Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 214

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Transcutaneous Spinal Cord Stimulation Restores Hand and Arm Function After Spinal Cord Injury

Open access
Inanici, Fatma, Brighton, Lorie N., Samejima, Soshi, Hofstetter, Christoph P., Moritz, Chet T. · 2021 · IEEE Transactions on Neural Systems and Rehabilitation Engineering

Abstract

Paralysis of the upper extremity severely restricts independence and quality of life after spinal cord injury. Regaining control of hand and arm movements is the highest treatment priority for people with paralysis, 6-fold higher than restoring walking ability. Nevertheless, current approaches to improve upper extremity function typically do not restore independence. Spinal cord stimulation is an emerging neuromodulation strategy to restore motor function. Recent studies using surgically implanted electrodes demonstrate impressive improvements in voluntary control of standing and stepping. Here we show that transcutaneous electrical stimulation of the spinal cord leads to rapid and sustained recovery of hand and arm function, even after complete paralysis. Notably, the magnitude of these improvements matched or exceeded previously reported results from surgically implanted stimulation. Additionally, muscle spasticity was reduced and autonomic functions including heart rate, thermoregulation, and bladder function improved. Perhaps most striking is that all six participants maintained their gains for at least three to six months beyond stimulation, indicating functional recovery mediated by long-term neuroplasticity. Several participants resumed their hobbies that require fine motor control, such as playing the guitar and oil painting, for the first time in up to 12 years since their injuries. Our findings demonstrate that non-invasive transcutaneous electrical stimulation of the spinal networks restores movement and function of the hands and arm for people with both complete paralysis and long-term spinal cord injury.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tnsre.2021.3049133

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Metadata

Authors
Inanici, F., Brighton, L. N., Samejima, S., Hofstetter, C. P., & Moritz, C. T.
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2021
Volume
29
Pages
310-319
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W3119002792
Cited by
214
References
11
FWCI
19.92
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transcutaneous Spinal Cord Stimulation Restores Hand and Arm Function After Spinal Cord Injury. https://app.cochat.ai/papers/10.1109/tnsre.2021.3049133
The paper
Inanici, F., Brighton, L. N., Samejima, S., Hofstetter, C. P., & Moritz, C. T. (2021). Transcutaneous Spinal Cord Stimulation Restores Hand and Arm Function After Spinal Cord Injury. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2021.3049133

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.