Toward Drowsiness Detection Using Non-hair-Bearing EEG-Based Brain-Computer Interfaces
The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
Drowsy driving is one of the major causes that lead to fatal accidents worldwide. For the past two decades, many studies have explored the feasibility and practicality of drowsiness detection using electroencephalogram (EEG)-based brain-computer interface (BCI) systems. However, on the pathway of transitioning laboratory-oriented BCI into real-world environments, one chief challenge is to obtain high-quality EEG with convenience and long-term wearing comfort. Recently, acquiring EEG from non-hair-bearing (NHB) scalp areas has been proposed as an alternative solution to avoid many of the technical limitations resulted from the interference of hair between electrodes and the skin. Furthermore, our pilot study has shown that informative drowsiness-related EEG features are accessible from the NHB areas. This study extends the previous work to quantitatively evaluate the performance of drowsiness detection using cross-session validation with widely studied machine-learning classifiers. The offline results showed no significant difference between the accuracy of drowsiness detection using the NHB EEG and the whole-scalp EEG across all subjects ( ). The findings of this study demonstrate the efficacy and practicality of the NHB EEG for drowsiness detection and could catalyze explorations and developments of many other real-world BCI applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LIBSVM: A library for support vector machines
Chang, C.-C., & Lin, C.-J. (2011) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/1961189.1961199 · Cited by 40,918 · cited 1×
“In this study, we used LIBSVM [34] with a linear kernel and grid-search optimization on 5-fold cross validation.”
MethodSelf-citationDelorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371 · cited 1×
“The data were then cleaned by the procedure of artifact subspace reconstruction (ASR) [24] provided in EEGLAB [25].”
MethodA Tutorial on Support Vector Machines for Pattern Recognition
Burges, C. J. C. (1998) · Data Mining and Knowledge Discovery · doi:10.1023/a:1009715923555 · Cited by 16,429 · cited 1×
“Analogous to LDA, SVM also maps data upon a hyperplane, whereas it selects the hyperplane that maximizes the margin between different classes [33].”
MethodTHE USE OF MULTIPLE MEASUREMENTS IN TAXONOMIC PROBLEMS
FISHER, R. A. (1936) · Annals of Eugenics · doi:10.1111/j.1469-1809.1936.tb02137.x · Cited by 15,227 · cited 1×
“of data within the same class [29].”
A review of classification algorithms for EEG-based brain–computer interfaces
Lotte, F., Congedo, M., Lécuyer, A., Lamarche, F., & Arnaldi, B. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r01 · Cited by 2,665 · cited 3×
“However, kNN algorithms are known for their sensitivity to curse-of-dimensionality, and are not as widely used in BCI researches as LDA or SVM [31].”
BackgroundMethodInfluentialSoft Microfluidic Assemblies of Sensors, Circuits, and Radios for the Skin
Xu, S., Zhang, Y., Jia, L., Mathewson, K. E., Jang, K.-I., Kim, J., Fu, H., Huang, X., Chava, P., Wang, R., et al. (2014) · Science · doi:10.1126/science.1250169 · Cited by 1,199 · cited 1×
“long-term biometric measurements possible in the real world with their softness and deformability [17], [47].”
BackgroundTask-free MRI predicts individual differences in brain activity during task performance
Tavor, I., Jones, O. P., Mars, R. B., Smith, S. M., Behrens, T. E., & Jbabdi, S. (2016) · Science · doi:10.1126/science.aad8127 · Cited by 726 · cited 1×
“Furthermore, as the spatial distributions of brain activities vary across individuals [48], [49], the NHB BCI might face severe challenges in maintaining robustness across individuals.”
BackgroundImaging human EEG dynamics using independent component analysis
Onton, J., Westerfield, M., Townsend, J., & Makeig, S. (2006) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2006.06.007 · Cited by 673 · cited 1×
“channels [40].”
Estimating alertness from the EEG power spectrum
Jung, T.-P., Makeig, S., Stensmo, M., & Sejnowski, T. J. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.553713 · Cited by 480 · cited 4×
“[27], [28], and have been extended into BCI applications for predicting the human performance in a sustained attention task [3], [5], [27], [28].”
BackgroundInfluentialSelf-citationEEG-based drowsiness estimation for safety driving using independent component analysis
Lin, C.-T., Wu, R.-C., Liang, S.-F., Chao, W.-H., Chen, Y.-J., & Jung, T.-P. (2005) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2005.857555 · Cited by 470 · cited 4×
“[27], [28], and have been extended into BCI applications for predicting the human performance in a sustained attention task [3], [5], [27], [28].”
BackgroundMethodInfluentialSelf-citation
Cited by
Progress in Brain Computer Interface: Challenges and Opportunities
Saha, S., Mamun, K. A., Ahmed, K., Mostafa, R., Naik, G. R., Darvishi, S., Khandoker, A. H., & Baumert, M. (2021) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2021.578875 · Cited by 365
Past, Present, and Future of EEG-Based BCI Applications
Värbu, K., Muhammad, N., & Muhammad, Y. (2022) · Sensors · doi:10.3390/s22093331 · Cited by 321
Multi-channel EEG recordings during a sustained-attention driving task
Cao, Z., Chuang, C.-H., King, J.-K., & Lin, C.-T. (2019) · Scientific Data · doi:10.1038/s41597-019-0027-4 · Cited by 268
Self-citationA Systemic Review of Available Low-Cost EEG Headsets Used for Drowsiness Detection
LaRocco, J., Le, M. D., & Paeng, D.-G. (2020) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2020.553352 · Cited by 187
“Summary In recent years, the number of portable, low-cost EEG-based systems available on the market has increased (Wei et al., 2018).”
BackgroundCui, J., Lan, Z., Sourina, O., & Müller-Wittig, W. (2023) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2022.3147208 · Cited by 181
Metadata
- Authors
- Wei, C.-S., Wang, Y.-T., Lin, C.-T., & Jung, T.-P.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2018-02
- Volume
- 26
- Issue
- 2
- Pages
- 400-406
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2782522902
- Cited by
- 171
- References
- 43
- FWCI
- 9.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.