B., Jouny, C. C., Crone, N. E., Bergey, G. K., Anderson, W. S., & Sarma, S. V. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1401752111 · Cited by 294
Epileptic EEG classification based on extreme learning machine and nonlinear features
Yuan, Q., Zhou, W., Li, S., & Cai, D. (2011) · Epilepsy Research · doi:10.1016/j.eplepsyres.2011.04.013 · Cited by 286 · cited 1×
“[21] have presented an EEG classification using extreme learning machine and non-linear features [22] with an overall 96.”
MethodA system to detect the onset of epileptic seizures in scalp EEG
Saab, M. E., & Gotman, J. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.08.004 · Cited by 280 · cited 6×
“This may help to determine relevant effects of the seizure such as severity, and locating the affected region of the brain [4].”
BackgroundMethodInfluentialNewland, D. E. (1993) · Proceedings of the Royal Society of London. Series A: Mathematical and Physical Sciences · doi:10.1098/rspa.1993.0140 · Cited by 273 · cited 2×
“Harmonic wavelet transform, on the other hand, uses the harmonic basis function [31].”
Methodvan Mierlo, P., Papadopoulou, M., Carrette, E., Boon, P., Vandenberghe, S., Vonck, K., & Marinazzo, D. (2014) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2014.06.004 · Cited by 265 · cited 2×
“[19] discusses”
Song, Y., Crowcroft, J., & Zhang, J. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.07.003 · Cited by 252
Morphological Patterns of Seizures Recorded Intracranially
Spencer, S. S., Guimaraes, P., Katz, A., Kim, J., & Spencer, D. (1992) · Epilepsia · doi:10.1111/j.1528-1157.1992.tb01706.x · Cited by 230 · cited 1×
“Most epileptic seizures are associated with oscillatory patterns [4], [6], [37].”
BackgroundZandi, A. S., Javidan, M., Dumont, G. A., & Tafreshi, R. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2046417 · Cited by 228 · cited 5×
“EPILEPSY is one of the most common neurological disorders affecting approximately ∼70 million people around the world [1], [2].”
BackgroundInfluentialOptimal classification of epileptic seizures in EEG using wavelet analysis and genetic algorithm
Ocak, H. (2008) · Signal Processing · doi:10.1016/j.sigpro.2008.01.026 · Cited by 179
Automated seizure detection using a self-organizing neural network
Gabor, A. J., Leach, R. R., & Dowla, F. (1996) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(96)96001-0 · Cited by 166 · cited 2×
“71 h−1 [6], [7].”
BackgroundFergus, P., Hignett, D., Hussain, A., Al-Jumeily, D., & Abdel-Aziz, K. (2015) · BioMed Research International · doi:10.1155/2015/986736 · Cited by 159
Physiology of functional and effective networks in epilepsy
Yaffe, R. B., Borger, P., Mégevand, P., Groppe, D. M., Kramer, M., Chu, C. J., Santaniello, S., Meisel, C., Mehta, A. D., & Sarma, S. V. (2014) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.09.009 · Cited by 149 · cited 4×
“[2].”
BackgroundInfluentialModeling the Stationarity and Gaussianity of Spontaneous Electroencephalographic Activity
McEwen, J. A., & Anderson, G. B. (1975) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1975.324504 · Cited by 147 · cited 1×
“Consequently, an epoch window length of 2 s is considered in this study as this represents the minimum stationary interval for EEG [38].”
MethodFractals and the analysis of growth paths
Katz, M. J., & George, E. B. (1985) · Bulletin of Mathematical Biology · doi:10.1007/bf02460036 · Cited by 115 · cited 2×
“Fractal dimension has been used in time series analysis of signal complexity in physiological signals [11]–[14].”
BackgroundMethodAn efficient approach to machine health diagnosis based on harmonic wavelet packet transform
Yan, R., & Gao, R. X. (2005) · Robotics and Computer-Integrated Manufacturing · doi:10.1016/j.rcim.2004.10.005 · Cited by 108 · cited 7×
“where m and n are wavelet scaling parameters and take real values [30].”
BackgroundMethodInfluentialHopfengärtner, R., Kasper, B. S., Graf, W., Gollwitzer, S., Kreiselmeyer, G., Stefan, H., & Hamer, H. M. (2014) · Clinical Neurophysiology · doi:10.1016/j.clinph.2013.12.104 · Cited by 92 · cited 1×
“Similarly, other typical timefrequency analysis methods such as short-time Fourier transform are also used for seizure detection [10].”
MethodAutomated seizure onset detection for accurate onset time determination in intracranial EEG
Chan, A. M., Sun, F. T., Boto, E. H., & Wingeier, B. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.08.025 · Cited by 75 · cited 1×
“[39] for seizure onset detection using offline intracranial EEG.”
MethodFractal dimension characterizes seizure onset in epileptic patients
Esteller, R., Vachtsevanos, G., Echauz, J., Henry, T. R., Pennell, P. B., Epstein, C. M., Bakay, R. A. E., Bowen, C., & Litt, B. (1999) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.1999.758408 · Cited by 73 · cited 2×
“Several studies [16], [28] have shown that seizure activity alters self-similarity characteristics in EEG, establishing fractal estimations as a probable feature in seizure detection.”
BackgroundMethodQuickest detection of drug-resistant seizures: An optimal control approach
Santaniello, S., Burns, S. P., Golby, A. J., Singer, J. M., Anderson, W. S., & Sarma, S. V. (2011) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2011.08.041 · Cited by 58 · cited 1×
“[25] propose a ‘dynamic’ seizure detector that utilizes sequential hidden Markov model estimations of the singular value in”
BackgroundImproving early seizure detection
Jouny, C. C., Franaszczuk, P. J., & Bergey, G. K. (2011) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2011.08.029 · Cited by 46 · cited 2×
“As the goal of this study is to detect the onset of seizures, the detection latency is critical [5].”
BackgroundA few thoughts on “What is a seizure?”
Gotman, J. (2011) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2011.08.025 · Cited by 36 · cited 1×
“These seizures are commonly defined as sudden disturbances in brain function that indicate clinical signs of excessive and hyper-synchronous activity of neurons in the brain [2], [3].”
BackgroundHarmonic wavelet joint transform correlator: analysis, algorithm, and application to image denoising
Iftekharuddin, K. M. (2002) · Optical Engineering · doi:10.1117/1.1519245 · Cited by 6 · cited 1×
“The design of harmonic wavelets is based on the idea that its frequency spectrum is restricted to non-overlapping octave bands [32].”
BackgroundSelf-citation
Cited by
A review of feature extraction and performance evaluation in epileptic seizure detection using EEG
Boonyakitanont, P., Lek-uthai, A., Chomtho, K., & Songsiri, J. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.101702 · Cited by 390
Edge Computing for Smart Health: Context-Aware Approaches, Opportunities, and Challenges
Abdellatif, A. A., Mohamed, A., Chiasserini, C. F., Tlili, M., & Erbad, A. (2019) · IEEE Network · doi:10.1109/mnet.2019.1800083 · Cited by 272
A Multi-View Deep Learning Framework for EEG Seizure Detection
Yuan, Y., Xun, G., Jia, K., & Zhang, A. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2018.2871678 · Cited by 258
Metadata
- Authors
- Vidyaratne, L. S., & Iftekharuddin, K. M.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2017-11
- Volume
- 25
- Issue
- 11
- Pages
- 2146-2156
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2608948620
- Cited by
- 251
- References
- 42
- FWCI
- 10.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.