The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Patient-Specific Single Sensor IoT-Based Wearable Fall Prediction and Detection System
Abstract
Falls in older adults are a major cause of morbidity and mortality and are a key class of preventable injuries. This paper presents a patient-specific (PS) fall prediction and detection prototype system that utilizes a single tri-axial accelerometer attached to the patient's thigh to distinguish between activities of daily living (ADL) and fall events. The proposed system consists of two modes of operation: 1) fast mode for fall predication (FMFP) predicting a fall event (300-700 msec) before occurring and 2) slow mode for fall detection (SMFD) with a 1-sec latency for detecting a fall event. The nonlinear support vector machine classifier (NLSVM)-based FMFP algorithm extracts seven discriminating features for the pre-fall case to identify a fall risk event and alarm the patient. The proposed SMFD algorithm utilizes a Three-cascaded 1-sec sliding frames classification architecture with a linear regression-based offline training to identify a single and optimal threshold for each patient. Fall incidence will trigger an alarming notice to the concern healthcare providers via the Internet. Experiments are performed with 20 different subjects (age above 65 years) and a total number of 100 associated falls and ADL recordings indoors and outdoors. The accuracy of the proposed algorithms is furthermore validated via MobiFall Dataset. FMFP achieves sensitivity and specificity of 97.8% and 99.1%, respectively, while SMFD achieves sensitivity and specificity of 98.6% and 99.3%, respectively, for a total number of 600 measured falls and ADL cases from 77 subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modern Statistics for the Social and Behavioral Sciences
Wilcox, R. (2011) · doi:10.1201/9781466503236 · Cited by 62
Cited by
World guidelines for falls prevention and management for older adults: a global initiative
Montero-Odasso, M., van der Velde, N., Martin, F. C., Petrovic, M., Tan, M. P., Ryg, J., Aguilar-Navarro, S., Alexander, N. B., Becker, C., Blain, H., et al. (2022) · Age and Ageing · doi:10.1093/ageing/afac205 · Cited by 1,756
Wearables and the Internet of Things (IoT), Applications, Opportunities, and Challenges: A Survey
John Dian, F., Vahidnia, R., & Rahmati, A. (2020) · IEEE Access · doi:10.1109/access.2020.2986329 · Cited by 386
Wei, K., Zhang, L., Guo, Y., & Jiang, X. (2020) · IEEE Access · doi:10.1109/access.2020.2971654 · Cited by 107
A Noninvasive Glucose Monitoring SoC Based on Single Wavelength Photoplethysmography
Hina, A., & Saadeh, W. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.2979514 · Cited by 99
Self-citationA Review of Machine Learning and TinyML in Healthcare
Tsoukas, V., Boumpa, E., Giannakas, G., & Kakarountas, A. (2021) · 25th Pan-Hellenic Conference on Informatics · doi:10.1145/3503823.3503836 · Cited by 79
Metadata
- Authors
- Saadeh, W., Butt, S. A., & Altaf, M. A. B.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2019-05
- Volume
- 27
- Issue
- 5
- Pages
- 995-1003
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2938949242
- Cited by
- 166
- References
- 1
- FWCI
- 8.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Patient-Specific Single Sensor IoT-Based Wearable Fall Prediction and Detection System. https://app.cochat.ai/papers/10.1109/tnsre.2019.2911602
- The paper
- Saadeh, W., Butt, S. A., & Altaf, M. A. B. (2019). A Patient-Specific Single Sensor IoT-Based Wearable Fall Prediction and Detection System. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2019.2911602
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.