Proportional Joint-Moment Control for Instantaneously Adaptive Ankle Exoskeleton Assistance
The DOI matches its Crossref record.
Abstract
Lower-limb exoskeletons used to improve free-living mobility for individuals with neuromuscular impairment must be controlled to prescribe assistance that adapts to the diverse locomotor conditions encountered during daily life, including walking at different speeds and across varied terrain. The goal of this paper is to design and establish clinical feasibility of an ankle exoskeleton control strategy that instantly and appropriately adjusts assistance to the changing biomechanical demand during variable walking. To accomplish this goal, we developed a proportional joint-moment control strategy that prescribes assistance as a function of the instantaneous estimate of the ankle joint moment and conducted a laboratory-based feasibility study. Four individuals with neuromotor impairment and one unimpaired individual completed exoskeleton-assisted slow and fast gait transition tasks that involved gait initiation and changing walking speed. We found that the controller was effective in instantaneously prescribing exoskeleton assistance that was proportional to the ankle moment with less than 14% root-mean-square error, on average. We also performed a three-subject pilot investigation to determine the ability of the proportional joint-moment controller to improve walking economy. Evaluated in two individuals with cerebral palsy and one unimpaired individual, metabolic cost of transport improved 17-27% during treadmill and over-ground walking with proportional control compared with wearing the exoskeleton unassisted. These preliminary findings support the continued investigation of proportional joint-moment control for assisting individuals with neuromuscular disabilities during walking in real-world settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Task-agnostic exoskeleton control via biological joint moment estimation
Molinaro, D. D., Scherpereel, K. L., Schonhaut, E. B., Evangelopoulos, G., Shepherd, M. K., & Young, A. J. (2024) · Nature · doi:10.1038/s41586-024-08157-7 · Cited by 107
A versatile knee exoskeleton mitigates quadriceps fatigue in lifting, lowering, and carrying tasks
Divekar, N. V., Thomas, G. C., Yerva, A. R., Frame, H. B., & Gregg, R. D. (2024) · Science Robotics · doi:10.1126/scirobotics.adr8282 · Cited by 52
“For example, ankle torques can be directly estimated from the vertical ground reaction force (GRF) measured from an insole ( 51 ), but dynamic modeling errors and missing GRF components present substantial issues for more proximal joints.”
BackgroundMolinaro, D. D., Park, E. O., & Young, A. J. (2023) · 2023 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra48891.2023.10161286 · Cited by 14
Metadata
- Authors
- Gasparri, G. M., Luque, J., & Lerner, Z. F.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2019-04
- Volume
- 27
- Issue
- 4
- Pages
- 751-759
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2924584623
- Cited by
- 116
- References
- 0
- FWCI
- 3.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Proportional Joint-Moment Control for Instantaneously Adaptive Ankle Exoskeleton Assistance. https://app.cochat.ai/papers/10.1109/tnsre.2019.2905979
- The paper
- Gasparri, G. M., Luque, J., & Lerner, Z. F. (2019). Proportional Joint-Moment Control for Instantaneously Adaptive Ankle Exoskeleton Assistance. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2019.2905979
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.